SUPER MICRO Computer AS 1020C-3 PCI/PnP Menu, Configuration nVidia RAID ROM, Floppy Configuration

Page 79

Chapter 7: BIOS

Configuration nVidia RAID ROM

RAID Option ROM

This setting is used to Enable or Disable the nVidia ROM. If enabled, the set- ting below will appear.

Master SATA as RAID

This setting is used to set the third master as a RAID drive. The options are Enabled or Disabled.

Floppy Configuration

Floppy A

Move the cursor to these fi elds via up and down <arrow> keys to select the fl oppy type. The options are Disabled, 360 KB 5 1/4", 1.2 MB 5 1/4", 720 KB 3½", 1.44 MB 3½”, and 2.88 MB 3½".

Floppy B

Move the cursor to these fi elds via up and down <arrow> keys to select the fl oppy type. The options are Disabled, 360 KB 5 1/4", 1.2 MB 5 1/4", 720 KB 3½", 1.44 MB 3½”, and 2.88 MB 3½".

Onboard Floppy Controller

Use this setting to Enable or Disable the onboard fl oppy controller.

PCI/PnP Menu

Clear NVRAM

Select Yes to clear NVRAM during boot-up. The options are Yes and No.

Plug & Play OS

Select Yes to allow the OS to confi gure Plug & Play devices. (This is not required for system boot if your system has an OS that supports Plug & Play.) Select No to allow AMIBIOS to confi gure all devices in the system.

PCI Latency Timer

This option sets the latency of all PCI devices on the PCI bus. Select a value to set the PCI latency in PCI clock cycles. Options are 32, 64, 96, 128, 160, 192, 224 and 248.

7-5

Image 79
Contents AS 1020C-3 Manual Revision Release Date October 13 About This Manual PrefaceManual Organization Bios System SafetyAdvanced Serverboard Setup Advanced Chassis SetupPreface Table of Contents Advanced Serverboard Setup System SafetyPssmbus Advanced Chassis SetupAppendices BiosPage Overview Chapter IntroductionSAS Serial Attached Scsi Serverboard FeaturesProcessors MemoryATI Graphics Controller Other FeaturesOnboard Controllers/Ports Control Panel Server Chassis FeaturesSystem Power Serial Attached Scsi SAS SubsystemCooling System NVidia nForce Pro 2200/AMD-8132 Chipset System Block DiagramAsia-Pacific Contacting SupermicroHeadquarters EuropePreparing for Setup Chapter Server InstallationUnpacking the System Rack Precautions Choosing a Setup LocationServer Precautions Rack Mounting Considerations Installing the Rack Rails Installing the System into a RackIdentifying the Sections of the Rails Identifying the Sections of the Rails Installing the Chassis RailsInstalling the Server into a Rack Installing the Server into the RackInstalling the Server into a Telco Rack Installing the Server into a Telco RackChecking the Serverboard Setup Check the SAS disk drives Checking the Drive Bay SetupAccessing the drive bays CD-ROM and floppy disk drivesCheck the airflow Supplying power to the systemControl Panel Buttons Chapter System InterfaceControl Panel LEDs SAS Drive Carrier LEDs Page Electrical Safety Precautions Chapter System SafetyGeneral Safety Precautions ESD Precautions Installing the Onboard Battery Operating PrecautionsUnpacking Chapter Advanced Serverboard SetupPrecautions Handling the ServerboardMounting the Serverboard into a Chassis Processor and Heatsink InstallationCPU Backplates Is not recommended Installing the ProcessorInstalling Heatsinks Installing the HeatsinksConnecting Data Cables Connecting CablesConnecting Power Cables Front Control Panel Header Pins JF1 Connecting the Control PanelI/O Ports Installing MemorySupport Maximum memory two CPUs Optimizing memory performanceAdding PCI Cards PCI card installationPCI slots H8DCR-3 Serverboard Layout Serverboard DetailsH8DCR-3 Quick Reference Jumpers Description Default SettingConnectors Description Onboard Indicators DescriptionAuxiliary Power Connector Connector DefinitionsATX Power Connector Processor Power ConnectorOverheat/Fan Fail LED Power LEDUniversal Serial Bus Ports USB0/1 Reset ButtonPower Button LAN1/2 Ethernet PortsChassis Intrusion Extra USB HeadersSerial Ports Fan HeadersATX PS/2 Keyboard and PS/2 Mouse Ports Power LED/SpeakerOverheat LED SMBus Header Alarm Reset HeaderWake-On-LAN Wake-On-RingJSLED1 Header Power Fail ConnectorCompact Flash Power Connector I2C for SAS ConnectorExplanation Jumpers Jumper SettingsCmos Clear Compact Flash Master/Slave 3rd Power Supply Fail Signal Enable/DisableI2C to PCI Enable/Disable VGA Enable/DisableOnboard Speaker Enable/ Disable Watch Dog Enable/DisableSAS Controller Enable Disable PCI-X Slot Frequency Select LAN1/2 Enable/DisableSAS Activity LEDs Onboard IndicatorsLAN1/LAN2 LEDs +3.3V Standby LEDFloppy, IDE and SAS Connections Floppy ConnectorSAS Ports IDE ConnectorsSerial Attached Scsi SAS Enabling SAS RAIDEnabling SAS RAID Creating a RAID Array SAS Controller UtilityArray Configuration Utility Screen Selecting Drives for the Array Additional Functions10. Driver/Tool Installation Display Screen Installing DriversStatic-Sensitive Devices Chapter Advanced Chassis SetupTools Required Chassis Front and Rear Views Control PanelReplacing System Cooling Fans Installing a new fanSystem Fans System Fan FailureRemoving the Front Bezel Drive Bay Installation/RemovalRemoving the Front Bezel Accessing the Drive BaysMounting a SAS drive in a drive carrier Serial Attached Scsi SAS Drive InstallationSAS Backplane Installing/removing hot-swap SAS drivesCD-ROM and Floppy Drive Installation Removing the power supply Power SupplyPower Supply Failure Removing/Replacing the Power SupplyRemoving/Replacing the Power Supply Chapter Starting the Setup UtilityIntroduction IDE Configuration Advanced Settings MenuMain Menu CPU ConfigurationBlock Multi-Sector Transfer LBA/Large ModePrimary/Secondary IDE Master/Slave TypeBit Data Transfer DMA ModeFirst Boot Device From A.R.TConfiguration nVidia RAID ROM PCI/PnP MenuFloppy Configuration NorthBridge Configuration Advanced Chipset ControlBurst Length User Config ModeECC Configuration Dram ECC Enable Bank InterleavingSouthBridge Configuration Device Configuration Hyper Transport Configuration DMI Event Logging AMD PowerNow ConfigurationConsole Redirection Ipmi 1.5 Configuration System Health MonitorSet LAN Configuration IP Address Alert Startup DelayStartup Delay Cbmc Watch Dog Timer ActionUSB Controller Support USB 2.0 Controller ModeBios Ehci Hand-Off USB ConfigurationBoot Settings Configuration Boot MenuRemoveable Drives Boot Device PriorityOS Installation Security MenuExit Menu Page Amibios Error Beep Codes Appendix a Bios Error Beep CodesBeep Code Error Message Description AS1020C-3 User’s Manual Uncompressed Initialization Codes Appendix B Bios Post Checkpoint CodesBootblock Recovery Codes Uncompressed Initialization Codes AS1020C-3 User’s Manual Appendix B Bios Post Checkpoint Codes AS1020C-3 User’s Manual A9h Aah Abh B0h B1h 00h AS1020C-3 User’s Manual Appendix C System Specifications Chassis WeightPower Supply ServerboardRegulatory Compliance