Seagate manual Installing the ST19171FC drive, Providing adequate cooling

Page 14

12

Barracuda 9FC Installation Guide, Rev. A

Installing the ST19171FC drive

To install a ST19171FC drive, simply plug the drive directly into your system’s Fibre Channel backpanel 40-pin single connector attachment (FC-SCA). There are no jumpers or terminators on the drive, and power is supplied through the connector. Table 1 on page 21 lists the pin descriptions of the 40-pin FC-SCA.

Read the following general information topics to ensure your drive is installed properly:

Providing adequate cooling

Mounting the drive

Formatting the drive

Providing adequate cooling

The enclosure design must ensure adequate cooling for the drive. The maximum ambient temperature is 50oC (122oF). The maximum allowable head and disc assembly (HDA) case tem- perature is 60oC (140oF).

The drive’s product manual (83329100) describes how to evalu- ate the air-flow design. The evaluation consists of ensuring that the temperatures of certain critical components remain within acceptable limits during drive operation.

We recommend orienting the drive or directing the air flow in a way that creates the least amount of air-flow resistance while providing air flow above the circuit boards and around the head and disc assembly (HDA). Also, choose the shortest possible path between the air inlet and exit. This minimizes the distance traveled by air that is heated by the drive and by other nearby heat sources.

Image 14
Contents Barracuda 9FC Contents Preface Electrostatic discharge protectionImportant safety information and precautions Page Wichtige Sicherheitshinweise Barracuda 9FC Installation Guide, Rev. a Barracuda 9FC Installation Guide, Rev. a Page CompuServe forum Technical support servicesSeaFAX USA 1-800-SEAGATE England 44-1-62-847-7080 Australia SeaFONE 1-800-SEAGATESeaBOARD location Modem number SeaTDD 408SeaBOARD General description Barracuda 9FC disc driveCharacteristics ST19171FC Installing the ST19171FC drive Providing adequate coolingKühlung des Systems Suggested air flow Abbildung 2. Empfohlener Luftstromverlauf Installation des Laufwerkes Mounting the driveDImensions Abbildung 3 Laufwerkabmessungen 101.60 250 Enabling write cache Inserting the driveFormatting the drive Connecting remote LEDs LED indicator connector J6 FC-SCA pin descriptions SEL2 Troubleshooting General installation troubleshootingPage