RuggedCom RS969 manual PS1 Live / + is connected to the positive + terminal if

Page 10

The RS969 family has 2 different power supply input connectors---Mini A-coded male connector or M23 A-code male connector shown in Figure 2.2.1.1. The Mini power connector only has 4 terminals, so only one power supply source is allowed to connect to the RS969 with Mini power connector; The M23 power connector has 5 terminal pins which means 2 power supply sources are allowed to power the RS969 with M23 power connector.

The RS969 family supports dual redundant power supplies – “Power Supply 1 (PS1)” and “Power Supply 2 (PS2)”. The connections for PS1, PS2 are shown in Table1 and 2.

Refer to

Table 1 and 2 for a description of each terminal and sections 2.3.2 through 2.3.4 for wiring examples.

Terminal #

 

 

Description

 

Usage

 

 

 

 

 

 

 

 

 

 

 

 

 

PS1 Live / + is connected to the positive (+) terminal if the

1

 

 

PS1

Live / +

 

power source is DC or to the (Live) terminal if the power

 

 

 

 

 

 

source is AC.

 

 

 

 

 

 

PS1 Neutral / - is connected to the negative (-) terminal if

2

 

 

PS1

Neutral / -

 

the power source is DC or to the (Neutral) terminal if the

 

 

 

 

 

 

power source is AC.

 

 

 

 

 

 

Chassis Ground is connected to the Safety Ground

 

 

 

 

 

 

terminal for AC inputs or the equipment ground bus for DC

 

 

 

Chassis

 

inputs. This terminal 3 is connected to chassis ground

3

 

 

 

internally in the RS969 family. There is also an additional

 

 

Ground

 

 

 

 

 

chassis ground screw and the chassis ground connects to

 

 

 

 

 

 

 

 

 

 

 

 

both power supply surge grounds via a removable jumper

 

 

 

 

 

 

shown in Figure 2.2.1.2 .

4

 

 

 

 

 

PS2 Live / + is connected to the positive (+) terminal if the

 

 

PS2 Live / +

 

power source is DC or to the (Live) terminal if the power

 

 

 

 

 

 

 

 

 

 

source is AC.

5

 

 

 

 

 

PS2 Neutral / - is connected to the negative (-) terminal if

 

 

PS2 Neutral / -

 

the power source is DC or to the (Neutral) terminal if the

 

 

 

 

 

 

 

 

 

 

power source is AC.

Table 1: RS969 Power terminal block connection description for M23 A-code male connector

 

10

2008 RuggedCom Inc. All rights reserved

Rev104

Image 10
Contents RuggedSwitch RS969 Trademarks  2008 RuggedCom Inc. All rights reserved Rev104Table of Contents Product Overview Ethernet PortsRS969 Family Ports/Connectors Description 1 RS969-M12 with Mini-Change Power Connector2 RS969-RJ45 with M23 Power Connector Activity Comments Installation DIN Rail MountingIngress Protection IP67 Ingress of waterPower Supply Wiring and Grounding Mini power supply connector M23 power supply connectorTerminal for AC inputs or the equipment ground bus for DC Both power supply surge grounds via a removable jumperPS1 Live / + is connected to the positive + terminal if Chassis ground screw and the chassis ground connects toTerminal # Description Usage Single AC Power Supply Wiring Examples Single DC Power Supply Wiring Examples Dual Power Supplies DC and AC Inputs DC And AC power supply wiring examples Dielectric Strength Testing Failsafe Alarm Relay Wiring and Specifications Console Port Wiring RS232 over M12 console cable pin-outFast Ethernet Ports Signal Description Pin SignalFailsafe Relay Specifications Technical SpecificationsPower Supply Specifications Operating EnvironmentTwisted Pair Data Port Specifications Fiber Optical Port SpecificationsIEC 61850-3 Type Tests Ieee 1613 Type Tests IEC Environmental Type TestsMechanical Specifications Parameter Value Comments Agency Approvals Agency Standards CommentsPower 1/unit AccessoriesConsole 1/unit Failsafe 1/unit Ethernet 8/unit LC Fiber Optic 2/unit Warranty