TDK J Series JBW Characteristics, Functions, and Applications, JBW50W Type, Common Specifications

Page 16

Characteristics, Functions, and Applications

BLOCK DIAGRAMS

JBW10W/15W/30W TYPES

(16/30)

AC input

L

Input

Input

filter

rectifier

Surge Input

current smoothing

Output rectifying and

+

DC OUT

N

circuit

circuit

limiting circuit circuit

Over-

Power

current

switching

detection

circuit

circuit

 

Drive

circuit

PWM

control circuit

smoothing circuit

Output voltage control circuit

Overvoltage protection

JBW50W TYPE

L

AC input

Surge current

Input filter

Input

Boost-up

smoothing

Output rectifying and

+

DC OUT

N

limiting circuit

circuit

circuit

circuit

PFC control circuit

Over-

 

Power

current

 

 

switching

detection

 

 

circuit

circuit

 

 

 

 

 

 

Drive circuit

Control circuit

smoothing circuit

Overvoltage detection circuit

Output voltage control circuit

COMMON SPECIFICATIONS

Temperature and humidity

 

Operating(°C)

–10 to +60

Temperature range

Operating available(°C)

–20 to –10

 

Storage(°C)

–30 to +75

Humidity range

Operating(%)RH

10 to 90[Maximum wet-bulb temperature: 35°C, without dewing]

Storage(%)RH

 

 

Vibration and shock

 

 

Vibration

5 to 10Hz

All amplitude 10mm[3 directions, each 1h]

10 to 200Hz

Acceleration 19.6m/s2 (2G)[3 directions, each 1h]

 

Shock

Acceleration

10 to 50W: 588m/s2 (60G)[3 directions, each 3 times]/75 to 150W: 588m/s2(60G)[Sine wave]

Pulse duration

11±5ms

 

Withstand voltage and insulation resistance

 

 

Input terminal to ground terminal(G)

Eac: 2kV, 1min[Normal temperature, normal humidity, cutout current 10mA]

Withstand voltage

Input terminal to output terminal

Eac: 3kV, 1min[Normal temperature, normal humidity, cutout current 10mA]

 

Output terminal to ground terminal(G)

Eac: 500V, 1min[Normal temperature, normal humidity, cutout current 10mA]

 

Input terminal to ground terminal(G)

 

Insulation resistance

Input terminal to output terminal

Eac: 500V, 100Mmin.[Normal temperature, normal humidity]

Output terminal to ground terminal(G)

• All specifications are subject to change without notice.

004-02 / 20070523 / ea122_jbw

Image 16
Contents Series JBW10 to 150W Specifications and Standards JBW10W TypeShapes and Dimensions Terminal DesignationJBW15W Type JBW15W Type JBW30W Type JBW30W Type JBW50W Type TB2 JBW75W Type 11/30 JBW100W Type 13/30 JBW150W Type 15/30 Characteristics, Functions, and Applications Block Diagrams JBW10W/15W/30W TypesCommon Specifications JBW50W TypeOutput POWER-AMBIENT Temperaturederatings InstallationsInstallation Direction 150W TypeRipple Noise Measurement Conditions Series Connection for Increasing Output VoltageInsulation and Withstand Voltage Tests Other ConditionsAC.100V Type Power Factor AC.200V Type Power Factor AC.100V Type Efficiency AC.200V Type EfficiencyAC.100V Type Surge Current AC.200V Type Surge CurrentAC.100V/200V Type -20C Overcurrent Curve AC.100V/200V Type +60C Overcurrent CurveAC.100V Type Hold UP Time AC.200V Type Life of Electrolytic CapacitorAC.200V Type Hold UP Time Conductive Noise Emission22/30 23/30 24/30 25/30 AC.100/200V Type -20C Hold UP Characteristics 27/30 28/30 29/30 30/30