TDK J Series JBW specifications AC.100V/200V Type -20C Overcurrent Curve

Page 20

 

(20/30)

 

 

 

 

 

 

 

 

 

 

 

 

Characteristics, Functions, and Applications

 

 

 

JBW10W TYPE TYPICAL CHARACTERISTICS: JBW05-2R0

 

 

 

AC.100/200V TYPE: –20°C START UP CHARACTERISTICS

AC.100/200V TYPE: +60°C START UP CHARACTERISTICS

AC.265V

AC.265V

AC.85V

AC.85V

 

H : 50ms/Div

H : 50ms/Div

AC.100/200V TYPE: –20°C HOLD UP CHARACTERISTICS

AC.100/200V TYPE: +60°C HOLD UP CHARACTERISTICS

Off

240V

100V

85V

H : 10ms/Div

AC.100V/200V TYPE: –20°C OVERCURRENT CURVE

Off

170V

100V

85V

H : 10ms/Div

AC.100V/200V TYPE: +60°C OVERCURRENT CURVE

 

6

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

AC.85V

 

 

 

 

voltage(V)

4

 

AC.132V

 

 

AC.170V

 

 

 

 

 

 

3

 

 

 

 

AC.265V

 

 

 

 

 

 

 

Output

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

0

1

2

3

4

5

6

 

 

 

Load current(A)

 

 

 

 

6

 

 

 

 

 

 

 

5

AC.85V

 

 

 

AC.265V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

voltage(V)

4

AC.132V

 

 

 

AC.170V

 

 

 

 

 

 

 

3

 

 

 

 

 

 

Output

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

0

1

2

3

4

5

6

 

 

 

 

Load current(A)

 

 

 

• All specifications are subject to change without notice.

004-02 / 20070523 / ea122_jbw

Image 20
Contents Series JBW10 to 150W Specifications and Standards JBW10W TypeShapes and Dimensions Terminal DesignationJBW15W Type JBW15W Type JBW30W Type JBW30W Type JBW50W Type TB2 JBW75W Type 11/30 JBW100W Type 13/30 JBW150W Type 15/30 Characteristics, Functions, and Applications Block Diagrams JBW10W/15W/30W TypesCommon Specifications JBW50W TypeOutput POWER-AMBIENT Temperaturederatings InstallationsInstallation Direction 150W TypeRipple Noise Measurement Conditions Series Connection for Increasing Output VoltageInsulation and Withstand Voltage Tests Other ConditionsAC.100V Type Power Factor AC.200V Type Power Factor AC.100V Type Efficiency AC.200V Type EfficiencyAC.100V Type Surge Current AC.200V Type Surge CurrentAC.100V/200V Type -20C Overcurrent Curve AC.100V/200V Type +60C Overcurrent CurveAC.100V Type Hold UP Time AC.200V Type Life of Electrolytic CapacitorAC.200V Type Hold UP Time Conductive Noise Emission22/30 23/30 24/30 25/30 AC.100/200V Type -20C Hold UP Characteristics 27/30 28/30 29/30 30/30