SUPER MICRO Computer X8DTU-6F+-LR, X8DTU-6TF+-LR manual 35V DIMMs

Page 37

Chapter 3: Installation

Memory Support for the Motherboard with the 5600 Processor(s) Installed

1.5V DIMMs

1.5V RDIMM Population for the Motherboard w/5600 Processors Installed

DIMM

DIMMs

DIMM Type

Speeds (in MHz)

Ranks per DIMM

Slots per

Populated

(Reg.=Registered)

 

(any combination;

Channel

per Channel

 

 

SR=Single Rank,

 

 

 

 

DR=Dual Rank,

 

 

 

 

QR=Quad Rank)

3

1

Reg. DDR3 ECC

800,1066,1333

SR or DR

3

1

Reg. DDR3 ECC

800,1066 (Note 1)

QR

3

2

Reg. DDR3 ECC

800,1066, 1333

Mixing SR, DR

3

2

Reg. DDR3 ECC

800 (Note 2)

Mixing SR, DR, QR

 

 

 

 

 

3

3

Reg. DDR3 ECC

800 (Note 2)

Mixing SR, DR

 

 

 

 

 

Note 1: 1333 MHz RDIMMs will run at 1066 MHz (-BIOS automatic downgrading).

Note 2: 1333/1066 MHz RDIMMs will run at 800 MHz (-BIOS automatic downgrading).

Note 3: MIxing of 1.35V and 1.5V DIMMs is not recommended.

1.5V LRDIMM Population for the Motherboard w/5600 Processors

Installed (for X8DTU-6F+-LR and 8XDTU-6TF+-LR Only)

DIMM

DIMMs

DIMM Type

Speeds (in MHz)

Ranks per DIMM (QR=Quad

Slots per

Populated

(LR= Load

 

Rank, OR=Octal Rank)

Channel

per Channel

Reduced)

 

 

 

 

 

 

 

3

1

LR DDR3 ECC

1066

QR or OR

 

 

 

 

 

3

2

LR DDR3 ECC

1066

QR or OR

 

 

 

 

 

3

3

LR DDR3 ECC

1066

QR

 

 

 

 

 

1.5V UDIMM Population for the Motherboard w/5600 Processors Installed

DIMM

DIMMs

UDIMM (Unb. DIMM/

Speeds (in MHz)

Ranks per DIMM

Slots per

Populated

Unbuffered DIMM)

 

(any combination;

Channel

per Channel

 

 

SR=Single Rank,

 

 

 

 

DR=Dual Rank,

 

 

 

 

QR=Quad Rank)

3

1

Unb. DDR3 ECC/Non-ECC

800,1066,1333

SR or DR

 

 

 

 

 

3

2

Unb. DDR3 ECC/Non-ECC

800,1066, 1333

Mixing SR, DR

 

 

 

 

 

3

3

Not Available

Not Available

Not Available

 

 

 

 

 

Note 1: 1333 MHz for two DIMMs per channel is supported when Unbuf./ECC DIMMs are used.

Note 2: MIxing of 1.35V and 1.5V DIMMs is not recommended.

1.35V DIMMs

1.35V RDIMM Population for the Motherboard w/5600 Processors

 

DIMM

DIMMs

RDIMM (Reg. DIMM/

Speeds (in MHz)

Ranks per DIMM

 

 

Slots per

Populated

Registered DIMM)

 

(any combination;

 

Channel

per Channel

 

 

SR=Single Rank,

 

 

 

 

 

DR=Dual Rank,

 

 

 

 

 

QR=Quad Rank)

 

 

 

 

 

 

 

3

1

Reg. DDR3 ECC

800,1066,1333

SR or DR

3

1

Reg. DDR3 ECC

800 (Note 1)

QR

 

 

 

 

 

 

 

3-11

Image 37
Contents X8DTU-6F+ X8DTU-6TF+ X8DTU-6F+-LR X8DTU-6TF+-LR Page About This Motherboard Manual Organization PrefaceConventions Used in the Manual Headquarters Contacting SupermicroEurope Asia-PacificTable of Contents Vii Main Setup TroubleshootingInstalling the Passive CPU Heatsink Installing the CPUInstalling the I/O Shield Installing the Memory ModulesConnecting the Power Supply Installing the MotherboardInstalling External Peripherals Installing Internal PeripheralsOverview ChecklistMotherboard Image Motherboard Layout X8DTU-6F+X8DTU-6F+ X8DTU-6F+/X8DTU-6TF+/X8DTU-6TF+-LR Connectors Jumper Description Default SettingX8DTU-6F+/X8DTU-6TF+/X8DTU-6TF+-LR Jumpers Description State Status X8DTU-6F+/X8DTU-6TF+/X8DTU-6TF+-LR LED IndicatorsCPU Motherboard FeaturesChipset Bios System Block Diagram Overview PC Health Monitoring Special FeaturesPower Supply Acpi FeaturesSlow Blinking LED for Suspend-State Indicator Super I/O Overview of the Nuvoton WPCM450 ControllerInstallation Installing an LGA 1366 Processor Processor and Heatsink InstallationPage Installing a Passive CPU Heatsink Removing the Passive Heatsink Installing an Active Heatsink Removing the Active Heatsink Installing & Removing DIMMs Installing and Removing the Memory ModulesRemoving Memory Modules P1-DIMMs To Populate P1-DIMMs Branch Memory SupportCPU 1 To Populate P1-DIMMs CPU 2 To Populate P2-DIMMs Branch P2-DIMMs To Populate P2-DIMMs Branch35V Rdimm Population for the Motherboard w/5600 Processors 35V DIMMsTseg Possible System Memory Allocation & AvailabilityTools Needed Motherboard InstallationLocation of Mounting Holes Installing the Motherboard Back Panel Connectors/I/O Ports Control Panel Connectors/I/O PortsBack Panel I/O Port Locations and Definitions Keyboard Purple Mouse Green ATX PS/2 Keyboard and PS/2 Mouse PortsPS/2 Keyboard/Mouse Pin Definitions Backpanel USB Front Panel USB 4/5 Universal Serial Bus USBBackplane USB USB 0/1 Type a USBSerial Ports Video ConnectorCOM1 COM2 VGA Serial COM Ports Pin Definitions10Gb Tlan Ports and SFP+ Devices X8DTU-6TF+ Gigabit Ethernet PortsLAN Ports Pin Definition Rear UID Switch Unit Identifier SwitchesFP UID Switch Rear UID LED LEDFront Control Panel JF1 Header PinsPower LED Pin Definitions JF1 Power LEDFront Control Panel Pin Definitions NMI ButtonNIC1 LED Indicator HDD/FP UID SwitchFP UID Switch NIC1 Link LED NIC1 Activity LED HDD/UID Switch Pin Definitions JF1Overheat OH/Fan Fail/PWR Fail NIC2 LED IndicatorOH/Fan Fail/ PWR Fail/BlueUID LED Pin Definitions JF1 OH/Fan Fail/PWR Fail LED StatusReset Button Power Fail LEDPWR Fail LED Reset Button Reset Button Pin Definitions JF1Power Button Pin Definitions JF1 Power ButtonPWR Button Power Connectors Connecting CablesPin ATX PWR Reqd 8-pin Processor PWRChassis Intrusion Fan HeadersInternal Speaker Buzzer Internal SpeakerInternal Buzzer SP1 Pin Definition Ipmb Header Pin DefinitionsOverheat LED/Fan Fail DOM Power ConnectorOverheat LED Overheat LED Pin DefinitionsSgpio 1/2 Headers Power SMB I2C ConnectorSAS BBU Connector UIO Power ConnectorUIO Power Connector B. SAS Battery-Backup Unit Universal I/O Power Header Pin DefinitionsTrusted Platform Module Header TPM ConnectorTrusted Platform Module TPM Header Pin Definitions Glan and Tlan Enable Jumper SettingsGlan Ports 1/2 Enable Tlan Ports 1/2 Enable X8DTU- 6TF+ Explanation of JumpersClear Cmos Watch Dog Enable Watch Dog Enable/DisableWatch Dog Jumper Settings Cmos ClearI2C for PCI/PCI-E slots Jumper Settings VGA EnableVGA Enable I2C Bus to PCI-Exp. SlotsSAS Enable Jumper Settings SAS EnableRear View when facing the rear side of the chassis Onboard LED IndicatorsGlan 1/2 LEDs Ipmi Dedicated LAN LEDs10GbLAN LED X8DTU-6TF+ Onboard Power LEDOnboard PWR LED BMC Heartbeat LED Rear UID LEDBMC Heartbeat LED BMC Heartbeat LED LED StateSAS Error LED LED Status SAS Error LEDSAS Activity & SAS Heartbeat LEDs SAS Activity & SAS Heartbeat LEDs LED StatusSerial ATA Ports Serial ATA Sata and Serial Attached Scsi SAS ConnectionsSAS Ports Before Power On Troubleshooting ProceduresNo Power Losing the System’s Setup Configuration System Boot FailureNo Video When the System Becomes Unstable Memory ErrorsTechnical Support Procedures Question How do I update my BIOS? Frequently Asked QuestionsQuestion How do I handle the used battery? Returning Merchandise for ServiceQuestion Whats on the CD that came with my motherboard? Introduction Starting Bios Setup UtilityHow To Change the Configuration Data Main SetupStarting the Setup Utility SuperMicro X8DTU-6TF+ System Time/System DateProcessor System MemoryBoot Features Advanced Setup ConfigurationsProcessor and Clock Options Page MPS and Acpi Madt Ordering Intel AES-NI Available when supported by the OS and the CPUActive Processor Cores Intel Eist TechnologyQPI and IMC Configuration Advanced Chipset ControlQPI Quick Path Interconnect Links Speed Request Transaction IDQPI L0s and L1 Memory FrequencyNorth Bridge Chipset Configuration South Bridge Configuration IDE/SATA Configuration IDE Detect Timeout sec Ahci Codebase Available when RAID or Ahci is selectedLBA/Large Mode TypePIO Mode Select Options PIO ModeDMA Mode DMA Mode Select OptionsPCI/PnP Configuration Super IO Device Configuration Remote Access ConfigurationHardware Health Monitor CPU 1 Temperature/CPU 2 Temperature/System Temperature CPU Overheat AlarmCPU1 Temperature/CPU2 Temperature Fan Speed Control Modes Fan 1 ~ Fan 8 ReadingACPI Configuration Whea Support Intel Txtlt ConfigurationIntel TXT Initialization Trusted Computing Optional View BMC System Event Log IPMI ConfigurationIpmi Firmware Version Status of BMCSet LAN Configuration Subnet Mask When IP Address Source is set to StaticClear BMC System Event Log Clear BMC System Log now IP Address SourceEvent Log Configuration Memory ECC Error Log Security SettingsSupervisor Password User PasswordBoot Device Priority Boot ConfigurationChange User Password Password CheckExit Options Load Fail-Safe Defaults Load Optimal DefaultsSave Changes and Exit Discard Changes and ExitX8DTU-6F+/X8DTU-6TF+/X8DTU-6TF+-LR Motherboard User’s Manual Error Message Bios Error Beep CodesBeep Code Page Driver/Tool Installation Display Screen Installing Software ProgramsConfiguring Supero Doctor Supero Doctor III Interface Display Screen-II Remote Control