SUPER MICRO Computer AS 1020C-3 user manual AS1020C-3 User’s Manual

Page 100

AS1020C-3 User’s Manual

Checkpoint

86h

87h

88h

89h

8Ch

8Dh

8Fh

91h

95h

96h

97h

98h

99h

9Ah

9Bh

9Ch

9Dh

9Eh

A2h

A3h

A4h

A5h

A7h

A8h

Code Description

The password was checked. Performing any required programming before WIN- BIOS Setup next.

The programming before WINBIOS Setup has completed. Uncompressing the WINBIOS Setup code and executing the AMIBIOS Setup or WINBIOS Setup utility next.

Returned from WINBIOS Setup and cleared the screen. Performing any necessary programming after WINBIOS Setup next.

The programming after WINBIOS Setup has completed. Displaying the power on screen message next.

Programming the WINBIOS Setup options next.

The WINBIOS Setup options are programmed. Resetting the hard disk controller next.

The hard disk controller has been reset. Confi guring the fl oppy drive controller next.

The fl oppy drive controller has been confi gured. Confi guring the hard disk drive controller next.

Initializing the bus option ROMs from C800 next. See the last page of this chapter for additional information.

Initializing before passing control to the adaptor ROM at C800.

Initialization before the C800 adaptor ROM gains control has completed. The adap- tor ROM check is next.

The adaptor ROM had control and has now returned control to BIOS POST. Perform- ing any required processing after the option ROM returned control.

Any initialization required after the option ROM test has completed. Confi guring the timer data area and printer base address next.

Set the timer and printer base addresses. Setting the RS-232 base address next.

Returned after setting the RS-232 base address. Performing any required initializa- tion before the Coprocessor test next.

Required initialization before the Coprocessor test is over. Initializing the Coproces- sor next.

Coprocessor initialized. Performing any required initialization after the Coproces- sor test next.

Initialization after the Coprocessor test is complete. Checking the extended keyboard, keyboard ID, and Num Lock key next. Issuing the keyboard ID command next.

Displaying any soft errors next.

The soft error display has completed. Setting the keyboard typematic rate next.

The keyboard typematic rate is set. Programming the memory wait states next.

Memory wait state programming is over. Clearing the screen and enabling parity and the NMI next.

NMI and parity enabled. Performing any initialization required before passing control to the adaptor ROM at E000 next.

Initialization before passing control to the adaptor ROM at E000h completed. Passing control to the adaptor ROM at E000h next.

B-6

Image 100
Contents AS 1020C-3 Manual Revision Release Date October 13 About This Manual PrefaceManual Organization System Safety Advanced Serverboard SetupAdvanced Chassis Setup BiosPreface Table of Contents System Safety Advanced Serverboard SetupAdvanced Chassis Setup PssmbusBios AppendicesPage Chapter Introduction OverviewServerboard Features ProcessorsMemory SAS Serial Attached ScsiATI Graphics Controller Other FeaturesOnboard Controllers/Ports Server Chassis Features System PowerSerial Attached Scsi SAS Subsystem Control PanelNVidia nForce Pro 2200/AMD-8132 Chipset System Block Diagram Cooling SystemContacting Supermicro HeadquartersEurope Asia-PacificPreparing for Setup Chapter Server InstallationUnpacking the System Rack Precautions Choosing a Setup LocationServer Precautions Rack Mounting Considerations Installing the Rack Rails Installing the System into a RackIdentifying the Sections of the Rails Installing the Chassis Rails Identifying the Sections of the RailsInstalling the Server into the Rack Installing the Server into a RackInstalling the Server into a Telco Rack Installing the Server into a Telco RackChecking the Serverboard Setup Checking the Drive Bay Setup Accessing the drive baysCD-ROM and floppy disk drives Check the SAS disk drivesSupplying power to the system Check the airflowChapter System Interface Control Panel ButtonsControl Panel LEDs SAS Drive Carrier LEDs Page Chapter System Safety Electrical Safety PrecautionsGeneral Safety Precautions ESD Precautions Operating Precautions Installing the Onboard BatteryChapter Advanced Serverboard Setup PrecautionsHandling the Serverboard UnpackingMounting the Serverboard into a Chassis Processor and Heatsink InstallationCPU Backplates Installing the Processor Is not recommendedInstalling the Heatsinks Installing HeatsinksConnecting Data Cables Connecting CablesConnecting Power Cables Connecting the Control Panel Front Control Panel Header Pins JF1I/O Ports Installing MemorySupport Optimizing memory performance Maximum memory two CPUsAdding PCI Cards PCI card installationPCI slots Serverboard Details H8DCR-3 Serverboard LayoutJumpers Description Default Setting Connectors DescriptionOnboard Indicators Description H8DCR-3 Quick ReferenceConnector Definitions ATX Power ConnectorProcessor Power Connector Auxiliary Power ConnectorPower LED Overheat/Fan Fail LEDReset Button Power ButtonLAN1/2 Ethernet Ports Universal Serial Bus Ports USB0/1Extra USB Headers Serial PortsFan Headers Chassis IntrusionATX PS/2 Keyboard and PS/2 Mouse Ports Power LED/SpeakerOverheat LED Alarm Reset Header Wake-On-LANWake-On-Ring SMBus HeaderPower Fail Connector Compact Flash Power ConnectorI2C for SAS Connector JSLED1 HeaderExplanation Jumpers Jumper SettingsCmos Clear 3rd Power Supply Fail Signal Enable/Disable I2C to PCI Enable/DisableVGA Enable/Disable Compact Flash Master/SlaveOnboard Speaker Enable/ Disable Watch Dog Enable/DisableSAS Controller Enable Disable LAN1/2 Enable/Disable PCI-X Slot Frequency SelectOnboard Indicators LAN1/LAN2 LEDs+3.3V Standby LED SAS Activity LEDsFloppy Connector Floppy, IDE and SAS ConnectionsIDE Connectors SAS PortsSerial Attached Scsi SAS Enabling SAS RAIDEnabling SAS RAID SAS Controller Utility Creating a RAID ArrayArray Configuration Utility Screen Additional Functions Selecting Drives for the ArrayInstalling Drivers 10. Driver/Tool Installation Display ScreenStatic-Sensitive Devices Chapter Advanced Chassis SetupTools Required Control Panel Chassis Front and Rear ViewsInstalling a new fan System FansSystem Fan Failure Replacing System Cooling FansDrive Bay Installation/Removal Removing the Front BezelAccessing the Drive Bays Removing the Front BezelSerial Attached Scsi SAS Drive Installation Mounting a SAS drive in a drive carrierInstalling/removing hot-swap SAS drives SAS BackplaneCD-ROM and Floppy Drive Installation Power Supply Power Supply FailureRemoving/Replacing the Power Supply Removing the power supplyRemoving/Replacing the Power Supply Chapter Starting the Setup UtilityIntroduction Advanced Settings Menu Main MenuCPU Configuration IDE ConfigurationLBA/Large Mode Primary/Secondary IDE Master/SlaveType Block Multi-Sector TransferDMA Mode First Boot Device FromA.R.T Bit Data TransferConfiguration nVidia RAID ROM PCI/PnP MenuFloppy Configuration Advanced Chipset Control NorthBridge ConfigurationUser Config Mode ECC Configuration Dram ECC EnableBank Interleaving Burst LengthSouthBridge Configuration Device Configuration Hyper Transport Configuration DMI Event Logging AMD PowerNow ConfigurationConsole Redirection System Health Monitor Ipmi 1.5 ConfigurationAlert Startup Delay Startup DelayCbmc Watch Dog Timer Action Set LAN Configuration IP AddressUSB 2.0 Controller Mode Bios Ehci Hand-OffUSB Configuration USB Controller SupportBoot Menu Boot Settings ConfigurationBoot Device Priority OS InstallationSecurity Menu Removeable DrivesExit Menu Page Amibios Error Beep Codes Appendix a Bios Error Beep CodesBeep Code Error Message Description AS1020C-3 User’s Manual Appendix B Bios Post Checkpoint Codes Uncompressed Initialization CodesBootblock Recovery Codes Uncompressed Initialization Codes AS1020C-3 User’s Manual Appendix B Bios Post Checkpoint Codes AS1020C-3 User’s Manual A9h Aah Abh B0h B1h 00h AS1020C-3 User’s Manual Appendix C System Specifications Weight Power SupplyServerboard ChassisRegulatory Compliance