Western Telematic RMM-288 Enables ITU-T V.21 modulation at 300 bps, Modem answers both overseas

Page 17

RMM Rack Mount Modem; User's Guide

S18

0

Test timer for &Tn loopback testing. Sets the length of time (in

 

 

seconds) the modem will wait before automatically timing out and

 

 

terminating the test. When set to 0, the timer is disabled. Valid range

 

 

is 1 - 255.

S19

0

Sets the duration (in minutes) for the Inactivity Timer. The timer

 

 

activates when there is no data activity on the phone line. At time out,

 

 

the modem hangs up. S19 = 0 disables the timer.

S20

0

Reserved

S21

10

Sets the length (in 10 millisecond units) of Breaks sent from the

 

 

modem to the computer. Applies to MNP or V.42 mode only.

S22

17

Stores the ASCII decimal code for the XON character.

S23

19

Stores the ASCII decimal code for the XOFF character.

S24

0

Reserved

S25

5

Sets the duration (in hundredths of a second) that DTR must be

 

 

dropped in order to be interpreted as a DTR loss. Allows the modem

 

 

to differentiate between a random glitch and a true DTR loss.

In most cases, the default value can be used. The S25 register is useful for setting compatibility with older systems running under older operating software.

S26

0

Reserved

S27

0

Bit mapped register setup. To set the register, see the instructions for

 

 

S13.

Bit

Value

Result

0

1

Enables ITU-T V.21 modulation at 300 bps

 

 

for overseas calls; in V.21 mode, the

 

 

modem answers both overseas and

 

 

domestic (U.S. And Canada) calls, but only

 

 

originates V.21 calls (Default Bell 103).

1

2

Enables un-encoded (non-trellis coded)

 

 

modulation in V.32 mode.

2

4

Disables V.32 modulation.

3

8

Disables 2100 Hz answer tone to allow two

 

 

V.42 modems to connect more quickly.

4

16

Enables V.23 fallback mode.

5

32

Disables V.32bis mode.

6

64

Reserved

file:///C/WEBPAGE/guides/rmm/rmm_manl.htm (17 of 21) [2/7/2000 10:55:44 AM]

Image 17
Contents Users Guide Table of ContentsStatus Meaning IntroductionUnit Description Operation BAUD=9600 PARITY=N WORDLEN=8 DIAL=PULSE on Hook InstallationSwitch Factory Function Command Function/Options Command SummaryOriginates call using answer reverse frequencies Pulse Rotary Dial ModeResult Codes Sets result code displayed. The default isRequires @ in dial string replaces no Carrier ConnectControls Carrier Detect CD signal Fixed in ARQ mode, variable in non-ARQ modeSwitch DTR override DTR toggle causes online Command Mode V42BIS/MNP5 data compressionLoads a read-only non-programmable factory configuration Resets on receipt of DTRHz guard tone some European countries requires B0 setting Hz guard tone U.K. requires B0 settingRMM Rack Mount Modem Users Guide Remote Digital with self test and error detector Enables Remote Digital LoopbackAnalog Loopback with self test and error detector Modem controls DSRRegisters Register Default FunctionBit Value Result Disable ARQ/MNP for .22 bis Disable ARQ/MNP forDisable ARQ/MNP for V.32 / V.32bis Disable MNP handshakeOriginates V.21 calls Default Bell Enables ITU-T V.21 modulation at 300 bpsEnables un-encoded non-trellis coded Modulation in V.32 modeEnable V.8 mode Enable V.8 Call IndicateDisable V.34 modulation Disable 33.6 Kbps supportSpecifications Ringer Equivalence 0.9 B Customer ServicePower January Part Number 12548 Revision F