3Com Hub 1000 SX manual Xmodem-CRC To transfer the firmware image file

Page 50
Xmodem-CRC.

A-16APPENDIX A: USING THE CONSOLE PORT

Transferring the Make sure that the terminal-emulation program supports one of Firmware Image File the following file transfer protocols: Xmodem, Xmodem-1K, or

Xmodem-CRC.

To transfer the firmware image file:

1Obtain the file that contains the firmware image from the 3Com World Wide Web site:

http://www.3com.com/

2Copy the file to the PC.

3Connect the console port to the PC. (See “Connecting the Console Port” earlier in this appendix.)

4Log on. (See “Logging On” earlier in this appendix.)

5At the Hub 1000 SX Configuration menu prompt, enter:

3

***************************************************

**Hub 1000 Configuration Menu **

***************************************************

[1]Configure port settings

[2]Display hub status

[3]Update firmware image

[4]Change password

[5]Logout

Enter choice -> 3

The hub enters file transfer mode and prompts you to begin the file transfer.

Please initiate XMODEM transfer now. Press <ESC> to abort.

C

The C character indicates that the hub is waiting for the terminal-emulation program to send a file.

If you want to stop the file transfer at this point, press Esc.

6From the terminal-emulation program, select the appropriate command to send a file using the Xmodem, Xmodem-1K, or Xmodem-CRC protocol.

This command varies, depending on the terminal-emulation program. Some programs call this operation uploading a file.

Image 50
Contents A member of the 3Com SuperStack II System SuperStack II Hub 1000 SXUser Guide 3Com Corporation 5400 Bayfront Plaza Santa Clara, California UNITED STATES GOVERNMENT LEGENDSABOUT THIS GUIDE 1 INTRODUCTION CONTENTS2 INSTALLING THE HUB POST Messages A USING THE CONSOLE PORT3 MAKING CONNECTIONS TECHNICAL SUPPORT SPECIFICATIONSGLOSSARY INDEX 3COM CORPORATION LIMITED WARRANTY FCC CLASS A VERIFICATION STATEMENTPage FIGURES Page TABLES Port Configuration MenuPage Notice Type ABOUT THIS GUIDEIcon DescriptionMenu commands CommandsSETDEFAULT !0 -IP NETaddr = and buttonsGeneral Description INTRODUCTIONHub 1000 SX Full-Duplex Downlinksand Uplink OperationFlow Control Features and FunctionsINSTALLING THE HUB SuperStack II Hub 1000 SX User GuideHub Description The hub’s front and rear panels are shown in Figure Installing and Connecting the Hub4 Repeat steps 2 and 3 for the other side of the hub Maximum Cable ConnectorTable 2-1 Downlink Connections TypeColor Table 2-2 Hub 1000 SX IndicatorsIndicator StatusThe gigabit interface connector GBIC port on the rear panel of the Connecting aGBIC Module Using Optional Power SystemsPower Modules Cabling OptionsA hub connects to a UPS unit through the hub’s AC power cord Table 2-4 Advanced RPS Configuration OptionsYou can connect a UPS unit to an Advanced RPS unit as long as you do not exceed the maximum wattage 325 watts for the UPS unit. To verify that the UPS unit’s maximum wattage is not exceeded, calculate the total power consumption of all units connected to the Advanced RPS. If the result is less than 325 watts, your configuration is safe if the result is greater than 325 watts, then there are too many units connected to the Advanced RPS Page MAKING CONNECTIONS Table 3-1 Gigabit Ethernet Maximum Cable LengthsServers Power WorkgroupAggregating connecting to the network backbone. See FigureYou can use the Hub 1000 SX downlinks to aggregate 10/100 Mbps SwitchesThe Hub 1000 SX does not support bandwidth aggregation trunking Figure 3-3 Aggregated Switches Connection 3-4 CHAPTER 3 MAKING CONNECTIONSThe best use of the hub uplink is as a backbone connection to a 3Com ConnectingFigure 3-4 Mixed Connection Symptom Figure 3-6 Uplink Connection to a 10/100 Mbps SwitchTable 3-2 Troubleshooting Tips SolutionUSING THE CONSOLE PORT Requirements Connecting theWith Power Console PortConnecting the Console Port A-3 from powerTo connect the console port when the hub is disconnected DisconnectedAfter 4 minutes of inactivity, the CLI logs off automatically Logging Onmessage, return the hub to the supplier Changing the PasswordPort Settings ConfiguringTo display the Port Configuration menu Configuring Port Settings Table A-2 Port Configuration MenuA-8 APPENDIX A USING THE CONSOLE PORT Configuring Port Settings and be configured to receive pause frames Configuring Port Settings A-11 matrix, Y indicates yes and n indicates no. See Table A-3 DisplayingHub Status Table A-3 Hub Status InformationDisplaying Hub Status A-13 Restoring the Factory Default Settings A-14 APPENDIX A USING THE CONSOLE PORTentering option Updating theFirmware Image Checking theXmodem-CRC To transfer the firmware image file log in again. To restart the file transfer, repeat steps 6 and during a firmware update, the CLI displays the following messageLogging Off While saving port settings or Table A-4 File Transfer Error MessagesTable A-5 Fatal Error Messages Environmental Operating Ranges SPECIFICATIONSPhysical Dimensions Page TECHNICAL SUPPORT ServicesBoard Service Online Technical1 408 654 Access by Analog ModemAccess by Digital Modem C-2 APPENDIX C TECHNICAL SUPPORTLocal access numbers are available within the following countries Central European HQ Santa Clara, CaliforniaCzech Republic/Slovak 305 261 3266 Miami, FloridaTo obtain an RMA number, call or fax Page GLOSSARY access method Carrier Sense Multiple Access/Collision Detection. Channel accesscable is based on CSMA/CD Carrier Sense Multiple Access/Collision transmission of light signalsflow control IEEEincoming Mbpscontrol. See also asymmetric flow control, flow control, pause frame Numbers SymbolsINDEX Page Switch 9300 3-2, 3-3 Page HARDWARE 3Com Corporation LIMITED WARRANTYSTANDARD WARRANTY SERVICE SOFTWAREGOVERNING LAW FCC CLASS A VERIFICATION STATEMENTLIMITATION OF LIABILITY