Rugged Outback RS416 manual  2008 RuggedCom Inc. All rights reserved Rev104

Page 7

Integrated Ethernet Switch - 2 or 4 port options

(copper and/or fiber)

High performance and throughput Ethernet switching

Fully IEEE 802.3, IEEE 802.3u, IEEE 802.3x compliance

Non-blocking, store and forward switching

RuggedRated™ for Reliability in Harsh Environments

Immunity to EMI and heavy electrical surges

Meets IEEE 1613 (electric utility substations)

Exceeds IEC 61850-3 (electric utility substations)

Exceeds IEC 61800-3 (variable speed drive systems)

Exceeds IEC 61000-6-2 (generic industrial)

Exceeds NEMA TS-2 (traffic control equipment)

Fully independent 2 kV (RMS) isolated serial ports

-40°C to +85°C operating temperature (no fans)

18 AWG galvanized steel enclosure

Universal Power Supply Options

Fully integrated, dual-redundant (optional) power supplies

Universal high-voltage range: 88-300 VDC or 85-264 VAC

Popular low voltage DC ranges: 12 VDC, 24 VDC, 48 VDC

Terminal blocks for reliable maintenance free connections

CSA/UL 60950 safety approved to +85°C

Rugged Operating System (ROS™) Features

Simple plug and play operation - automatic learning, negotiation, and crossover detection

Integrated Cyber Security features

RSTP (802.1w) and Enhanced Rapid Spanning Tree (eRSTP™) network fault recovery (<5ms)

Quality of Service (802.1p) for real-time traffic

VLAN (802.1q) with double tagging and GVRP support

IGMP Snooping for multicast filtering

Port Rate Limiting and Broadcast Storm Limiting

Port configuration, status, statistics, mirroring, security

Management Tools

Web-based, Telnet, CLI management interfaces

SNMP v1/v2/v3

Remote Monitoring (RMON)

Rich set of diagnostics with logging and alarms

7

2008 RuggedCom Inc. All rights reserved

Rev104

Image 7
Contents RuggedServer RS416 Trademarks Table of Contents Table of Tables Table of Figures 2008 RuggedCom Inc. All rights reserved Rev104 Product Overview Feature HighlightsFunctional Overview  2008 RuggedCom Inc. All rights reserved Rev104 Colour Description Display Panel DescriptionLEDs Green Solid Link Mode ColourMounting Installation19 Rack Mount Adapters Rack MountingPanel and DIN Rail Mounting RS416 Series PANEL/DIN Rail mounting diagram withRS416 Series Philips Screw Terminal Block Power Supply Wiring and GroundingPS1 Live / + Power source is ACChassis Ground is connected to the Safety Ground Description UsageAC Power Supply Wiring Examples Must be installed and separately identified DC Power Supply Wiring ExamplesDC Power supply wiring examples Installed within 3m of unitDual Power Supplies Wiring Examples Dielectric Strength Hipot Testing Dielectric Strength Hipot TestingFailsafe Alarm Relay Wiring Failsafe Alarm Relay WiringRS232 over RJ45 console cable pin-out Male RJ45 Console Port WiringFiber Serial Interface Serial PortsDB9 Female DCE Port pin-out 2 RS232/RS485/RS422 via DB9Shield 3 RS232/RS485/RS422 via RJ45RJ45 Port pin-out No internal termination is provided Conceptual recommended RS485 wiring diagram 4 RS485 WiringSerial Port Transient Protection Copper Ports Ethernet Ports+Rx +Tx No Connection Fiber Optic Ports 100FX LC connector 100FX SC connectorEthernet panel LED description Ethernet Panel DescriptionPower Supply Specifications Technical SpecificationsFailsafe Relay Contact Ratings Serial Ports Data Port SpecificationsEthernet Ports  2008 RuggedCom Inc. All rights reserved Rev104 95% Type Test SpecificationsElectrical Safety Levels Comments Type Test Specification Atmospheric EnvironmentOperating Environment Mechanical SpecificationsMechanical Drawing FCC Part 15, Class a Approved WarrantyAgency Approvals Agency Standards Comments