Rugged Outback RS416 manual Technical Specifications, Power Supply Specifications

Page 29

5Technical Specifications

5.1 Power Supply Specifications

 

 

Power Supply

 

Input Range

 

 

 

Type

 

Min

Max

 

 

 

12 – 24 VDC

10 VDC

36 VDC

 

 

 

24 VDC

18 VDC

36 VDC

 

 

 

48 VDC

36 VDC

59 VDC

 

 

 

HI (125/250 VDC) 1

88 VDC

300 VDC

 

 

 

HI (110/230 VAC) 1

85 VAC

265 VAC

 

Table 7: Power Supply Specifications

 

Fuse

 

 

Max. Power Consumption3

 

Rating

 

 

 

 

 

 

 

 

6.3A(F) 2

 

 

 

5A(F)

2

 

15 W

 

2A(T) 2

 

 

 

 

 

2A(T) 1,2

 

 

NOTES:

1.This is the same power supply for both AC and DC.

2.(F) Denotes fast-acting fuse, (T) denotes time-delay fuse

3.Power consumption varies based on configuration. 10/100Tx ports consume roughly 1W less than fiber optic ports

4.For continued protection against risk of fire, replace only with same type and rating of fuse.

5.2Failsafe Relay Contact Ratings

Parameter

Value (Resistive Load)

 

 

Max Switching Voltage

240VAC, 125VDC

Rated Switching Current

2A @ 240VAC

 

0.15A @ 125VDC, 2A @ 30VDC

Max Switching Capacity

150W, 500VA

Table 8: Failsafe Relay Contact Ratings

29

2008 RuggedCom Inc. All rights reserved

Rev104

Image 29
Contents RuggedServer RS416 Trademarks Table of Contents Table of Tables Table of Figures 2008 RuggedCom Inc. All rights reserved Rev104 Functional Overview Feature HighlightsProduct Overview  2008 RuggedCom Inc. All rights reserved Rev104 Colour Description Display Panel DescriptionLEDs Green Solid Link Mode ColourMounting Installation19 Rack Mount Adapters Rack MountingPanel and DIN Rail Mounting RS416 Series PANEL/DIN Rail mounting diagram withRS416 Series Philips Screw Terminal Block Power Supply Wiring and GroundingChassis Ground is connected to the Safety Ground Power source is ACDescription Usage PS1 Live / +AC Power Supply Wiring Examples DC Power supply wiring examples DC Power Supply Wiring ExamplesInstalled within 3m of unit Must be installed and separately identifiedDual Power Supplies Wiring Examples Dielectric Strength Hipot Testing Dielectric Strength Hipot TestingFailsafe Alarm Relay Wiring Failsafe Alarm Relay WiringRS232 over RJ45 console cable pin-out Male RJ45 Console Port WiringFiber Serial Interface Serial PortsDB9 Female DCE Port pin-out 2 RS232/RS485/RS422 via DB9RJ45 Port pin-out No internal termination is provided 3 RS232/RS485/RS422 via RJ45Shield Conceptual recommended RS485 wiring diagram 4 RS485 WiringSerial Port Transient Protection +Rx +Tx No Connection Ethernet PortsCopper Ports Fiber Optic Ports 100FX LC connector 100FX SC connectorEthernet panel LED description Ethernet Panel DescriptionFailsafe Relay Contact Ratings Technical SpecificationsPower Supply Specifications Serial Ports Data Port SpecificationsEthernet Ports  2008 RuggedCom Inc. All rights reserved Rev104 Electrical Safety Levels Comments Type Test SpecificationsType Test Specification Atmospheric Environment 95%Operating Environment Mechanical SpecificationsMechanical Drawing Agency Approvals WarrantyAgency Standards Comments FCC Part 15, Class a Approved