(2/30)
JBW10W Type
SPECIFICATIONS AND STANDARDS
Part No. |
|
|
|
| |||||
Rated output voltage and current∗ |
| 5V • 2A |
| 12V • 0.9A | 15V • 0.7A | 24V • 0.5A | |||
Maximum output power |
| W | 10 |
| 10.8 | 10.5 | 12 | ||
Input conditions |
|
|
|
|
|
| |||
Input voltage Eac/Edc |
| V | 85 to 265[Rating: 100 to 240]/110 to 370 |
|
| ||||
Input frequency |
| Hz | 47 to 440[Rating: 50 to 60](Single phase) |
|
| ||||
Input current |
| A | 0.25typ./0.35max. [AC.100V]0.15typ./0.25max.[AC.240V] |
| |||||
Fuse rating |
| A | 2[AC.250V, |
|
|
| |||
Surge current |
| A | 15typ.(20max.)[AC.100V]30typ.(40max.)[AC.240V] 1st surge current, cold start, reset after 1s minimum. | ||||||
Leakage current |
| mA | 0.1typ./0.75max.[AC.100V, 60Hz]0.15typ./0.75max.[AC.240V, 60Hz] |
| |||||
Power factor |
| 0.6typ./0.45typ.[AC.100/240V] |
|
| |||||
Efficiency |
|
| % | 71typ.[AC.100V] |
| 78typ.[AC.100V] | 79typ.[AC.100V] | 82typ.[AC.100V] | |
|
| % | 71typ.[AC.240V] |
| 79typ.[AC.240V] | 80typ.[AC.240V] | 83typ.[AC.240V] | ||
|
|
|
|
| |||||
Output characteristics |
|
|
|
|
|
| |||
Output voltage Edc |
| V | 5 |
| 12 | 15 | 24 | ||
Voltage variable range Edc |
| V | Fixed |
| Fixed | Fixed | Fixed | ||
Maximum output current |
| A | 2 |
| 0.9 | 0.7 | 0.5 | ||
Minimum output current |
| A | 0 |
| 0 | 0 | 0 | ||
Overvoltage threshold Edc |
| V | 5.75min. |
| 13.8min. | 17.25min. | 27.6min. | ||
Overcurrent threshold |
| A | 2.5min. |
| 1.12min. | 0.87min. | 0.62min. | ||
|
| Source effect |
| % | 0.4max.[Within the input voltage range] |
|
| ||
Voltage |
| Load effect |
| % | 0.8max.[0 to 100% load] |
|
|
| |
| Temperature effect |
| % | 1max.[Ambient temperature: |
|
| |||
stability |
|
|
|
| |||||
| Drift(Time effect) |
| % | 0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h] |
| ||||
|
|
|
| ||||||
|
| Recovery |
| % | ±4max.[50 to 100% sudden load change] |
|
| ||
Ripple |
| mV | 80max. |
| 120max. | 120max. | 120max. | ||
Ripple noise |
| mV | 120max. |
| 150max. | 150max. | 150max. | ||
Start up time |
| ms | 700max.(200typ.)/700max.(200typ.) [AC.100/240V] |
|
| ||||
Hold up time |
| ms | 15typ/140typ [AC.100/240V] |
|
|
| |||
Auxiliary functions |
|
|
|
|
|
| |||
Indicator display |
| No |
|
|
| ||||
Overvoltage protection |
| Zenor diode clamp method, output may latch up depending on the condition. |
| ||||||
Overcurrent protection |
| Fold back type, automatic recovery. |
|
| |||||
Remote |
| No |
|
|
| ||||
Remote sensing |
| No |
|
|
| ||||
Parallel operation |
| Impossible |
|
|
| ||||
Series operation |
| Inpossible |
|
|
| ||||
Output voltage external variable function | No |
|
|
| |||||
Standards |
|
|
|
|
|
|
|
| |
Safety standards |
|
| |||||||
Noise terminal voltage |
|
|
| ||||||
Input harmonics current requirement | No |
|
|
| |||||
Constructions |
|
|
|
|
|
| |||
External dimensions |
| mm | 21⋅ 36⋅ 95[H⋅ W⋅ L] |
|
|
| |||
Weight |
|
| g | 50max. |
|
|
| ||
Mounting method |
| Can be attached to 1 side. |
|
|
| ||||
Case material |
| No(PWB Material: CEM3) |
|
|
|
∗Current rating(maximum output current) is determined for
• Optional input, output cable kits are available at a separate price.
• All specifications are subject to change without notice.