Seagate ST340015ACE manual Drive as master with a non-ATA-compatible slave, Cable select option

Page 31

Barracuda 5400.1 Product Manual, Rev. G

23

3.3Jumper settings

3.3.1Master/slave configuration

The options jumper block shown in Figure 4 is used to configure the drive for operation. It is the 8-pin dual header between the interface connector and the power connector. Use the following settings to configure the drive as a master or a slave.

Master or single drive. The drive is configured at the factory for a master or single-drive operation with a jumper set on pins 7 and 8.

Drive as slave. Remove all jumpers.

Drive as master with a non-ATA-compatible slave.

Set a jumper on pins 5 and 6 and another jumper on pins 7 and 8. Use this jumper setting only if the drive does not work as a master with no jumpers installed.

Options jumper block

Master or single drive

Drive is slave

Master with non ATA- compatible slave

Cable select

7 5 3 1

8 6 4 2

Figure 4. Master/slave jumper settings

3.3.2Cable select option

Computers that use cable select determine the master and slave drives by selecting or deselecting pin 28, CSEL, on the interface bus. Master and slave drives are determined by their physical position on the cable. To enable cable select, set a jumper on pins 5 and 6 as shown in Figure 4. Refer to your computer manual to determine whether your computer supports this option.

Image 31
Contents Page Page Page Page Contents Barracuda 5400.1 Product Manual, Rev. G Seagate Technology support servicesList of Figures Barracuda 5400.1 Product Manual, Rev. G Introduction Barracuda 5400.1 Product Manual, Rev. G Specification summary table Drive specificationsDrive specification ST340015ACE 50,000 Humidity SeaShield LBA mode Default logical geometryPhysical organization ATA Physical characteristicsTypical seek times msec Read Write Power specificationsSeek time Start/stop timesRead/write power and current Barracuda 5400.1 Product Manual, Rev. G Power consumptionSpinup power Seek modeBarracuda 5400.1 Product Manual, Rev. G Typical 5V startup and operation current profile Conducted noise Power-management modesActive mode Idle modeIdle and Standby timers Sleep modeEnvironmental specifications Ambient temperature Altitude Temperature gradientWet bulb temperature Humidity Relative humidityVibration Barracuda 5400.1 Product Manual, Rev. G ShockOperating shock Nonoperating shockModel Idle Quiet seek Performance seek Acoustic modeAcoustics Fluid Dynamic Bearing FDB motor acousticsPerformance Reference Test Description Level Standard ReliabilityElectromagnetic compatibility Agency certification Safety certificationKorean RRL FCC verification Barracuda 5400.1 Product Manual, Rev. G Handling and static discharge precautions Configuring and mounting the driveBreather filter hole location Breather filter hole precautionsCable select option Drive as master with a non-ATA-compatible slaveSlave Ultra ATA/100 cableDrive mounting MasterMounting dimensions-top, side and end view Barracuda 5400.1 Product Manual, Rev. G ATA interface ATA interface signals and connector pinsO pins and supported ATA signals EC H Command name Command code in hex ATA-standard commandsCommand name Command code in hex ATA-standard security commands Identify Device command0C5AH Word Description ValueXxxxH Xx3FH Description if bit is set to Bit 0CH Set Features commandF1H Report full capacity available Code in features Register A.R.T. command 4 S.M.A.R.T. commandsInternet MySeagate Seagate Technology support services Online Services40Barracuda 5400.1 Product Manual, Rev. G Automated Phone ServicesUSA/Canada/Latin America Support Services Africa/Middle East Support Services European Support ServicesAsia/Pacific Support Services Barracuda 5400.1 Product Manual, Rev. G Index GMR Barracuda 5400.1 Product Manual, Rev. G 48Barracuda 5400.1 Product Manual, Rev. G Page Seagate Technology LLC