SUPER MICRO Computer AS 1020C-3 Connecting the Control Panel, Front Control Panel Header Pins JF1

Page 40

AS1020C-3 User's Manual

Connecting the Control Panel

JF1 contains header pins for various front control panel connectors. See Figure 5-2 for the pin locations of the various front control panel buttons and LED indica- tors and refer to section 5-9 for details. Note that even and odd numbered pins are on opposite sides of each header.

All JF1 wires have been bundled into single keyed ribbon cable to simplify their connection. The red wire in the ribbon cable plugs into pin 1 of JF1. Connect the other end of the cable to the Control Panel printed circuit board, located just behind the system status LEDs in the chassis.

See the Connector Defi nitions section in this chapter for details and pin descrip- tions of JF1.

Figure 5-2. Front Control Panel Header Pins (JF1)

20

19

Ground

NMI

x (key)

x (key)

Power LED

Vcc

HDD LED

Vcc

NIC1

Vcc

NIC2

Vcc

OH/Fan Fail LED

Vcc

Power Fail LED

Vcc

Ground

Reset

Ground

Power

2

1

5-6

Image 40
Contents AS 1020C-3 Manual Revision Release Date October 13 About This Manual PrefaceManual Organization System Safety Advanced Serverboard SetupAdvanced Chassis Setup BiosPreface Table of Contents System Safety Advanced Serverboard SetupAdvanced Chassis Setup PssmbusBios AppendicesPage Chapter Introduction OverviewServerboard Features ProcessorsMemory SAS Serial Attached ScsiATI Graphics Controller Other FeaturesOnboard Controllers/Ports Server Chassis Features System PowerSerial Attached Scsi SAS Subsystem Control PanelNVidia nForce Pro 2200/AMD-8132 Chipset System Block Diagram Cooling SystemContacting Supermicro HeadquartersEurope Asia-PacificPreparing for Setup Chapter Server InstallationUnpacking the System Rack Precautions Choosing a Setup LocationServer Precautions Rack Mounting Considerations Installing the Rack Rails Installing the System into a RackIdentifying the Sections of the Rails Installing the Chassis Rails Identifying the Sections of the RailsInstalling the Server into the Rack Installing the Server into a RackInstalling the Server into a Telco Rack Installing the Server into a Telco RackChecking the Serverboard Setup Checking the Drive Bay Setup Accessing the drive baysCD-ROM and floppy disk drives Check the SAS disk drivesSupplying power to the system Check the airflowChapter System Interface Control Panel ButtonsControl Panel LEDs SAS Drive Carrier LEDs Page Chapter System Safety Electrical Safety PrecautionsGeneral Safety Precautions ESD Precautions Operating Precautions Installing the Onboard BatteryChapter Advanced Serverboard Setup PrecautionsHandling the Serverboard UnpackingMounting the Serverboard into a Chassis Processor and Heatsink InstallationCPU Backplates Installing the Processor Is not recommendedInstalling the Heatsinks Installing HeatsinksConnecting Data Cables Connecting CablesConnecting Power Cables Connecting the Control Panel Front Control Panel Header Pins JF1I/O Ports Installing MemorySupport Optimizing memory performance Maximum memory two CPUsAdding PCI Cards PCI card installationPCI slots Serverboard Details H8DCR-3 Serverboard LayoutJumpers Description Default Setting Connectors DescriptionOnboard Indicators Description H8DCR-3 Quick ReferenceConnector Definitions ATX Power ConnectorProcessor Power Connector Auxiliary Power ConnectorPower LED Overheat/Fan Fail LEDReset Button Power ButtonLAN1/2 Ethernet Ports Universal Serial Bus Ports USB0/1Extra USB Headers Serial PortsFan Headers Chassis IntrusionATX PS/2 Keyboard and PS/2 Mouse Ports Power LED/SpeakerOverheat LED Alarm Reset Header Wake-On-LANWake-On-Ring SMBus HeaderPower Fail Connector Compact Flash Power ConnectorI2C for SAS Connector JSLED1 HeaderExplanation Jumpers Jumper SettingsCmos Clear 3rd Power Supply Fail Signal Enable/Disable I2C to PCI Enable/DisableVGA Enable/Disable Compact Flash Master/SlaveOnboard Speaker Enable/ Disable Watch Dog Enable/DisableSAS Controller Enable Disable LAN1/2 Enable/Disable PCI-X Slot Frequency SelectOnboard Indicators LAN1/LAN2 LEDs+3.3V Standby LED SAS Activity LEDsFloppy Connector Floppy, IDE and SAS ConnectionsIDE Connectors SAS PortsSerial Attached Scsi SAS Enabling SAS RAIDEnabling SAS RAID SAS Controller Utility Creating a RAID ArrayArray Configuration Utility Screen Additional Functions Selecting Drives for the ArrayInstalling Drivers 10. Driver/Tool Installation Display ScreenStatic-Sensitive Devices Chapter Advanced Chassis SetupTools Required Control Panel Chassis Front and Rear ViewsInstalling a new fan System FansSystem Fan Failure Replacing System Cooling FansDrive Bay Installation/Removal Removing the Front BezelAccessing the Drive Bays Removing the Front BezelSerial Attached Scsi SAS Drive Installation Mounting a SAS drive in a drive carrierInstalling/removing hot-swap SAS drives SAS BackplaneCD-ROM and Floppy Drive Installation Power Supply Power Supply FailureRemoving/Replacing the Power Supply Removing the power supplyRemoving/Replacing the Power Supply Chapter Starting the Setup UtilityIntroduction Advanced Settings Menu Main MenuCPU Configuration IDE ConfigurationLBA/Large Mode Primary/Secondary IDE Master/SlaveType Block Multi-Sector TransferDMA Mode First Boot Device FromA.R.T Bit Data TransferConfiguration nVidia RAID ROM PCI/PnP MenuFloppy Configuration Advanced Chipset Control NorthBridge ConfigurationUser Config Mode ECC Configuration Dram ECC EnableBank Interleaving Burst LengthSouthBridge Configuration Device Configuration Hyper Transport Configuration DMI Event Logging AMD PowerNow ConfigurationConsole Redirection System Health Monitor Ipmi 1.5 ConfigurationAlert Startup Delay Startup DelayCbmc Watch Dog Timer Action Set LAN Configuration IP AddressUSB 2.0 Controller Mode Bios Ehci Hand-OffUSB Configuration USB Controller SupportBoot Menu Boot Settings ConfigurationBoot Device Priority OS InstallationSecurity Menu Removeable DrivesExit Menu Page Amibios Error Beep Codes Appendix a Bios Error Beep CodesBeep Code Error Message Description AS1020C-3 User’s Manual Appendix B Bios Post Checkpoint Codes Uncompressed Initialization CodesBootblock Recovery Codes Uncompressed Initialization Codes AS1020C-3 User’s Manual Appendix B Bios Post Checkpoint Codes AS1020C-3 User’s Manual A9h Aah Abh B0h B1h 00h AS1020C-3 User’s Manual Appendix C System Specifications Weight Power SupplyServerboard ChassisRegulatory Compliance