TDK J Series JBW specifications JBW75W Type

Page 10

(10/30)

JBW75W Type

SPECIFICATIONS AND STANDARDS

Part No.

 

 

JBW05-15R

JBW12-6R3

JBW15-5R0

JBW24-3R2

Rated output voltage and current

 

5V • 15A

12V • 6.3A

15V • 5.0A

24V • 3.2A

Maximum output power

W

75

75.6

75

76.8

Input conditions

 

 

 

 

 

Input voltage Eac/Edc

V

85 to 265[Rating: 100-240]/120 to 370

 

 

Input frequency

Hz

47 to 66

 

 

 

Input current

A

1.6/0.8max.[100-240V]

 

 

 

Fuse rating

A

3.15

 

 

 

Surge current

A

30/60max.[100-240V]

 

 

 

Leakage current

mA

0.75/0.75max.[AC.100V(DENAN)/240V(UL, IEC)]

 

 

Power factor

 

0.99/0.95typ.[100-240V]

 

 

 

Efficiency

 

%

75/77typ.

78/80typ.

79/81typ.

82/84typ.

 

[100-240V]

[100-240V]

[100-240V]

[100-240V]

 

 

 

 

Output characteristics

 

 

 

 

 

Output voltage Edc

V

5

12

15

24

Voltage variable range Edc

V

4.5 to 5.5

10.8 to 13.2

13.5 to 16.5

21.6 to 26.4

Maximum output current

A

15

6.3

5.0

3.2(Peak4.2)

Overvoltage threshold Edc

V

5.75 to 6.9

13.8 to 16.8

17.2 to 21

27.6 to 33.6

Overcurrent threshold

A

15.8min.

6.6min.

5.2min.

4.4min.

 

 

Source effect

%

0.4max.[Within the input voltage range]

 

 

Voltage

 

Load effect

%

0.8max.[0 to 100% load]

 

 

 

 

Temperature effect

%

1max.[Ambient temperature: –10 to +60°C]

 

 

stability

 

 

 

 

Drift(Time effect)

%

0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]

 

 

 

 

 

 

Recovery

%

±4max.[50 to 100% sudden load change]

 

 

Ripple Ep-p

mV

80

120

120

120

Ripple noise Ep-p

mV

120

150

150

150

Start up time

ms

500max.(400typ.)/250max.(200typ.)[AC.100/240V]

 

 

Hold up time

ms

20typ.[100-240V]

 

 

 

Auxiliary functions

 

 

 

 

 

Indicator display

 

No

 

 

 

Overvoltage protection

 

Voltage shut-down type(Latch).

 

 

Overcurrent protection

 

Rectangular type, automatic recovery.

 

 

Remote ON-OFF

 

No

 

 

 

Remote sensing

 

No

 

 

 

Standards

 

 

 

 

 

 

Safety standards

 

UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.

 

Noise terminal voltage

 

FCC-B, VCCI-B, EN55011-B, EN55022-B meet.

 

 

Input harmonics current requirement

EN61000-3-2

 

 

 

CE marking

 

Planned compliance.

 

 

 

Constructions

 

 

 

 

 

External dimensions

mm

3255222[HWL]

 

 

 

Weight

 

g

290max.

 

 

 

Mounting method

 

Can be attached to 1 side.

 

 

 

Case material

 

CEM3

 

 

 

• All specifications are subject to change without notice.

004-02 / 20070523 / ea122_jbw

Image 10
Contents Series JBW10 to 150W Specifications and Standards JBW10W TypeShapes and Dimensions Terminal DesignationJBW15W Type JBW15W Type JBW30W Type JBW30W Type JBW50W Type TB2 JBW75W Type 11/30 JBW100W Type 13/30 JBW150W Type 15/30 Common Specifications Characteristics, Functions, and ApplicationsBlock Diagrams JBW10W/15W/30W Types JBW50W TypeInstallation Direction Output POWER-AMBIENT TemperaturederatingsInstallations 150W TypeInsulation and Withstand Voltage Tests Ripple Noise Measurement ConditionsSeries Connection for Increasing Output Voltage Other ConditionsAC.100V Type Surge Current AC.100V Type Power Factor AC.200V Type Power FactorAC.100V Type Efficiency AC.200V Type Efficiency AC.200V Type Surge CurrentAC.100V/200V Type -20C Overcurrent Curve AC.100V/200V Type +60C Overcurrent CurveAC.200V Type Hold UP Time AC.100V Type Hold UP TimeAC.200V Type Life of Electrolytic Capacitor Conductive Noise Emission22/30 23/30 24/30 25/30 AC.100/200V Type -20C Hold UP Characteristics 27/30 28/30 29/30 30/30