Isolation

Comments

 

 

1500 Vrms

Dielectric test voltage (1 minute) between coil & contacts

3.4 Twisted Pair Data Port Specifications

Data Port

Media

Distance

10/100 Mbps

Cat 5 UTP or STP

100m

 

 

 

Connector Type

RJ45 or M12

3.5 Fiber Optical Port Specifications

For maximum flexibility RuggedCom Inc. offers a number of different transceiver choices for Gigabit fiber optical communications. The following table details fiber optic specifications based on the order code / transceiver selected at time of ordering.

Order Code

2LCMM

2LC10

2LC25

Mode /

Connector

MM/ LC SM / LC SM / LC

Tx λ

Cable

(nm)

Type2

 

 

85050/125

1310 9/125

1310 9/125

Tx Pwr (dBm) 3 (Min/Max)

-9.5 / -4 -9.5 / -3 -5 / 0

Rx

Sensitivity

(dBm) 3

-20 -22 -22

Rx

Saturation

(dBm) 3

0 -3 -3

Typical

Distance1

(km)

0.5

10

25

Power

Budget

(dB)

13

18.5

19.5

NOTES:

1.Maximum segment length is greatly dependent on factors such as fiber quality, and number of patches and splices. Please consult RuggedCom sales associates when determining maximum segment distances.

2.All cabling is duplex type unless otherwise specified.

3.All optical power numbers are listed as dBm averages.

21

2008 RuggedCom Inc. All rights reserved

Rev104

Image 21
Contents RuggedSwitch RS969  2008 RuggedCom Inc. All rights reserved Rev104 TrademarksTable of Contents Ethernet Ports Product Overview1 RS969-M12 with Mini-Change Power Connector RS969 Family Ports/Connectors Description2 RS969-RJ45 with M23 Power Connector Activity Comments DIN Rail Mounting InstallationIngress of water Ingress Protection IP67Mini power supply connector M23 power supply connector Power Supply Wiring and GroundingPS1 Live / + is connected to the positive + terminal if Both power supply surge grounds via a removable jumperTerminal for AC inputs or the equipment ground bus for DC Chassis ground screw and the chassis ground connects toTerminal # Description Usage Single AC Power Supply Wiring Examples Single DC Power Supply Wiring Examples Dual Power Supplies DC and AC Inputs DC And AC power supply wiring examples Dielectric Strength Testing Failsafe Alarm Relay Wiring and Specifications RS232 over M12 console cable pin-out Console Port WiringPin Signal Fast Ethernet Ports Signal DescriptionPower Supply Specifications Technical SpecificationsFailsafe Relay Specifications Operating EnvironmentFiber Optical Port Specifications Twisted Pair Data Port SpecificationsIEC 61850-3 Type Tests IEC Environmental Type Tests Ieee 1613 Type TestsMechanical Specifications Parameter Value Comments Agency Standards Comments Agency ApprovalsAccessories Power 1/unitConsole 1/unit Failsafe 1/unit Ethernet 8/unit LC Fiber Optic 2/unit Warranty