Western Telematic Data/FaxModem manual Registers, Register Default Function

Page 18

RMM User’s Guide

6. S-Registers

Note: To change a setting, use the ATSr=n command, where r is the register and n is a decimal value from 0-255 (unless otherwise indicated).

Register

Default

Function

 

 

 

S0

1

Sets the number of rings on which to answer in Auto

 

 

Answer Mode. When set to 0, Auto Answer is

 

 

disabled. See DIP Switch 5 (Section 4.2).

S1

0

Counts and stores the number of rings from an

 

 

incoming call. Register S0 must be greater than 0.

S2

43

Stores the ASCII decimal code for the escape code

 

 

character. The default character is +. A value of 128-

 

 

255 disables the escape code.

S3

13

Stores the ASCII code for the Carriage Return

 

 

character. Valid range is 0-127.

S4

10

Stores the ASCII decimal code for the Line Feed

 

 

character. Valid range is 0-127.

S5

8

Stores the ASCII decimal code for the Backspace

 

 

character. A value of 128-255 disables the Backspace

 

 

key's delete function.

S6

2

Sets the number of seconds the modem will wait

 

 

before dialing. If Xn is set to X2 or X4, S6

 

 

determines the timeout length when no dial tone is

 

 

detected.

S7

60

Sets the number of seconds the modem will wait for a

 

 

carrier. Often used to select a longer duration when

 

 

the modem is originating an international connection.

S8

2

Sets the duration (in seconds) for the Dial command

 

 

pause option (,).

S9

6

Determines the length of time (in tenths of a second)

 

 

the remote modem’s carrier signal must continue in

 

 

order to be recognized by the RMM.

S10

7

Sets the length of time (in tenths of a second) the

 

 

modem will wait after loss of carrier before hanging

 

 

up. Allows the modem to distinguish between a line

 

 

hit (or other momentary break) from a true disconnect

 

 

(hang up) by the remote modem.

Page 16

Image 18
Contents RMM Sterling Irvine California 949 586-9950 Toll Free Introduction Front PanelFront Panel Indicators Unit DescriptionOperation ATZ3Installation Volt DC Power OptionDip Switch Settings RMM User’s Guide Command Summary Command Function/OptionsDials the specified phone number Sr.b=n Sets result code displayed. Default is Resets modem based on current DIP Switch settings Loads a read-only non-programmable Sets connect speed. If connection cannot be established Begins test modes Zn=s Register Default Function RegistersDefault Function Bit Value Enables ITU-T V.21 modulation at Call Indicate enabled Register Default Specifications PowerCustomer Service Trademark and Copyright Information