SUPER MICRO Computer AS 1020C-3 user manual Appendix C System Specifications

Page 103

Appendix C: System Specifi cations

Appendix C

System Specifications

Processors

Dual AMD Opteron200 Series 64-bit processors in to 940-pin ZIF sockets

Chipset

nVidia nForce Pro 2200/AMD-8132

BIOS

8 Mb AMIBIOS® LPC Flash ROM

Memory Capacity

Eight 184-pin DIMM sockets supporting up to 32 GB of registered ECC DDR333/266 or up to 16 GB of registered ECC DDR400 SDRAM

Note: Both interleaved and non-interleaved memory supported. Memory capacity is halved

when using a single processor. See the memory section in Chapter 5 for details.

SAS Controller

Adaptec AIC-9410W for 4-port SAS (RAID 0, 1, 0+1 and JBOD supported)

SAS Backplane

One (1) CSE-SAS-813TQ 1U SAS backplane

SAS Drive Bays

Four (4) drive bays to house four (4) standard SAS drives

Peripheral Drive Bays

One (1) slim 3.5" fl oppy drive

One (1) slim CD-ROM drive

Expansion Slots (provided with included riser cards)

One (1) full height, half length 133 MHz PCI-X or PCI-Express x8, and One (1) low-profi le 100 MHz PCI-X slot or PCI-Express x8 add-on card.

C-1

Image 103
Contents AS 1020C-3 Manual Revision Release Date October 13 About This Manual PrefaceManual Organization Bios System SafetyAdvanced Serverboard Setup Advanced Chassis SetupPreface Table of Contents Advanced Serverboard Setup System SafetyPssmbus Advanced Chassis SetupAppendices BiosPage Overview Chapter IntroductionSAS Serial Attached Scsi Serverboard FeaturesProcessors MemoryATI Graphics Controller Other FeaturesOnboard Controllers/Ports Control Panel Server Chassis FeaturesSystem Power Serial Attached Scsi SAS SubsystemCooling System NVidia nForce Pro 2200/AMD-8132 Chipset System Block DiagramAsia-Pacific Contacting SupermicroHeadquarters EuropePreparing for Setup Chapter Server InstallationUnpacking the System Rack Precautions Choosing a Setup LocationServer Precautions Rack Mounting Considerations Installing the Rack Rails Installing the System into a RackIdentifying the Sections of the Rails Identifying the Sections of the Rails Installing the Chassis RailsInstalling the Server into a Rack Installing the Server into the RackInstalling the Server into a Telco Rack Installing the Server into a Telco RackChecking the Serverboard Setup Check the SAS disk drives Checking the Drive Bay SetupAccessing the drive bays CD-ROM and floppy disk drivesCheck the airflow Supplying power to the systemControl Panel Buttons Chapter System InterfaceControl Panel LEDs SAS Drive Carrier LEDs Page Electrical Safety Precautions Chapter System SafetyGeneral Safety Precautions ESD Precautions Installing the Onboard Battery Operating PrecautionsUnpacking Chapter Advanced Serverboard SetupPrecautions Handling the ServerboardMounting the Serverboard into a Chassis Processor and Heatsink InstallationCPU Backplates Is not recommended Installing the ProcessorInstalling Heatsinks Installing the HeatsinksConnecting Data Cables Connecting CablesConnecting Power Cables Front Control Panel Header Pins JF1 Connecting the Control PanelI/O Ports Installing MemorySupport Maximum memory two CPUs Optimizing memory performanceAdding PCI Cards PCI card installationPCI slots H8DCR-3 Serverboard Layout Serverboard DetailsH8DCR-3 Quick Reference Jumpers Description Default SettingConnectors Description Onboard Indicators DescriptionAuxiliary Power Connector Connector DefinitionsATX Power Connector Processor Power ConnectorOverheat/Fan Fail LED Power LEDUniversal Serial Bus Ports USB0/1 Reset ButtonPower Button LAN1/2 Ethernet PortsChassis Intrusion Extra USB HeadersSerial Ports Fan HeadersATX PS/2 Keyboard and PS/2 Mouse Ports Power LED/SpeakerOverheat LED SMBus Header Alarm Reset HeaderWake-On-LAN Wake-On-RingJSLED1 Header Power Fail ConnectorCompact Flash Power Connector I2C for SAS ConnectorExplanation Jumpers Jumper SettingsCmos Clear Compact Flash Master/Slave 3rd Power Supply Fail Signal Enable/DisableI2C to PCI Enable/Disable VGA Enable/DisableOnboard Speaker Enable/ Disable Watch Dog Enable/DisableSAS Controller Enable Disable PCI-X Slot Frequency Select LAN1/2 Enable/DisableSAS Activity LEDs Onboard IndicatorsLAN1/LAN2 LEDs +3.3V Standby LEDFloppy, IDE and SAS Connections Floppy ConnectorSAS Ports IDE ConnectorsSerial Attached Scsi SAS Enabling SAS RAIDEnabling SAS RAID Creating a RAID Array SAS Controller UtilityArray Configuration Utility Screen Selecting Drives for the Array Additional Functions10. Driver/Tool Installation Display Screen Installing DriversStatic-Sensitive Devices Chapter Advanced Chassis SetupTools Required Chassis Front and Rear Views Control PanelReplacing System Cooling Fans Installing a new fanSystem Fans System Fan FailureRemoving the Front Bezel Drive Bay Installation/RemovalRemoving the Front Bezel Accessing the Drive BaysMounting a SAS drive in a drive carrier Serial Attached Scsi SAS Drive InstallationSAS Backplane Installing/removing hot-swap SAS drivesCD-ROM and Floppy Drive Installation Removing the power supply Power SupplyPower Supply Failure Removing/Replacing the Power SupplyRemoving/Replacing the Power Supply Chapter Starting the Setup UtilityIntroduction IDE Configuration Advanced Settings MenuMain Menu CPU ConfigurationBlock Multi-Sector Transfer LBA/Large ModePrimary/Secondary IDE Master/Slave TypeBit Data Transfer DMA ModeFirst Boot Device From A.R.TConfiguration nVidia RAID ROM PCI/PnP MenuFloppy Configuration NorthBridge Configuration Advanced Chipset ControlBurst Length User Config ModeECC Configuration Dram ECC Enable Bank InterleavingSouthBridge Configuration Device Configuration Hyper Transport Configuration DMI Event Logging AMD PowerNow ConfigurationConsole Redirection Ipmi 1.5 Configuration System Health MonitorSet LAN Configuration IP Address Alert Startup DelayStartup Delay Cbmc Watch Dog Timer ActionUSB Controller Support USB 2.0 Controller ModeBios Ehci Hand-Off USB ConfigurationBoot Settings Configuration Boot MenuRemoveable Drives Boot Device PriorityOS Installation Security MenuExit Menu Page Amibios Error Beep Codes Appendix a Bios Error Beep CodesBeep Code Error Message Description AS1020C-3 User’s Manual Uncompressed Initialization Codes Appendix B Bios Post Checkpoint CodesBootblock Recovery Codes Uncompressed Initialization Codes AS1020C-3 User’s Manual Appendix B Bios Post Checkpoint Codes AS1020C-3 User’s Manual A9h Aah Abh B0h B1h 00h AS1020C-3 User’s Manual Appendix C System Specifications Chassis WeightPower Supply ServerboardRegulatory Compliance