Seagate ST3600057FC manual FC-AL system errors, These values are subject to change

Page 46

Table 5: Read and write retry count maximum recovery times [1]

Read retry

Maximum recovery time per LBA

count

(cumulative, msec)

 

 

0

51.87

 

 

1

59.85

 

 

2

203.49

 

 

3

231.42

 

 

4

295.26

 

 

5

327.18

 

 

6

359.10

 

 

7

446.88

 

 

8

538.65

 

 

9

570.57

 

 

10

598.50

 

 

11 (default)

1,534.97

 

 

[1]These values are subject to change.

Write retry

Maximum recovery time per LBA

count

(cumulative, msec)

 

 

0

23.94

 

 

1

35.91

 

 

2

39.9

 

 

3

51.87

 

 

4

79.8

 

 

5 (default)

107.73

 

 

Setting these retry counts to a value below the default setting could result in an increased unrecovered error rate which may exceed the value given in this product manual. A setting of zero (0) will result in the drive not performing error recovery.

For example, suppose the Read/Write Recovery page has the RC bit set to 0, read retry count set to 4, and the recovery time limit field (Mode Sense page 01, bytes 10 and 11) set to FF FF hex (maximum). A four LBA Read command is allowed to take up to 253.11 msec recovery time for each of the four LBAs in the command. If the recovery time limit is set to 00 C8 hex (200 msec decimal) a four LBA read command is allowed to take up to 200 msec for all error recovery within that command. The use of the Recovery Time Limit field allows finer granularity on control of the time spent in error recovery. The recovery time limit only starts counting when the drive is executing error recovery and it restarts on each command. Therefore, each command’s total recovery time is subject to the recovery time limit. Note: A recovery time limit of 0 will use the drive’s default value of FF FF. Minimum recovery time limit is achieved by setting the Recovery Time Limit field to 00 01.

8.3FC-AL system errors

Information on the reporting of operational errors or faults across the interface is given in the Fibre Channel Interface Manual. The FCP Response returns information to the host about numerous kinds of errors or faults. The Receive Diagnostic Results reports the results of diagnostic operations performed by the drive.

Status returned by the drive to the initiator is described in the Fibre Channel Interface Manual. Status reporting plays a role in systems error management and its use in that respect is described in sections where the various commands are discussed.

40

Cheetah 15K.7 FC Product Manual, Rev. A

Image 46
Contents Cheetah 15K.7 FC Standard models Self-Encrypting Drive modelsPage Contents About self-encrypting drives Defect and error managementInstallation Interface requirementsSeagate Technology support services Cheetah 15K.7 FC Product Manual, Rev. a Scope Model Number Capacity Self-Encrypting Drive SEDElectromagnetic compatibility Applicable standards and reference documentationStandards Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS Reference documents Ncits TR-20General description Standard features Reliability Media descriptionPerformance Formatted capacitiesUser-installed accessories Factory-installed optionsProgrammable drive capacity Seek performance characteristics Performance characteristicsInternal drive characteristics Access timeStart/stop time General performance characteristicsPrefetch/multi-segmented cache control Cache operation Caching write dataPrefetch operation Recoverable Errors Reliability specificationsError rates Unrecoverable ErrorsInterface errors Reliability and serviceSeek errors Preventive maintenancePerformance impact 4 S.M.A.R.TControlling S.M.A.R.T MillisecondsPredictive failures Temperature Log Page 0DhDetermining rate Thermal monitorDST failure definition State of the drive prior to testingDrive Self Test DST ImplementationExtended test Function Code 010b Short and extended testsShort test Function Code 001b Log page entriesShipping Product warrantyProduct repair and return information AC power requirements Physical/electrical specificationsDC power requirements ST3600057FC DC power requirements Gbit Amps ST3450857FC DC power requirements Gbit AmpsGeneral DC power requirement notes ST3300657FC DC power requirements Gbit AmpsConducted noise immunity Power sequencingCurrent profiles Typical ST3450857FC current profiles Typical ST3300657FC current profiles Power dissipation 600GB model450GB models Environmental limits Temperature a. Operating300GB models Relative humidity Effective altitude sea level a. OperatingShock and vibration Package size Packaged/product weight Drop heightShock Recommended mounting Acoustics Air cleanlinessVibration a. Operating-normal Corrosive environmentRoHS compliance statement Electromagnetic susceptibility See SectionMechanical specifications Mounting configuration dimensionsAbout self-encrypting drives Controlled accessAdmin SP Data encryptionDrive locking Default passwordRandom number generator RNG Data bandsSupported commands Authenticated firmware downloadPower requirements Cryptographic eraseDrive internal defects/errors Defect and error managementDrive error recovery procedures Page FC-AL system errors These values are subject to changeMedia Pre-Scan Background Media ScanDeferred Auto-Reallocation Idle Read After Write Drive ID/option selection InstallationDrive orientation Cooling Air flowDrive mounting GroundingLink services supported Type of frame FC-AL featuresFibre Channel link service frames Interface requirementsFibre Channel task management responses Fibre Channel task management functionsFC Scsi FCP response codes Function name Response code Fibre Channel port login NPort login Plogi payload BytesNPort Login Accept ACC payload Bytes Fibre Channel port login acceptProcess Login Plri payload Process Login Accept ACC payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Fabric Login Flogi payload BytesFibre Channel fabric accept login Fabric Login Accept ACC payload BytesFibre Channel Arbitrated Loop options Scsi commands supportedDual port support FC-AL options supportedSupported commands Cheetah 15K.7 FC Product Manual, Rev. a Cheetah 15K.7 FC Product Manual, Rev. a Background Medium Scan 15h Inquiry data Mode Sense dataCheetah 15K.7 FC inquiry data Bytes Data hex Page Mode Data Header Block Descriptor Ec b2 5c 00 00 02 Supported Feature or condition Miscellaneous operating features and conditionsMiscellaneous features Miscellaneous statusFC-AL physical interface Physical characteristicsPhysical description Electrical description Connector requirementsPin descriptions Pin Signal name Signal type FC-SCA pin descriptions Pin Signal name Signal typeFC-AL transmitters and receivers Power Fault LED OutActive LED Out Enable port bypass signalsMotor start controls Parallel Enclosure Services Interface ESI 10.5.11 SEL6 through SEL0 ID linesArbitrated loop physical address Alpa values SettingHex Dec TTL input characteristics provides the TTL characteristics Signal characteristicsDevice control codes FC Differential output LED driver signalsFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Presales Support Seagate Technology support servicesTechnical Support Data Recovery Services Authorized Service Centers Warranty ServiceData Recovery Services Call Center Toll-free Direct dial Index NumericsDevctrlcode FCP Mtbf Page See also cooling Page Cheetah 15K.7 FC Product Manual, Rev. a Page Seagate Technology LLC
Related manuals
Manual 90 pages 41.74 Kb