StorCase Technology DS100 manual Appendix a Specifications/Dimensions

Page 29

20

Appendix A - Specifications/Dimensions

 

 

Appendix A - Specifications/Dimensions

The following Data Silo DS100 specifications and dimensions are provided for reference only.

Environmental Specifications

 

Operating

Storage

 

 

 

Ambient Temperature

0° C to 40° C

-40° C to 70° C

Relative Humidity(1)

10% to 80%

10% to 90%

 

 

 

Altitude

-1000 to 10,000 ft

-1000 to 40,000 ft

 

-305m to 3048m

-305m to 12195m

Shock (2)

10g

60g

 

 

 

(1)Non-condensing with maximum gradient of 10% per hour.

(2)11 msec pulse width 1/2 sine wave.

Physical

 

 

 

Specifications

DS100 1-Bay

DS100 2-Bay

DS100 4-Bay

Height

2.70" (68.6mm)

4.28" (108.7mm)

10.27" (260.8mm)

Width

9.50" (241.3mm)

9.50" (241.3mm)

7.54" (191.5mm)

Depth

11.35" (288.3mm)

11.35" (288.3mm)

11.35" (288.3mm)

Drive Mounting

9.75" (247.7mm)

9.75" (247.7mm)

9.75" (247.7mm)

Depth

 

 

 

Actual Weight

6.4lb. (2.91kg)

8.2lb (3.73kg)

18.6lb (8.45kg)

 

 

 

 

Chassis Reliability/Maintainability

MTBF

500,000 Hours

MTTR

5 Minutes

 

 

Preventive

None

Maintenance

 

 

 

DS100 Fan Air Flow (Maximum)

1-Bay

2-Bay

4-Bay

 

 

 

17 CFM

36 CFM

72 CFM

(60mm, 1ea.) (80mm, 1ea.) (80mm, 2ea.)

Electrical

DS100 1-Bay

DS100 2-Bay

DS100 4-Bay

Input

90-260 VAC, Auto

90-260 VAC, Auto

90-260 VAC, Auto

 

Select, 47-60Hz

Select, 47-60Hz

Select, 47-60Hz

 

 

 

 

DC Output

 

 

 

(Continuous)

40 watts

65 watts

130 watts

 

 

 

 

DC Output (Peak )

60 watts

135 watts

270 watts

 

 

 

 

 

 

 

 

StorCase Technology, Inc.

DS100 (U320) User's Guide - Rev. A02

Image 29
Contents Data Silo DS100 Part No. D89-0000-0208 A02 May Data Silo DS100Limited Warranty Free Technical Support CSA NRTL/C TUV Declaration of ConformityRadiofrequencyinterferencestatement Federal Communications Commission FCC StatementWichtige Sicherheitshinweise Important Safety InstructionsTable of Contents List of Figures contd Scsi ID Selection SwitchesSerial Number Packaging InformationData Silo DS100 Family General DescriptionOn LED DS100 Front Panel DS100 2-Bay Shown Front PanelDS100 Rear Panel DS100 2-Bay Shown DS100 Rear PanelRemoving the DS100 Cover Installing the Drives into the DS100Removing the Cover Bay Shown Drive PreparationRow If Installing a 8-BIT Scsi DeviceTypical Drive 16-Bit Single-Ended ID Select Pins If Installing a 16-BIT Scsi DeviceIf Installing a Drive Into the DS100 1-BAY or DS100 2-BAY Drive InstallationRemoving the Drive Mounting Bracket DS100 2-Bay Shown 0539 0541A If Installing a Drive Into the DS100 4-BAY Page Selecting the Scsi ID Number Scsi ID Selection SwitchHost Controller Connecting the DS100 to the Computer SystemThis Page Left Blank Intentionally Appendices Environmental Specifications Operating Storage Appendix a Specifications/DimensionsAppendix a Specifications/Dimensions Figure B-1 Removing the Fuse Appendix B Fuse RemovalReaders Comments S I N E S S R E P LY M a I L