MT5634 Modem; AT Command Set

Command: &Tn

Loopback Test (V.54 Test) Commands

Values:

n = 0, 1, 3, 6

Default:

None

 

Description:

The modem can perform selected test and diagnostic functions. A

 

test can be run only when the modem is operating in non-error-

 

correction mode (normal or direct mode). For tests 3 and 6, a

 

connection between the two modems must be established. To

 

terminate a test in progress, the escape sequence (+++AT) must

 

be entered.

 

&T0

Stops any test in progress.

 

&T1

Starts a local analog loopback, V.54 Loop 3, test. If a

 

 

connection exists when this command is issued, the

 

 

modem hangs up. When the test starts, a CONNECT

 

 

message is displayed.

 

&T3

Starts local digital loopback, V.54 Loop 2, test. If no

 

 

connection exists, ERROR is returned.

 

&T6

Initiates a remote digital loopback, V.54 Loop 2, test

 

 

without self-test. If no connection exists, ERROR

 

 

is returned.

Command: &V

Display Current Settings

Values:

N/A

 

Description:

Displays the active modem settings.

Command: &Wn Store Current Configuration

Values:

n = 0 or 1

Default:

1

 

Description:

&W0

Stores current modem settings in non-volatile memory

 

 

and causes them to be loaded at power-on or following

 

 

the ATZ command instead of the factory defaults.

 

 

See &F command.

 

&W1

Clears user default settings from non-volatile memory

 

 

and causes the factory defaults to be loaded at power-on

 

 

or following the ATZ command.

Command: &Zy=x Store Dialing Command

Values:

y = 0–2 (0–1SMI-Parallel {internal})

 

x = Dialing command

Default:

None

 

Description:

Stores dialing command x in memory location y. Dial the stored

 

number using the command ATDS=y. See Also the #CBS

 

command, a callback security command.

3-8

Image 16
Contents AT Command Set MT5634Page Table of Contents MT5634 Modem AT Command Set Introduction MT5634 Modem AT Command Set AT Command Summary DescriptionAtmtsmodemcr AT Commands Command Ds Dial Command DS=y Dial Stored Telephone NumberCommand En Echo Command Mode Characters Command Fn Echo Online Data CharactersCommand H n Hook Control Command I n Information RequestCommand M n Monitor Speaker Mode Command N n Modulation HandshakeCommand P Pulse Dialing Command Qn Result Codes Enable/DisableCommand Sr=n Set Register Value Command Sr? Read Register ValueCommand Result Code Options Command Result Code SelectionCommand Zn Modem Reset Command Data Carrier Detect DCD ControlCommand &Dn Data Terminal Ready DTR Control Command &En XON/XOFF Pacing ControlCommand &Fn Load Factory Settings Command &Gn V.22bis Guard Tone ControlCommand Leased Line Operation Command Pulse Dial Make-to-Break Ratio SelectionCommand &Qn Asynchronous Communications Mode Command Data Set Ready DSR ControlCommand &Tn Loopback Test V.54 Test Commands Command &V Display Current SettingsCommand &Wn Store Current Configuration Command &Zy=x Store Dialing CommandCommand \B n Transmit Break Command \A nCommand \K n Break Control Command \Nn Error Correction Mode Selection Command \Qn Flow Control SelectionCommand \Tn Inactivity Timer Command \Vn Protocol Result CodeCommand \Xn XON/XOFF Pass-Through Command Data Calling ToneCommand %An Adaptive Answer Result Code Enable Command View Numbers in BlacklistCommand %DCn AT Command Control Command Fallback and Fall Forward ControlCommand %Hn Direct Connect Enable Command Cisco ConfigurationCommand $EB n Asynchronous Word Length Command $MB n Online BPS SpeedCommand $RP n Ring Priority vs. AT Command Priority Command $SB n Serial Port Baud RateCommand #CBAn Callback Attempts Command +VDR=x, y Distinctive Ring ReportCommand #CBDn Callback Delay Command #CBF? Callback Failed Attempts Display Command #CBFR Callback Failed Attempts ResetCommand #CBIn Local Callback Inactivity Timer Command #CBNy=xCommand #CBSn Callback Enable/Disable Command #Pn Set 11-bit ParityCommand #Sx Enter Setup Password Command #S=x Store Setup PasswordRegister Unit Range Default Description RegistersS37 Decimal Registers MT5634 Modem AT Command Set Result Codes Terse Verbose DescriptionDelayed Remote Configuration and Country Code Configuration Example %%%ATMTSMODEMChanging the Setup Password Country Code Configuration MT5634 Modem AT Command Set Page Sterling Irvine California 949 586-9950 Toll Free