(14/30)
JBW150W Type
SPECIFICATIONS AND STANDARDS
Part No. |
|
|
|
| ||||||
Rated output voltage and current∗ |
| 5V • 30A |
| 12V • 12A | 15V • 10A | 24V • 6.3A | 48V • 3.2A | |||
Maximum output power |
| W | 150 |
| 150 | 150 | 151.2 | 153.6 | ||
Input conditions |
|
|
|
|
|
|
| |||
Input voltage Eac/Edc |
| V | 85 to 265[Rating: |
|
|
| ||||
Input frequency |
| Hz | 47 to 66 |
|
|
|
| |||
Input current |
| A |
|
|
| |||||
Surge current |
| A |
|
|
|
| ||||
Leakage current |
| mA | 0.75/0.75max.[AC.100V(DENAN)/240V(UL, IEC)] |
|
| |||||
Power factor |
|
|
|
| ||||||
Efficiency |
|
| % | 78/80typ. |
| 81/83typ. | 81/83typ. | 82/84typ. | 82/84typ. | |
|
|
| ||||||||
|
|
|
|
|
| |||||
Output characteristics |
|
|
|
|
|
|
| |||
Output voltage Edc |
| V | 5 |
| 12 | 15 | 24 | 48 | ||
Voltage variable range Edc |
| V | 4.5 to 5.5 |
| 10.8 to 13.2 | 13.5 to 16.5 | 21.6 to 26.4 | 43.2 to 52.8 | ||
Maximum output current |
| A | 30 |
| 12.5 | 10 | 6.3(Peak7.5) | 3.2 | ||
Overvoltage threshold Edc |
| V | 5.75 to 6.9 |
| 13.8 to 16.8 | 17.2 to 21 | 27.6 to 33.6 | 55.2 to 67.2 | ||
Overcurrent threshold |
| A | 31.5min. |
| 15.7min. | 12.5min. | 7.87min. | 3.36min. | ||
|
| Source effect |
| % | 0.4max.[Within the input voltage range] |
|
|
| ||
Voltage |
| Load effect |
| % | 0.8max.[0 to 100% load] |
|
|
| ||
| Temperature effect |
| % | 1max.[Ambient temperature: |
|
|
| |||
stability |
|
|
|
|
| |||||
| Drift(Time effect) |
| % | 0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h] |
| |||||
|
|
|
| |||||||
|
| Recovery |
| % | ±4max.[50 to 100% sudden load change] |
|
|
| ||
Ripple |
| mV | 80max. |
| 120max. | 120max. | 120max. | 150max. | ||
Ripple noise |
| mV | 120max. |
| 150max. | 150max. | 150max. | 350max. | ||
Start up time |
| ms | 500max.(400typ.)/500max.(300typ.)[AC.100/240V] |
|
| |||||
Hold up time |
| ms | 25/35typ.[AC.100/240V] |
|
|
| ||||
Auxiliary functions |
|
|
|
|
|
|
| |||
Indicator display |
| No |
|
|
|
| ||||
Overvoltage protection |
| Voltage |
|
|
| |||||
Overcurrent protection |
| Rectangular type, automatic recovery. |
|
|
| |||||
Remote |
| No |
|
|
|
| ||||
Remote sensing |
| No |
|
|
|
| ||||
Standards |
|
|
|
|
|
|
|
|
| |
Safety standards |
|
| ||||||||
Noise terminal voltage |
|
|
| |||||||
Input harmonics current requirement |
|
|
|
| ||||||
CE marking |
| Meet. |
|
|
|
| ||||
Constructions |
|
|
|
|
|
|
| |||
External dimensions |
| mm | 40⋅ 75⋅ 222[H⋅ W⋅ L] |
|
|
|
| |||
Weight |
|
| g | 550max. |
|
|
|
| ||
Mounting method |
| Can be attached to 1 side. |
|
|
| |||||
Case metal |
| FR4 |
|
|
|
|
∗Current rating(maximum output current) is determined for
• All specifications are subject to change without notice.