RuggedCom RS969 manual Ingress Protection IP67, Ingress of water

Page 8

2.2 Ingress Protection IP67

IEC International Standard 60529 (Edition 2.1: 2001-02) is a "classification of degrees of protection provided by enclosures as a system for specifying the enclosures of electrical equipment on the basis of the degree of protection provided by the enclosure." These ratings are determined by specific tests

The IP number is composed of two numbers, the first referring to the protection against solid objects and the second against liquids. The higher the IP number, the better the protection. The chart below defines levels of IP ratings.

 

1st

 

Degree of protection against access to

 

2nd

 

Degree of protection against the

 

 

 

 

 

IP#

 

hazardous parts & ingress of solid objects

 

IP#

 

ingress of water

0

 

No protection

0

 

No protection

 

 

 

 

 

 

 

 

1

 

Protected against solid foreign objects of 50 mm Ø

1

 

Protected against vertically falling water drops

 

and >

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

Protected against solid foreign objects of 12.5 mm Ø

2

 

Protected against vertically falling water drops

 

and >

 

when enclosure titled up 15°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

Protected against solid foreign objects of 2.5 mm Ø

3

 

Protected against spraying water

 

and >

 

 

 

 

 

 

 

 

4

 

Protected against solid foreign objects of 1.0 mm Ø

4

 

Protected against splashing water

 

and >

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

Dust protected

5

 

Protected against jet-water

 

 

 

 

 

 

6

 

Dust tight

6

 

Protected against strong jet-water

 

 

 

 

 

 

 

 

 

 

 

 

7

 

Protected against the effects of temporary

 

 

 

 

 

submersion in water

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

Protected against the effects of permanent

 

 

 

 

 

submersion in water

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The RuggedCom M969 Industrial Ethernet Switch is manufactured and tested to IP67 standards. With an IP67 rating a product will be "dust tight" and remain completely sealed when immersed in water to a depth of 1 meter for 1 hour. (IEC 60529)

These caps completely seals off unused ports on the IP67 Industrial Ethernet Switch. It has an IP67 rated seal that keeps out all contaminants like dirt, oil, and water.

8

2008 RuggedCom Inc. All rights reserved

Rev104

Image 8
Contents RuggedSwitch RS969 Trademarks  2008 RuggedCom Inc. All rights reserved Rev104Table of Contents Product Overview Ethernet PortsRS969 Family Ports/Connectors Description 1 RS969-M12 with Mini-Change Power Connector2 RS969-RJ45 with M23 Power Connector Activity Comments Installation DIN Rail MountingIngress Protection IP67 Ingress of waterPower Supply Wiring and Grounding Mini power supply connector M23 power supply connectorBoth power supply surge grounds via a removable jumper PS1 Live / + is connected to the positive + terminal ifTerminal for AC inputs or the equipment ground bus for DC Chassis ground screw and the chassis ground connects toTerminal # Description Usage Single AC Power Supply Wiring Examples Single DC Power Supply Wiring Examples Dual Power Supplies DC and AC Inputs DC And AC power supply wiring examples Dielectric Strength Testing Failsafe Alarm Relay Wiring and Specifications Console Port Wiring RS232 over M12 console cable pin-outFast Ethernet Ports Signal Description Pin SignalTechnical Specifications Power Supply SpecificationsFailsafe Relay Specifications Operating EnvironmentTwisted Pair Data Port Specifications Fiber Optical Port SpecificationsIEC 61850-3 Type Tests Ieee 1613 Type Tests IEC Environmental Type TestsMechanical Specifications Parameter Value Comments Agency Approvals Agency Standards CommentsConsole 1/unit AccessoriesPower 1/unit Failsafe 1/unit Ethernet 8/unit LC Fiber Optic 2/unit Warranty