(8/30)
JBW50W Type
SPECIFICATIONS AND STANDARDS
Part No. |
|
|
| |||||
Rated output voltage and current∗1 | 5V • 10A |
| 12V • 4.3A | 15V • 3.5A | 24V • 2.1A | |||
Maximum output power | W | 50 |
| 51.6 | 52.5 | 50.4 | ||
Input conditions |
|
|
|
|
|
| ||
Input voltage Eac/Edc∗2 | V | 85 to 265[Rating: 100 to 240]/120 to 375 |
|
| ||||
Input frequency | Hz | 47 to 66[Rating: 50 to 60](Single phase) |
|
| ||||
Input current | A | 0.7typ./0.88max. [AC.100V]0.35typ./0.5max.[AC.240V] |
|
| ||||
Fuse rating | A | 3.15[AC.250V, |
|
|
| |||
Surge current | A | 15typ.(30max.)[AC.100V]40typ.(60max.)[AC.240V] cold start |
| |||||
Leakage current | mA | 0.35typ./0.75max.[AC.100V, 60Hz]0.5typ./0.75max.[AC.240V, 60Hz] |
| |||||
Power factor |
| 0.99typ./0.93typ.[AC.100/240V] |
|
| ||||
Efficiency |
| % | 77typ.[AC.100V] |
| 80typ.[AC.100V] | 80typ.[AC.100V] | 81typ.[AC.100V] | |
| % | 79typ.[AC.240V] |
| 81typ.[AC.240V] | 81typ.[AC.240V] | 83typ.[AC.240V] | ||
|
|
|
| |||||
Output characteristics |
|
|
|
|
|
| ||
Output voltage Edc | V | 5 |
| 12 | 15 | 24 | ||
Voltage variable range Edc | V | 4.5 to 5.5 |
| 10.8 to 13.2 | 13.5 to 16.5 | 21.6 to 26.4 | ||
Maximum output current | A | 10 |
| 4.3 | 3.5 | 2.1 | ||
Minimum output current | A | 0 |
| 0 | 0 | 0 | ||
Overvoltage threshold Edc | V | 5.75 to 6.9 |
| 13.8 to 16.8 | 17.2 to 21 | 27.6 to 33.6 | ||
Overcurrent threshold | A | 10.5min. |
| 5.4min. | 4.4min. | 2.7min. | ||
|
| Source effect | % | 0.4max.[Within the input voltage range] |
|
| ||
Voltage |
| Load effect | % | 0.8max.[0 to 100% load] |
|
|
| |
| Temperature effect | % | 1max.[Ambient temperature: |
|
| |||
stability |
|
|
| |||||
| Drift(Time effect) | % | 0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h] |
| ||||
|
|
| ||||||
|
| Recovery | % | ±4max.[50 to 100% sudden load change] |
|
| ||
Ripple | mV | 80max. |
| 120max. | 120max. | 120max. | ||
Ripple noise | mV | 120max. |
| 150max. | 150max. | 150max. | ||
Start up time | ms | 500max.(400typ.)/500max.(400typ.) [AC.100/240V] |
|
| ||||
Hold up time | ms | 20typ./20typ. [AC.100/240V] |
|
|
| |||
Auxiliary functions |
|
|
|
|
|
| ||
Indicator display |
| No |
|
|
| |||
Overvoltage protection |
| Voltage |
|
|
| |||
Overcurrent protection |
| Rectangular type, automatic recovery. |
|
| ||||
Remote |
| No |
|
|
| |||
Remote sensing |
| No |
|
|
| |||
Parallel operation |
| Impossible |
|
|
| |||
Series operation |
| Possible |
|
|
| |||
Output voltage external variable function | No |
|
|
| ||||
Standards |
|
|
|
|
|
|
| |
Safety standards |
|
| ||||||
Noise terminal voltage |
|
|
| |||||
Input harmonics current requirement |
|
|
| |||||
Constructions |
|
|
|
|
|
| ||
External dimensions | mm | 26⋅ 55⋅ 190[H⋅ W⋅ L] |
|
|
| |||
Weight |
| g | 220max. |
|
|
| ||
Mounting method |
| Can be attached to 1 side. |
|
|
| |||
Case material |
| No(PWB Material: CEM3) |
|
|
|
∗1 Current rating(maximum output current) is determined for
∗2 Please note that the deterioration of parts is occasionally caused when operating for a long time(over 10 minutes) with the voltage below the range of the input voltage.
• Optional input, output cable kits are available at a separate price.
• All specifications are subject to change without notice.