SUPER MICRO Computer X8DTU-6F+ Onboard LED Indicators, Glan 1/2 LEDs, Ipmi Dedicated LAN LEDs

Page 64

X8DTU-6F+/X8DTU-6TF+/X8DTU-6(T)F+-LR User's Manual

3-8 Onboard LED Indicators

GLAN 1/2 LEDs

Two LAN ports (LAN 1/LAN 2) are located on the I/O Backplane of the motherboard. Each Ethernet LAN port has two LEDs. The Green LED indicates activity, while the oth- er Link LED may be green, amber or off to indicate the speed of the connections. See the tables at right for more information.

IPMI Dedicated LAN LEDs

In addition to LAN 1/LAN 2, an IPMI Dedi- cated LAN is located on the I/O Backplane above the USB 0/1 ports . The amber LED on the right indicates activity, while the green LED on the left indicates the speed of the connection. See the table at right for more information.

LED2

 

LED7

B A

 

C

 

 

LAN2

LAN1

 

USB0/1

KB/MOUSE

UID

(10GbLAN2)

TLAN2

(10GbLAN1)

TLAN1

VGA

COM1

 

UIOP

 

 

 

 

 

 

 

 

IPMI_LAN

 

Activity LED

Link LED

Rear View (when facing the rear side of the chassis)

GLAN Activity LEDs (Left)

LED State

Color Status Definition

Green

Flashing

Active

 

 

 

GLAN Link LED (Right)

LED State

LED Color

 

Definition

Off

 

No Connection or 10 Mbps

 

Green

 

100 Mbps

 

Amber

 

1 Gbps

 

 

 

 

IPMI LAN (F models only)

Link LED

Activity LED

IPMI LAN Link LED (Left) &

Activity LED (Right)

 

Color/State

Definition

 

 

 

Link (Left)

Green: Solid

100 Mbps

 

 

 

Activity (Right)

Amber: Blinking

Active

 

 

 

A. LAN1 LEDs

B. LAN 2 LEDs

C. Dedicated LAN LEDs

J120

SAS0~3

SAS BBU

SAS

CTRL

LED6 LSI 2108 LED5LED4

JPS1

J2: PCI-E 2.0 X16

J1: PCI-E 2.0 X4 (in X16)

Intel 82599

JPL1

10 Gb LAN 1/2

 

CTRL

 

JPTLAN

 

CPU1

Intel 82576

LAN 1/2

CTRL

FAN8/CPU1

P1-DIMM1C

P1-DIMM1B

P1-DIMM1A

PHY

SP1

P1-DIMM2A P1-DIMM2B P1-DIMM2C

Battery

P1-DIMM3A P1-DIMM3B P1-DIMM3C

JI2C1

 

JWD1

X8DTU-6F+

LED3

 

 

 

 

JI2C2

JPG1

BMC

 

CTRL

 

TPM

JBT1

Intel

 

 

 

 

ICH 10R

BIOS

COM2

 

 

I-SATA0

 

USB6

I-SATA2

 

 

I-SATA1

 

JL1

I-SATA3

 

USB4/5

I-SATA4

 

JWF1 USB7

 

I-SATA5

 

 

T-SGPIO2 T-SGPIO1

FAN6

Intel

IOH 36D

P2-DIMM3A

P2-DIMM3C P2-DIMM3B

P2-DIMM2A

P2-DIMM2B

P2-DIMM1B P2-DIMM1A P2-DIMM2C

P2-DIMM1C

LED1

JOH1

FAN4 FAN5

IPMB

 

JF1

 

 

 

FAN3

 

CPU2

 

 

 

 

 

 

JPW1

FAN2

FAN7/CPU2

JPI2C1

FAN1

JPW3 JPW2

3-38

Image 64
Contents X8DTU-6F+ X8DTU-6TF+ X8DTU-6F+-LR X8DTU-6TF+-LR Page Preface About This Motherboard Manual OrganizationConventions Used in the Manual Contacting Supermicro HeadquartersEurope Asia-PacificTable of Contents Vii Troubleshooting Main SetupInstalling the CPU Installing the Passive CPU HeatsinkInstalling the Memory Modules Installing the I/O ShieldInstalling the Motherboard Connecting the Power SupplyInstalling Internal Peripherals Installing External PeripheralsChecklist OverviewMotherboard Image X8DTU-6F+ Motherboard LayoutX8DTU-6F+ X8DTU-6F+/X8DTU-6TF+/X8DTU-6TF+-LR Connectors Jumper Description Default SettingX8DTU-6F+/X8DTU-6TF+/X8DTU-6TF+-LR Jumpers X8DTU-6F+/X8DTU-6TF+/X8DTU-6TF+-LR LED Indicators Description State StatusMotherboard Features CPUChipset Bios System Block Diagram Overview Special Features PC Health MonitoringPower Supply Acpi FeaturesSlow Blinking LED for Suspend-State Indicator Overview of the Nuvoton WPCM450 Controller Super I/OInstallation Processor and Heatsink Installation Installing an LGA 1366 ProcessorPage Installing a Passive CPU Heatsink Removing the Passive Heatsink Installing an Active Heatsink Removing the Active Heatsink Installing & Removing DIMMs Installing and Removing the Memory ModulesRemoving Memory Modules Memory Support P1-DIMMs To Populate P1-DIMMs BranchP2-DIMMs To Populate P2-DIMMs Branch CPU 1 To Populate P1-DIMMs CPU 2 To Populate P2-DIMMs Branch35V DIMMs 35V Rdimm Population for the Motherboard w/5600 ProcessorsPossible System Memory Allocation & Availability TsegTools Needed Motherboard InstallationLocation of Mounting Holes Installing the Motherboard Back Panel Connectors/I/O Ports Control Panel Connectors/I/O PortsBack Panel I/O Port Locations and Definitions Keyboard Purple Mouse Green ATX PS/2 Keyboard and PS/2 Mouse PortsPS/2 Keyboard/Mouse Pin Definitions Universal Serial Bus USB Backpanel USB Front Panel USB 4/5Backplane USB USB 0/1 Type a USBVideo Connector Serial PortsCOM1 COM2 VGA Serial COM Ports Pin Definitions10Gb Tlan Ports and SFP+ Devices X8DTU-6TF+ Gigabit Ethernet PortsLAN Ports Pin Definition Unit Identifier Switches Rear UID SwitchFP UID Switch Rear UID LED LEDJF1 Header Pins Front Control PanelPower LED Power LED Pin Definitions JF1Front Control Panel Pin Definitions NMI ButtonHDD/FP UID Switch NIC1 LED IndicatorFP UID Switch NIC1 Link LED NIC1 Activity LED HDD/UID Switch Pin Definitions JF1NIC2 LED Indicator Overheat OH/Fan Fail/PWR FailOH/Fan Fail/ PWR Fail/BlueUID LED Pin Definitions JF1 OH/Fan Fail/PWR Fail LED StatusPower Fail LED Reset ButtonPWR Fail LED Reset Button Reset Button Pin Definitions JF1Power Button Pin Definitions JF1 Power ButtonPWR Button Connecting Cables Power ConnectorsPin ATX PWR Reqd 8-pin Processor PWRFan Headers Chassis IntrusionInternal Speaker Internal Speaker BuzzerInternal Buzzer SP1 Pin Definition Ipmb Header Pin DefinitionsDOM Power Connector Overheat LED/Fan FailOverheat LED Overheat LED Pin DefinitionsPower SMB I2C Connector Sgpio 1/2 HeadersUIO Power Connector SAS BBU ConnectorUIO Power Connector B. SAS Battery-Backup Unit Universal I/O Power Header Pin DefinitionsTrusted Platform Module Header TPM ConnectorTrusted Platform Module TPM Header Pin Definitions Jumper Settings Glan and Tlan EnableGlan Ports 1/2 Enable Tlan Ports 1/2 Enable X8DTU- 6TF+ Explanation of Jumpers Watch Dog Enable/Disable Clear Cmos Watch Dog Enable Watch Dog Jumper Settings Cmos ClearVGA Enable I2C for PCI/PCI-E slots Jumper SettingsVGA Enable I2C Bus to PCI-Exp. SlotsSAS Enable SAS Enable Jumper SettingsOnboard LED Indicators Rear View when facing the rear side of the chassisGlan 1/2 LEDs Ipmi Dedicated LAN LEDs10GbLAN LED X8DTU-6TF+ Onboard Power LEDOnboard PWR LED Rear UID LED BMC Heartbeat LEDBMC Heartbeat LED BMC Heartbeat LED LED StateSAS Error LED SAS Error LED LED StatusSAS Activity & SAS Heartbeat LEDs SAS Activity & SAS Heartbeat LEDs LED StatusSerial ATA Ports Serial ATA Sata and Serial Attached Scsi SAS ConnectionsSAS Ports Before Power On Troubleshooting ProceduresNo Power Losing the System’s Setup Configuration System Boot FailureNo Video Memory Errors When the System Becomes UnstableTechnical Support Procedures Frequently Asked Questions Question How do I update my BIOS?Question How do I handle the used battery? Returning Merchandise for ServiceQuestion Whats on the CD that came with my motherboard? Starting Bios Setup Utility IntroductionHow To Change the Configuration Data Main SetupStarting the Setup Utility System Time/System Date SuperMicro X8DTU-6TF+Processor System MemoryAdvanced Setup Configurations Boot FeaturesProcessor and Clock Options Page Intel AES-NI Available when supported by the OS and the CPU MPS and Acpi Madt OrderingActive Processor Cores Intel Eist TechnologyAdvanced Chipset Control QPI and IMC ConfigurationRequest Transaction ID QPI Quick Path Interconnect Links SpeedQPI L0s and L1 Memory FrequencyNorth Bridge Chipset Configuration South Bridge Configuration IDE/SATA Configuration Ahci Codebase Available when RAID or Ahci is selected IDE Detect Timeout secLBA/Large Mode TypePIO Mode PIO Mode Select OptionsDMA Mode DMA Mode Select OptionsPCI/PnP Configuration Remote Access Configuration Super IO Device ConfigurationHardware Health Monitor CPU 1 Temperature/CPU 2 Temperature/System Temperature CPU Overheat AlarmCPU1 Temperature/CPU2 Temperature Fan 1 ~ Fan 8 Reading Fan Speed Control ModesACPI Configuration Whea Support Intel Txtlt ConfigurationIntel TXT Initialization Trusted Computing Optional IPMI Configuration View BMC System Event LogIpmi Firmware Version Status of BMCSubnet Mask When IP Address Source is set to Static Set LAN ConfigurationClear BMC System Event Log Clear BMC System Log now IP Address SourceEvent Log Configuration Security Settings Memory ECC Error LogSupervisor Password User PasswordBoot Configuration Boot Device PriorityChange User Password Password CheckExit Options Load Optimal Defaults Load Fail-Safe DefaultsSave Changes and Exit Discard Changes and ExitX8DTU-6F+/X8DTU-6TF+/X8DTU-6TF+-LR Motherboard User’s Manual Error Message Bios Error Beep CodesBeep Code Page Installing Software Programs Driver/Tool Installation Display ScreenConfiguring Supero Doctor Supero Doctor III Interface Display Screen-II Remote Control