RMM Rack Mount Modem; User's Guide |
|
| ||
|
| 7 | 128 | Software compatibility code. This setting |
|
|
|
| disables the codes and displays the 9600 |
|
|
|
| code instead. The actual rate of the call can |
|
|
|
| be viewed on the ATI6 screen. Used for |
|
|
|
| unusual software incompatibilities. Some |
|
|
|
| software may not accept 7200, 12000 and |
|
|
|
| 14400 bps or greater result codes. |
S28 | 0 | Eliminates the V.32 answer tones for a faster connection. |
| 8 | Default item, all times are in tenths of a second. | ||
| 255 | Disables all connections except V.32 at 9600 bps. | ||
S29 | 20 | Sets the duration (in tenths of a second) of the V.21 answer mode. | ||
S30 | 0 | Reserved |
|
|
S31 | 128 | Reserved |
|
|
S32 | 2 | |||
|
| see the instructions for S13. | ||
|
| Bit | Value | Result |
|
| 0 | 1 | Enable V.8 Call Indicate. |
|
| 1 | 2 | Enable V.8 mode. |
|
| 3 | 8 | Disable V.34 modulation. |
|
| 4 | 16 | Disable 33.6 Kbps support. |
|
| 5 - 7 | 32 - 128 | Reserved |
S33 | 0 | |||
|
| see the instructions for S13. | ||
|
| Bit | Value | Result |
|
| 0 | 1 | Disable 2400 symbol rate. |
|
| 1 | 2 | Disable 2743 symbol rate. |
|
| 2 | 4 | Disable 2800 symbol rate. |
|
| 3 | 8 | Disable 3000 symbol rate. |
|
| 4 | 16 | Disable 3200 symbol rate. |
|
| 5 | 32 | Disable 3429 rate. |
|
| 6 | 64 | Reserved |
|
| 7 | 128 | Disable shaping. |
file:///C/WEBPAGE/guides/rmm/rmm_manl.htm (18 of 21) [2/7/2000 10:55:45 AM]