Seagate ST973451FC, ST936751FC manual Vibration, Air cleanliness, Corrosive environment

Page 42

6.4.4.2Vibration

a. Operating—normal

The drive as installed for normal operation, shall comply with the complete specified performance while subjected to continuous vibration not exceeding

10-500 Hz @ 1.0 G (zero to peak)

Vibration may be applied in the X, Y, or Z axis.

Operating normal translational random flat profile

10 - 400 Hz

0.4 GRMS

b.Operating—abnormal

Equipment as installed for normal operation shall not incur physical damage while subjected to periodic vibration not exceeding:

15 minutes of duration at major resonant frequency 10-500 Hz @ 1.5 G (X, Y, or Z axis)

Vibration occurring at these levels may degrade operational performance during the abnormal vibration period. Specified operational performance will continue when normal operating vibration levels are resumed. This assumes system recovery routines are available.

Operating abnormal translational random flat profile

10 - 500 Hz

1.2 GRMS

c.Non-operating

The limits of non-operating vibration shall apply to all conditions of handling and transportation. This includes both isolated drives and integrated drives.

The drive shall not incur physical damage or degraded performance as a result of continuous vibration not exceeding

5-22 Hz @ 0.040 inches (1.02 mm) displacement (zero to peak) 20-500 Hz @ 3.0 G (zero to peak)

Vibration may be applied in the X, Y, or Z axis.

Non-operating translational random flat profile

10 - 500 Hz

1.2 GRMS

6.4.5Air cleanliness

The drive is designed to operate in a typical office environment with minimal environmental control.

6.4.6Corrosive environment

Seagate electronic drive components pass accelerated corrosion testing equivalent to 10 years exposure to light industrial environments containing sulfurous gases, chlorine and nitric oxide, classes G and H per ASTM B845. However, this accelerated testing cannot duplicate every potential application environment.

Users should use caution exposing any electronic components to uncontrolled chemical pollutants and corro- sive chemicals as electronic drive component reliability can be affected by the installation environment. The sil- ver, copper, nickel and gold films used in Seagate products are especially sensitive to the presence of sulfide, chloride, and nitrate contaminants. Sulfur is found to be the most damaging. In addition, electronic components should never be exposed to condensing water on the surface of the printed circuit board assembly (PCBA) or exposed to an ambient relative humidity greater than 95%. Materials used in cabinet fabrication, such as vulca- nized rubber, that can outgas corrosive compounds sshould be minimized or eliminated. The useful life of any electronic equipment may be extended by replacing materials near circuitry with sulfide-free alternatives.

34

Savvio 15K.1 FC Product Manual, Rev. B

Image 42
Contents Savvio 15K.1 FC ST973451FC ST936751FCPage Contents Installation Physical/electrical specificationsDefect and error management Interface requirementsSeagate Technology support services Savvio 15K.1 FC Product Manual, Rev. B List of Figures Page Scope Savvio 15K.1 family disc driveSavvio 15K.1 FC Product Manual, Rev. B Electromagnetic compatibility Applicable standards and reference documentationStandards Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS Reference documents Ncits TR-19Savvio 15K.1 FC Product Manual, Rev. B General description Standard features Reliability Media descriptionPerformance Formatted capacitiesFactory-installed accessories OptionsProgrammable drive capacity Seek performance characteristics Performance characteristicsInternal drive characteristics Access timeFormat command execution time General performance characteristicsStart/stop time Prefetch/multi-segmented cache control Cache operationCaching write data Prefetch operation Reliability specifications Error ratesRecoverable Errors Seek errors Reliability and serviceUnrecoverable Errors Interface errorsHot plugging the drive 4 S.M.A.R.TControlling S.M.A.R.T Determining rate Performance impactReporting control Predictive failuresDrive Self Test DST Temperature Log Page 0DhParameter Code Description DST failure definitionInvoking DST State of the drive prior to testingImplementation Short and extended testsAbort Product warrantyLog page entries ShippingProduct repair and return information Physical/electrical specifications AC power requirementsDC power requirements General DC power requirement notes Current profiles Power sequencingConducted noise immunity +5V +12VTypical ST936751FC drive +12V and +5V current profiles Power dissipation CURRENT/POWER vs Throughput FC 1GB Random 8 Block ReadsST973451FC CURRENT/POWER vs Throughput FC 4GB Random 8 Block Reads FC CURRENT/POWER vs Throughput FC 1GB Random 8 Block Reads ST936751FCTemperature FC CURRENT/POWER vs Throughput FC 4GB Random 8 Block ReadsEnvironmental limits Shock and vibration Relative humidityEffective altitude sea level ShockPackage size Packaged/product weight Drop height Recommended mounting Air cleanliness VibrationCorrosive environment Acoustics Mechanical specifications Drive dimensions inchesDefect and error management Drive internal defects/errorsDrive error recovery procedures FC-AL system errors Background Media Scan Media Pre-ScanDeferred Auto-Reallocation Idle Read After Write Installation Drive orientationCooling Drive mounting GroundingLink services supported Type of frame FC-AL featuresFibre Channel link service frames Interface requirementsFibre Channel Scsi FCP task management functions Fibre Channel task management functionsFibre Channel task management responses Task name SupportedFibre Channel port login NPort login Plogi payload BytesNPort Login Accept ACC payload Bytes Fibre Channel port login acceptFibre Channel Process Login Process Login Plri payloadProcess Login Accept ACC payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Fabric Login Flogi payload BytesFibre Channel fabric accept login Fabric Login Accept ACC payload BytesFC-AL options supported Dual port supportFibre Channel Arbitrated Loop options Option SupportedScsi commands supported Supported commands Command code Command nameDisconnect/reconnect control page 02h Savvio 15K.1 FC Product Manual, Rev. B LBdata Supported commands Command code Supported 4 Command name Inquiry data Savvio inquiry data Bytes Data hexSupported Feature or condition Miscellaneous operating features and conditionsMiscellaneous features Miscellaneous statusPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Part description Positions Part number FeaturesElectrical description FC-SCA pin descriptions Pin Signal name Signal type Pin Signal name Signal typePin descriptions Power Fault LED OutFC-AL transmitters and receivers Enable port bypass signals Active LED OutMotor start controls Parallel Enclosure Services Interface ESI 11 SEL6 through SEL0 ID linesSetting Arbitrated loop physical address Alpa valuesHex Dec Signal characteristics TTL input characteristicsDevice control codes Differential Pecl output Differential Pecl inputSavvio 15K.1 FC Product Manual, Rev. B Presales Support Seagate Technology support servicesInternet Technical SupportWarranty Service Data Recovery Services Authorized Service CentersData Recovery Services Call Center Toll-free Direct dial Index NumericsFAN Page Plogi SEL ID See also cooling