(10/30)
JBW75W Type
SPECIFICATIONS AND STANDARDS
Part No. |
|
| |||||
Rated output voltage and current |
| 5V • 15A | 12V • 6.3A | 15V • 5.0A | 24V • 3.2A | ||
Maximum output power | W | 75 | 75.6 | 75 | 76.8 | ||
Input conditions |
|
|
|
|
| ||
Input voltage Eac/Edc | V | 85 to 265[Rating: |
|
| |||
Input frequency | Hz | 47 to 66 |
|
|
| ||
Input current | A |
|
|
| |||
Fuse rating | A | 3.15 |
|
|
| ||
Surge current | A |
|
|
| |||
Leakage current | mA | 0.75/0.75max.[AC.100V(DENAN)/240V(UL, IEC)] |
|
| |||
Power factor |
|
|
|
| |||
Efficiency |
| % | 75/77typ. | 78/80typ. | 79/81typ. | 82/84typ. | |
| |||||||
|
|
|
| ||||
Output characteristics |
|
|
|
|
| ||
Output voltage Edc | V | 5 | 12 | 15 | 24 | ||
Voltage variable range Edc | V | 4.5 to 5.5 | 10.8 to 13.2 | 13.5 to 16.5 | 21.6 to 26.4 | ||
Maximum output current | A | 15 | 6.3 | 5.0 | 3.2(Peak4.2) | ||
Overvoltage threshold Edc | V | 5.75 to 6.9 | 13.8 to 16.8 | 17.2 to 21 | 27.6 to 33.6 | ||
Overcurrent threshold | A | 15.8min. | 6.6min. | 5.2min. | 4.4min. | ||
|
| Source effect | % | 0.4max.[Within the input voltage range] |
|
| |
Voltage |
| Load effect | % | 0.8max.[0 to 100% load] |
|
|
|
| Temperature effect | % | 1max.[Ambient temperature: |
|
| ||
stability |
|
|
| ||||
| Drift(Time effect) | % | 0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h] |
| |||
|
|
| |||||
|
| Recovery | % | ±4max.[50 to 100% sudden load change] |
|
| |
Ripple | mV | 80 | 120 | 120 | 120 | ||
Ripple noise | mV | 120 | 150 | 150 | 150 | ||
Start up time | ms | 500max.(400typ.)/250max.(200typ.)[AC.100/240V] |
|
| |||
Hold up time | ms |
|
|
| |||
Auxiliary functions |
|
|
|
|
| ||
Indicator display |
| No |
|
|
| ||
Overvoltage protection |
| Voltage |
|
| |||
Overcurrent protection |
| Rectangular type, automatic recovery. |
|
| |||
Remote |
| No |
|
|
| ||
Remote sensing |
| No |
|
|
| ||
Standards |
|
|
|
|
|
| |
Safety standards |
|
| |||||
Noise terminal voltage |
|
|
| ||||
Input harmonics current requirement |
|
|
| ||||
CE marking |
| Planned compliance. |
|
|
| ||
Constructions |
|
|
|
|
| ||
External dimensions | mm | 32⋅ 55⋅ 222[H⋅ W⋅ L] |
|
|
| ||
Weight |
| g | 290max. |
|
|
| |
Mounting method |
| Can be attached to 1 side. |
|
|
| ||
Case material |
| CEM3 |
|
|
|
• All specifications are subject to change without notice.