Seagate ST3600057FC manual Active LED Out, Enable port bypass signals, Motor start controls

Page 73

10.5.8Active LED Out

The Active LED Out signal is driven by the drive as indicated in Table 25.

Table 25: Active LED Out conditions

Normal command activity

LED status

 

 

Spun down and no activity

Slow blink (20% on and 80% off a 2 sec cycle)

 

 

Spun down and activity (command executing)

On

 

 

Spun up and no activity

On

 

 

Spun up and activity (command executing)

Off

 

 

Spinning up or down

Blinks steadily (50% on and 50% off)

 

 

Format in progress, each cylinder change

Toggles on/off

 

 

The Active LED Out signal is designed to pull down the cathode of an LED. The anode is attached to the proper +5 volt supply through an appropriate current limiting resistor. The LED and the current limiting resistor are external to the drive.

10.5.9Enable port bypass signals

The – Enable Bypass Port A (– EN BYP Port A) and – Enable Bypass Port B (– EN BYP Port B) signals control the port bypass circuits (PBC) located external to the disc drive. The PBC allows a loop to remain functional in the event of a drive failure or removal. When these signals are active, low, the PBC bypasses the drive on the associated port. When an Enable Bypass signal is active, the corresponding Port Bypass LED signal in con- nector J1 is driven low by the disc drive. A pull down resistor, 1K, located with the PBC should be used to insure the bypass is enabled if the disc drive is not installed.

The Enable Bypass signal is active under failing conditions within the drive, on detection of the Loop Port Bypass primitive sequence, or on removal of the drive. In the bypass state the drive continues to receive on the inbound fibre. Enable Bypass may be deactivated by detection of a Loop Port Enable primitive sequence if the drive has completed self-test and a hardware failure is not present.

Failure modes detected by the disc drive that will enable bypass include:

Transmitter/receiver wrap test failure

Loss of receive clock

Loss of transmission clock

Drive interface hardware error

10.5.10Motor start controls

The drive’s motor is started according to the Start_1 and Start_2 signals described in Table 26. The state of these signals can be wired into the backplane socket or driven by logic on the backplane.

Table 26:

Motor start control signals

 

 

 

 

 

Case

Start_2

Start_1

Motor spin function

 

 

 

 

1

Low

Low

Motor spins up at DC power on.

 

 

 

 

2

High

Low

Motor spins up only when SCSI Start command is received.

 

 

 

 

3

Low

High

Motor spins up after a delay of 12 seconds times the modulo 8 value

 

 

 

of the numeric SEL ID of the drive from DC power on.

 

 

 

 

4

High

High

The drive will not spin up.

 

 

 

 

Cheetah 15K.7 FC Product Manual, Rev. A

67

Image 73
Contents Standard models Self-Encrypting Drive models Cheetah 15K.7 FCPage Contents Installation Defect and error managementAbout self-encrypting drives Interface requirementsSeagate Technology support services Cheetah 15K.7 FC Product Manual, Rev. a Model Number Capacity Self-Encrypting Drive SED ScopeStandards Applicable standards and reference documentationElectromagnetic compatibility Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS Ncits TR-20 Reference documentsGeneral description Standard features Performance Media descriptionReliability Formatted capacitiesUser-installed accessories Factory-installed optionsProgrammable drive capacity Internal drive characteristics Performance characteristicsSeek performance characteristics Access timeStart/stop time General performance characteristicsPrefetch/multi-segmented cache control Caching write data Cache operationPrefetch operation Error rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenanceControlling S.M.A.R.T 4 S.M.A.R.TPerformance impact MillisecondsDetermining rate Temperature Log Page 0DhPredictive failures Thermal monitorDrive Self Test DST State of the drive prior to testingDST failure definition ImplementationShort test Function Code 001b Short and extended testsExtended test Function Code 010b Log page entriesShipping Product warrantyProduct repair and return information AC power requirements Physical/electrical specificationsDC power requirements ST3450857FC DC power requirements Gbit Amps ST3600057FC DC power requirements Gbit AmpsST3300657FC DC power requirements Gbit Amps General DC power requirement notesConducted noise immunity Power sequencingCurrent profiles Typical ST3450857FC current profiles Typical ST3300657FC current profiles 600GB model Power dissipation450GB models Environmental limits Temperature a. Operating300GB models Effective altitude sea level a. Operating Relative humidityShock and vibration Package size Packaged/product weight Drop heightShock Recommended mounting Vibration a. Operating-normal Air cleanlinessAcoustics Corrosive environmentElectromagnetic susceptibility See Section RoHS compliance statementMounting configuration dimensions Mechanical specificationsAdmin SP Controlled accessAbout self-encrypting drives Data encryptionRandom number generator RNG Default passwordDrive locking Data bandsPower requirements Authenticated firmware downloadSupported commands Cryptographic eraseDrive internal defects/errors Defect and error managementDrive error recovery procedures Page These values are subject to change FC-AL system errorsMedia Pre-Scan Background Media ScanDeferred Auto-Reallocation Idle Read After Write Drive ID/option selection InstallationDrive orientation Air flow CoolingGrounding Drive mountingFibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFibre Channel task management responses Fibre Channel task management functionsFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port loginNPort Login Accept ACC payload Bytes Fibre Channel port login acceptProcess Login Plri payload Fibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginDual port support Scsi commands supportedFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Cheetah 15K.7 FC Product Manual, Rev. a Cheetah 15K.7 FC Product Manual, Rev. a Background Medium Scan 15h Inquiry data Mode Sense dataCheetah 15K.7 FC inquiry data Bytes Data hex Page Mode Data Header Block Descriptor Ec b2 5c 00 00 02 Miscellaneous features Miscellaneous operating features and conditionsSupported Feature or condition Miscellaneous statusFC-AL physical interface Physical characteristicsPhysical description Electrical description Connector requirementsPin descriptions Pin Signal name Signal type FC-SCA pin descriptions Pin Signal name Signal typeFC-AL transmitters and receivers Fault LED Out PowerActive LED Out Enable port bypass signalsMotor start controls 10.5.11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIArbitrated loop physical address Alpa values SettingHex Dec TTL input characteristics provides the TTL characteristics Signal characteristicsDevice control codes FC Differential output LED driver signalsFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Presales Support Seagate Technology support servicesTechnical Support Data Recovery Services Authorized Service Centers Warranty ServiceData Recovery Services Call Center Toll-free Direct dial Numerics IndexDevctrlcode FCP Mtbf Page See also cooling Page Cheetah 15K.7 FC Product Manual, Rev. a Page Seagate Technology LLC
Related manuals
Manual 90 pages 41.74 Kb