2.9.5Shock
All shock specifications assume that the drive is mounted securely with the input shock applied at the drive mounting screws. Shock may be applied in the X, Y or Z axis.
2.9.5.1Operating shock
These drives comply with the performance levels specified in this document when subjected to a maximum operating shock of 63 Gs based on
2.9.5.2Nonoperating shock
2 Disc models
The nonoperating shock level that the drive can experience without incurring physical damage or degradation in performance when subsequently put into operation is 350 Gs based on a nonrepetitive
3 and 4 Disc models
The nonoperating shock level that the drive can experience without incurring physical damage or degradation in performance when subsequently put into operation is 300 Gs based on a nonrepetitive
2.9.6Vibration
All vibration specifications assume that the drive is mounted securely with the input vibration applied at the drive mounting screws. Vibration may be applied in the X, Y or Z axis.
2.9.6.1Operating vibration
The following table lists the maximum vibration levels that the drive may experience while meeting the perfor- mance standards specified in this document.
0.25 | Gs (Limited displacement) | |
|
| |
0.50 Gs | ||
|
|
|
0.25 | Gs | |
|
|
|
2.9.6.2Nonoperating vibration
The following table lists the maximum nonoperating vibration that the drive may experience without incurring physical damage or degradation in performance when subsequently put into operation.
0.25 Gs (limited displacement) | |
|
|
5.0 Gs | |
|
|
1.0 Gs | |
|
|
DB35.3 Series PATA Product Manual, Rev. C | 15 |