SUPER MICRO Computer X8DTU-6F+-LR, X8DTU-6TF+ manual UIO Power Connector, SAS BBU Connector

Page 58

X8DTU-6F+/X8DTU-6TF+/X8DTU-6(T)F+-LR User's Manual

UIO Power Connector

A Universal I/O Power (UIOP) connector is located next to the UID switch. Connect this header to the power supply to provide ad- equate power to the UIO device installed on the I/O slot for the device to function properly. See the layout below for the location.

SAS BBU Connector

A SAS Battery-Backup Unit (BBU) Connector (J120) is located above the SAS ports on the motherboard. In the event of a power outage, the BBU unit will provide backup power for SAS connection use. See the layout below for the location.

(SAS BBU Part#: BTR-0018L-0000-LSI)

Universal I/O Power Header

Pin Definitions

Pins#

Definition

 

Pin #

Definition

B1

+5V

 

A1

+3.3V

 

B2

+5V

 

A2

+3.3V

 

B3

+5V

 

A3

+3.3V

 

B4

+5V

 

A4

+3.3V

 

B5

+5V

 

A5

+3.3V

 

B6

+5V

 

A6

+3.3V

 

B7

+5V

 

A7

+3.3V

 

B8

+5V

 

A8

+3.3V

 

B9

+5V

 

A9

+3.3V

 

B10

+5V

 

A10

+3.3V

 

B11

-12V

 

A11

+3.3V

 

Key

 

 

Key

 

 

 

 

B12

+3.3VSb

 

A12

+3.3V

 

B13

+3.3VSb

 

A13

+12V

 

B14

GND

 

A14

+12V

 

B15

GND

 

A15

+12V

 

 

 

 

 

 

B16

GND

 

A16

+12V

B17

GND

 

A17

+12V

B18

GND

 

A 18

GND

 

 

 

 

 

A

LED2

 

LED7

LAN2

LAN1

 

USB0/1

KB/MOUSE

UID

 

(10GbLAN2)

TLAN2

(10GbLAN1)

TLAN1

VGA

COM1

 

UIOP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IPMI_LAN

 

A. UIO Power Connector B. SAS Battery-Backup Unit

B

SAS BBU

J120

SAS0~3

SAS

CTRL

LED6 LSI 2108

LED5LED4

JPS1

J2: PCI-E 2.0 X16

J1: PCI-E 2.0 X4 (in X16)

Intel 82599

JPL1

10 Gb LAN 1/2

 

CTRL

 

JPTLAN

 

CPU1

Intel 82576

LAN 1/2

CTRL

FAN8/CPU1

P1-DIMM1C

P1-DIMM1B

P1-DIMM1A

PHY

SP1

P1-DIMM2A P1-DIMM2B P1-DIMM2C

Battery

P1-DIMM3A P1-DIMM3B P1-DIMM3C

JI2C1

LED3

JWD1

JI2C2

JPG1

BMC

CTRL

X8DTU-6F+

TPM

JBT1

Intel

 

 

 

 

ICH 10R

BIOS

COM2

 

 

I-SATA0

 

USB6

I-SATA2

 

 

I-SATA1

 

JL1

I-SATA3

 

USB4/5

I-SATA4

 

JWF1 USB7

 

I-SATA5

 

 

T-SGPIO2 T-SGPIO1

FAN6

Intel

IOH 36D

P2-DIMM3A

P2-DIMM3C P2-DIMM3B

P2-DIMM2A

P2-DIMM2B

P2-DIMM1B P2-DIMM1A P2-DIMM2C

P2-DIMM1C

LED1

JOH1

FAN4 FAN5

IPMB

 

JF1

 

 

 

FAN3

 

CPU2

 

 

 

 

 

 

JPW1

FAN2

FAN7/CPU2

JPI2C1

FAN1

JPW3 JPW2

3-32

Image 58
Contents X8DTU-6F+ X8DTU-6TF+ X8DTU-6F+-LR X8DTU-6TF+-LR Page Preface About This Motherboard Manual OrganizationConventions Used in the Manual Europe Contacting SupermicroHeadquarters Asia-PacificTable of Contents Vii Troubleshooting Main SetupInstalling the CPU Installing the Passive CPU HeatsinkInstalling the Memory Modules Installing the I/O ShieldInstalling the Motherboard Connecting the Power SupplyInstalling Internal Peripherals Installing External PeripheralsChecklist OverviewMotherboard Image X8DTU-6F+ Motherboard LayoutX8DTU-6F+ X8DTU-6F+/X8DTU-6TF+/X8DTU-6TF+-LR Connectors Jumper Description Default SettingX8DTU-6F+/X8DTU-6TF+/X8DTU-6TF+-LR Jumpers X8DTU-6F+/X8DTU-6TF+/X8DTU-6TF+-LR LED Indicators Description State StatusMotherboard Features CPUChipset Bios System Block Diagram Overview Special Features PC Health MonitoringPower Supply Acpi FeaturesSlow Blinking LED for Suspend-State Indicator Overview of the Nuvoton WPCM450 Controller Super I/OInstallation Processor and Heatsink Installation Installing an LGA 1366 ProcessorPage Installing a Passive CPU Heatsink Removing the Passive Heatsink Installing an Active Heatsink Removing the Active Heatsink Installing & Removing DIMMs Installing and Removing the Memory ModulesRemoving Memory Modules Memory Support P1-DIMMs To Populate P1-DIMMs BranchP2-DIMMs To Populate P2-DIMMs Branch CPU 1 To Populate P1-DIMMs CPU 2 To Populate P2-DIMMs Branch35V DIMMs 35V Rdimm Population for the Motherboard w/5600 ProcessorsPossible System Memory Allocation & Availability TsegTools Needed Motherboard InstallationLocation of Mounting Holes Installing the Motherboard Back Panel Connectors/I/O Ports Control Panel Connectors/I/O PortsBack Panel I/O Port Locations and Definitions Keyboard Purple Mouse Green ATX PS/2 Keyboard and PS/2 Mouse PortsPS/2 Keyboard/Mouse Pin Definitions Backplane USB USB 0/1 Universal Serial Bus USBBackpanel USB Front Panel USB 4/5 Type a USBCOM1 COM2 VGA Video ConnectorSerial Ports Serial COM Ports Pin Definitions10Gb Tlan Ports and SFP+ Devices X8DTU-6TF+ Gigabit Ethernet PortsLAN Ports Pin Definition FP UID Switch Unit Identifier SwitchesRear UID Switch Rear UID LED LEDJF1 Header Pins Front Control PanelFront Control Panel Pin Definitions Power LEDPower LED Pin Definitions JF1 NMI ButtonFP UID Switch NIC1 Link LED NIC1 Activity LED HDD/FP UID SwitchNIC1 LED Indicator HDD/UID Switch Pin Definitions JF1OH/Fan Fail/ PWR Fail/BlueUID LED Pin Definitions JF1 NIC2 LED IndicatorOverheat OH/Fan Fail/PWR Fail OH/Fan Fail/PWR Fail LED StatusPWR Fail LED Reset Button Power Fail LEDReset Button Reset Button Pin Definitions JF1Power Button Pin Definitions JF1 Power ButtonPWR Button Pin ATX PWR Reqd Connecting CablesPower Connectors 8-pin Processor PWRFan Headers Chassis IntrusionInternal Buzzer SP1 Pin Definition Internal SpeakerInternal Speaker Buzzer Ipmb Header Pin DefinitionsOverheat LED DOM Power ConnectorOverheat LED/Fan Fail Overheat LED Pin DefinitionsPower SMB I2C Connector Sgpio 1/2 HeadersUIO Power Connector B. SAS Battery-Backup Unit UIO Power ConnectorSAS BBU Connector Universal I/O Power Header Pin DefinitionsTrusted Platform Module Header TPM ConnectorTrusted Platform Module TPM Header Pin Definitions Glan Ports 1/2 Enable Tlan Ports 1/2 Enable X8DTU- 6TF+ Jumper SettingsGlan and Tlan Enable Explanation of JumpersWatch Dog Jumper Settings Watch Dog Enable/DisableClear Cmos Watch Dog Enable Cmos ClearVGA Enable VGA EnableI2C for PCI/PCI-E slots Jumper Settings I2C Bus to PCI-Exp. SlotsSAS Enable SAS Enable Jumper SettingsGlan 1/2 LEDs Onboard LED IndicatorsRear View when facing the rear side of the chassis Ipmi Dedicated LAN LEDs10GbLAN LED X8DTU-6TF+ Onboard Power LEDOnboard PWR LED BMC Heartbeat LED Rear UID LEDBMC Heartbeat LED BMC Heartbeat LED LED StateSAS Activity & SAS Heartbeat LEDs SAS Error LEDSAS Error LED LED Status SAS Activity & SAS Heartbeat LEDs LED StatusSerial ATA Ports Serial ATA Sata and Serial Attached Scsi SAS ConnectionsSAS Ports Before Power On Troubleshooting ProceduresNo Power Losing the System’s Setup Configuration System Boot FailureNo Video Memory Errors When the System Becomes UnstableTechnical Support Procedures Frequently Asked Questions Question How do I update my BIOS?Question How do I handle the used battery? Returning Merchandise for ServiceQuestion Whats on the CD that came with my motherboard? Starting Bios Setup Utility IntroductionHow To Change the Configuration Data Main SetupStarting the Setup Utility Processor System Time/System DateSuperMicro X8DTU-6TF+ System MemoryAdvanced Setup Configurations Boot FeaturesProcessor and Clock Options Page Active Processor Cores Intel AES-NI Available when supported by the OS and the CPUMPS and Acpi Madt Ordering Intel Eist TechnologyAdvanced Chipset Control QPI and IMC ConfigurationQPI L0s and L1 Request Transaction IDQPI Quick Path Interconnect Links Speed Memory FrequencyNorth Bridge Chipset Configuration South Bridge Configuration IDE/SATA Configuration LBA/Large Mode Ahci Codebase Available when RAID or Ahci is selectedIDE Detect Timeout sec TypeDMA Mode PIO ModePIO Mode Select Options DMA Mode Select OptionsPCI/PnP Configuration Remote Access Configuration Super IO Device ConfigurationHardware Health Monitor CPU 1 Temperature/CPU 2 Temperature/System Temperature CPU Overheat AlarmCPU1 Temperature/CPU2 Temperature Fan 1 ~ Fan 8 Reading Fan Speed Control ModesACPI Configuration Whea Support Intel Txtlt ConfigurationIntel TXT Initialization Trusted Computing Optional Ipmi Firmware Version IPMI ConfigurationView BMC System Event Log Status of BMCClear BMC System Event Log Clear BMC System Log now Subnet Mask When IP Address Source is set to StaticSet LAN Configuration IP Address SourceEvent Log Configuration Supervisor Password Security SettingsMemory ECC Error Log User PasswordChange User Password Boot ConfigurationBoot Device Priority Password CheckExit Options Save Changes and Exit Load Optimal DefaultsLoad Fail-Safe Defaults Discard Changes and ExitX8DTU-6F+/X8DTU-6TF+/X8DTU-6TF+-LR Motherboard User’s Manual Error Message Bios Error Beep CodesBeep Code Page Installing Software Programs Driver/Tool Installation Display ScreenConfiguring Supero Doctor Supero Doctor III Interface Display Screen-II Remote Control