Rugged Outback RS416 manual Operating Environment, Mechanical Specifications

Page 34

5.5 Operating Environment

Parameter

 

Range

Comments

 

 

 

Ambient Temperature as

Ambient Operating

 

 

measured from a 30cm

 

-40 to 85°C

radius surrounding the

Temperature

 

 

 

center of the RS1600

 

 

 

 

 

 

enclosure.

Ambient Relative Humidity

 

5% to 95%

Non-condensing

Ambient Storage

 

-40 to 85°C

 

Temperature

 

 

 

 

 

Table 16: Operating Environment

 

 

5.6 Mechanical Specifications

Parameter

Value

 

Comments

 

18.29 x 10.17 x 1.74 inches

(Length x Width x Height)

Dimensions

with mounting brackets

(464,57) x (258,32) x

(44,20) mm

 

installed

 

 

 

Weight

10 lb (4.5 Kg)

 

Enclosure

18 AWG galvanized steel

 

Table 17: Mechanical Specifications

34

2008 RuggedCom Inc. All rights reserved

Rev104

Image 34
Contents RuggedServer RS416 Trademarks Table of Contents Table of Figures Table of Tables 2008 RuggedCom Inc. All rights reserved Rev104 Product Overview Feature HighlightsFunctional Overview  2008 RuggedCom Inc. All rights reserved Rev104 Display Panel Description Colour DescriptionMode Colour LEDs Green Solid LinkInstallation MountingRack Mounting 19 Rack Mount AdaptersRS416 Series PANEL/DIN Rail mounting diagram with Panel and DIN Rail MountingPower Supply Wiring and Grounding RS416 Series Philips Screw Terminal BlockDescription Usage Power source is ACChassis Ground is connected to the Safety Ground PS1 Live / +AC Power Supply Wiring Examples Installed within 3m of unit DC Power Supply Wiring ExamplesDC Power supply wiring examples Must be installed and separately identifiedDual Power Supplies Wiring Examples Dielectric Strength Hipot Testing Dielectric Strength Hipot TestingFailsafe Alarm Relay Wiring Failsafe Alarm Relay WiringConsole Port Wiring RS232 over RJ45 console cable pin-out Male RJ45Serial Ports Fiber Serial Interface2 RS232/RS485/RS422 via DB9 DB9 Female DCE Port pin-outShield 3 RS232/RS485/RS422 via RJ45RJ45 Port pin-out No internal termination is provided 4 RS485 Wiring Conceptual recommended RS485 wiring diagramSerial Port Transient Protection Copper Ports Ethernet Ports+Rx +Tx No Connection 100FX LC connector 100FX SC connector Fiber Optic PortsEthernet Panel Description Ethernet panel LED descriptionPower Supply Specifications Technical SpecificationsFailsafe Relay Contact Ratings Data Port Specifications Serial PortsEthernet Ports  2008 RuggedCom Inc. All rights reserved Rev104 Type Test Specification Atmospheric Environment Type Test SpecificationsElectrical Safety Levels Comments 95%Mechanical Specifications Operating EnvironmentMechanical Drawing Agency Standards Comments WarrantyAgency Approvals FCC Part 15, Class a Approved