9.1.9Fibre Channel fabric accept login

Table 13 lists the required content of the Fabric Login Accept (ACC) payload from the fabric.

Table 13: Fabric Login Accept (ACC) payload

Bytes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-15

02

00

00

00

09

09

BB

BB

CF

XX

FS

FS

R_

A_

T0

V_

Common

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16-31

E_

D_

T0

V_

PN

PN

PN

PN

PN

PN

PN

PN

NN

NN

NN

NN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32-35

NN

NN

NN

NN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36-47

 

 

 

 

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

Class 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48-51

XX

XX

XX

XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52-63

 

 

 

 

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

Class 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64-67

XX

XX

XX

XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68-79

 

 

 

 

SO

SO

xx

xx

XX

XX

FS

FS

XX

xx

XX

XX

Class 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80-83

OS

OS

XX

XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

84-95

 

 

 

 

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

96-99

XX

XX

XX

XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100-111

 

 

 

 

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

Vendor -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

112-115

XX

XX

XX

XX

 

 

 

 

 

 

 

 

 

 

 

 

Version

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XIndicates a four-bit (hex) field is not checked.

x Indicates a single bit is not checked.

BB BB-Credit. This field is not checked. The FC-AL drive uses BB-Credit of zero (0).

CF

Common features. This binary field selects the common features requested by the fabric login.

 

MSB

Continuously increasing offset

x

 

 

Random relative offset

x

 

 

Valid version level

x

 

 

N_Port/F_Port

Must = 1, F_Port

 

 

Alternate credit model

Must = 1

 

 

Other bits reserved

xxx XX

FS

Receive buffer field size. The FS field in the common and Class 3 parameters is checked for the range 128 < FS < 2,112 and a

 

multiple of four bytes. The receive buffer field size in the Class 3 parameters is used. The drive uses the lower FS of Fabric

 

Login Accept or N_Port Login when sending frames to an initiator.

PN

Port Name. The fabric port name is saved with the login parameters. If a change of the port name is detected during a FAN, an

 

implicit logout occurs and a LS_RJT is returned to the fabric.

NN

Node Name. The drive does not check or save the node name.

SO

Service Options—Class 3 only.

 

 

MSB

Class valid

Must = 1

 

 

Intermix

x

 

 

Stacked connection req.

xx

 

 

Sequential delivery

Must = 1

 

 

Other bits reserved

xxx XX

48

Savvio 15K.1 FC Product Manual, Rev. B

Image 56
Contents Savvio 15K.1 FC ST973451FC ST936751FCPage Contents Physical/electrical specifications Defect and error managementInstallation Interface requirementsSeagate Technology support services Savvio 15K.1 FC Product Manual, Rev. B List of Figures Page Scope Savvio 15K.1 family disc driveSavvio 15K.1 FC Product Manual, Rev. B Applicable standards and reference documentation StandardsElectromagnetic compatibility Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS Reference documents Ncits TR-19Savvio 15K.1 FC Product Manual, Rev. B General description Standard features Media description PerformanceReliability Formatted capacitiesProgrammable drive capacity Factory-installed accessoriesOptions Performance characteristics Internal drive characteristicsSeek performance characteristics Access timeStart/stop time Format command execution timeGeneral performance characteristics Caching write data Prefetch/multi-segmented cache controlCache operation Prefetch operation Recoverable Errors Reliability specificationsError rates Reliability and service Unrecoverable ErrorsSeek errors Interface errorsControlling S.M.A.R.T Hot plugging the drive4 S.M.A.R.T Performance impact Reporting controlDetermining rate Predictive failuresTemperature Log Page 0Dh Parameter Code DescriptionDrive Self Test DST DST failure definitionState of the drive prior to testing ImplementationInvoking DST Short and extended testsProduct warranty Log page entriesAbort ShippingProduct repair and return information DC power requirements Physical/electrical specificationsAC power requirements General DC power requirement notes Power sequencing Conducted noise immunityCurrent profiles +5V +12VTypical ST936751FC drive +12V and +5V current profiles ST973451FC Power dissipationCURRENT/POWER vs Throughput FC 1GB Random 8 Block Reads CURRENT/POWER vs Throughput FC 4GB Random 8 Block Reads FC CURRENT/POWER vs Throughput FC 1GB Random 8 Block Reads ST936751FCEnvironmental limits TemperatureFC CURRENT/POWER vs Throughput FC 4GB Random 8 Block Reads Relative humidity Effective altitude sea levelShock and vibration ShockPackage size Packaged/product weight Drop height Recommended mounting Corrosive environment Air cleanlinessVibration Acoustics Mechanical specifications Drive dimensions inchesDrive error recovery procedures Defect and error managementDrive internal defects/errors FC-AL system errors Deferred Auto-Reallocation Background Media ScanMedia Pre-Scan Idle Read After Write Cooling InstallationDrive orientation Drive mounting GroundingFC-AL features Fibre Channel link service framesLink services supported Type of frame Interface requirementsFibre Channel task management functions Fibre Channel task management responsesFibre Channel Scsi FCP task management functions Task name SupportedFibre Channel port login NPort login Plogi payload BytesFibre Channel port login accept Fibre Channel Process LoginNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel Process Login Accept Fibre Channel fabric loginProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFibre Channel fabric accept login Fabric Login Accept ACC payload BytesDual port support Fibre Channel Arbitrated Loop optionsFC-AL options supported Option SupportedScsi commands supported Supported commands Command code Command nameDisconnect/reconnect control page 02h Savvio 15K.1 FC Product Manual, Rev. B LBdata Supported commands Command code Supported 4 Command name Inquiry data Savvio inquiry data Bytes Data hexMiscellaneous operating features and conditions Miscellaneous featuresSupported Feature or condition Miscellaneous statusPhysical description Physical characteristicsFC-AL physical interface Electrical description Connector requirementsPart description Positions Part number Features Pin descriptions FC-SCA pin descriptions Pin Signal name Signal typePin Signal name Signal type FC-AL transmitters and receivers PowerFault LED Out Motor start controls Enable port bypass signalsActive LED Out Parallel Enclosure Services Interface ESI 11 SEL6 through SEL0 ID linesHex Dec SettingArbitrated loop physical address Alpa values Device control codes Signal characteristicsTTL input characteristics Differential Pecl output Differential Pecl inputSavvio 15K.1 FC Product Manual, Rev. B Seagate Technology support services InternetPresales Support Technical SupportData Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Index NumericsFAN Page Plogi SEL ID See also cooling