Seagate ST936751FC Interface requirements, FC-AL features, Fibre Channel link service frames

Page 51

9.0Interface requirements

This section partially describes the interface requirements as implemented on Savvio drives. Additional infor- mation is provided in the Fibre Channel Interface Manual (part number 100293070).

9.1FC-AL features

This section lists the Fibre Channel-specific features supported by Savvio drives.

9.1.1Fibre Channel link service frames

Table 5 lists the link services supported by Savvio drives.

Table 5:

Link services supported

 

 

 

Type of frame

Link service

 

 

Basic link service frames

Abort Sequence (ABTS)

 

 

Basic link service reply frames

Basic_Accept (BA_ACC)

 

 

Basic_Reject (BA_RJT)

 

 

Extended link service frames

N_Port Login (PLOGI)

 

 

Fabric Login (FLOGI)

 

 

Logout (LOGO)

 

 

Process Login (PRLI)

 

 

Process Logout (PRLO)

 

 

Read Link Status (RLS)

 

 

Fabric Address Notification (FAN)

 

 

Port Discovery (PDISC)

 

 

Address Discovery (ADISC)

 

 

Third-party Process Logout (TRPLO)

 

 

Extended link service reply frames

Accept (ACC)

 

 

Link Service Reject (LS_RJT)

Fibre Channel Services

Register FC-4 Types (RFT_ID)

Savvio 15K.1 FC Product Manual, Rev. B

43

Image 51
Contents ST973451FC ST936751FC Savvio 15K.1 FCPage Contents Interface requirements Physical/electrical specificationsDefect and error management InstallationSeagate Technology support services Savvio 15K.1 FC Product Manual, Rev. B List of Figures Page Savvio 15K.1 family disc drive ScopeSavvio 15K.1 FC Product Manual, Rev. B Electromagnetic susceptibility Applicable standards and reference documentationStandards Electromagnetic compatibilityEuropean Union Restriction of Hazardous Substances RoHS Ncits TR-19 Reference documentsSavvio 15K.1 FC Product Manual, Rev. B General description Standard features Formatted capacities Media descriptionPerformance ReliabilityFactory-installed accessories OptionsProgrammable drive capacity Access time Performance characteristicsInternal drive characteristics Seek performance characteristicsFormat command execution time General performance characteristicsStart/stop time Prefetch/multi-segmented cache control Cache operationCaching write data Prefetch operation Reliability specifications Error ratesRecoverable Errors Interface errors Reliability and serviceUnrecoverable Errors Seek errorsHot plugging the drive 4 S.M.A.R.TControlling S.M.A.R.T Predictive failures Performance impactReporting control Determining rateDST failure definition Temperature Log Page 0DhParameter Code Description Drive Self Test DSTShort and extended tests State of the drive prior to testingImplementation Invoking DSTShipping Product warrantyLog page entries AbortProduct repair and return information Physical/electrical specifications AC power requirementsDC power requirements General DC power requirement notes +5V +12V Power sequencingConducted noise immunity Current profilesTypical ST936751FC drive +12V and +5V current profiles Power dissipation CURRENT/POWER vs Throughput FC 1GB Random 8 Block ReadsST973451FC CURRENT/POWER vs Throughput FC 4GB Random 8 Block Reads ST936751FC FC CURRENT/POWER vs Throughput FC 1GB Random 8 Block ReadsTemperature FC CURRENT/POWER vs Throughput FC 4GB Random 8 Block ReadsEnvironmental limits Shock Relative humidityEffective altitude sea level Shock and vibrationPackage size Packaged/product weight Drop height Recommended mounting Air cleanliness VibrationCorrosive environment Acoustics Drive dimensions inches Mechanical specificationsDefect and error management Drive internal defects/errorsDrive error recovery procedures FC-AL system errors Background Media Scan Media Pre-ScanDeferred Auto-Reallocation Idle Read After Write Installation Drive orientationCooling Grounding Drive mountingInterface requirements FC-AL featuresFibre Channel link service frames Link services supported Type of frameTask name Supported Fibre Channel task management functionsFibre Channel task management responses Fibre Channel Scsi FCP task management functionsNPort login Plogi payload Bytes Fibre Channel port loginProcess Login Plri payload Fibre Channel port login acceptFibre Channel Process Login NPort Login Accept ACC payload BytesFabric Login Flogi payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Process Login Accept ACC payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginOption Supported Dual port supportFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Command code Command name Scsi commands supportedDisconnect/reconnect control page 02h Savvio 15K.1 FC Product Manual, Rev. B LBdata Supported commands Command code Supported 4 Command name Savvio inquiry data Bytes Data hex Inquiry dataMiscellaneous status Miscellaneous operating features and conditionsMiscellaneous features Supported Feature or conditionPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Part description Positions Part number FeaturesElectrical description FC-SCA pin descriptions Pin Signal name Signal type Pin Signal name Signal typePin descriptions Power Fault LED OutFC-AL transmitters and receivers Enable port bypass signals Active LED OutMotor start controls 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESISetting Arbitrated loop physical address Alpa valuesHex Dec Signal characteristics TTL input characteristicsDevice control codes Differential Pecl input Differential Pecl outputSavvio 15K.1 FC Product Manual, Rev. B Technical Support Seagate Technology support servicesInternet Presales SupportWarranty Service Data Recovery Services Authorized Service CentersData Recovery Services Call Center Toll-free Direct dial Numerics IndexFAN Page Plogi SEL ID See also cooling