2.9Environmental specifications
2.9.1Ambient temperature
Ambient temperature is defined as the temperature of the environment immediately surrounding the drive. Actual drive case temperature should not exceed 75°C (167°F) within the operating ambient conditions. Rec- ommended measurement locations are shown in Figure 6 on page 25.
Above 1,000 feet (305 meters), the maximum temperature is derated linearly to 112°F (44°C) at 10,000 feet (3,048 meters).
Operating |
|
ST3320820ACE, ST3300820ACE and ST3250820ACE | 0° to 65°C (32° to 149°F) |
ST3500830ACE and ST3400820ACE | 0° to 62°C (32° to 143.6°F) |
ST3750840ACE | 0° to 60°C (32° to 140°F) |
|
|
Nonoperating | |
|
|
2.9.2Temperature gradient
Operating | 20°C per hour (68°F per hour max), without condensation |
|
|
Nonoperating | 30°C per hour (86°F per hour max) |
|
|
2.9.3Humidity
2.9.3.1Relative humidity
Operating | 5% to 90% noncondensing (30% per hour max) |
|
|
Nonoperating | 5% to 95% noncondensing (30% per hour max) |
|
|
2.9.3.2Wet bulb temperature
Operating | 37.7°C (99.9°F max) |
|
|
Nonoperating | 37.7°C (99.9°F max) |
|
|
2.9.4Altitude
Operating | |
|
|
Nonoperating | |
|
|
14 | DB35.3 Series PATA Product Manual, Rev. C |