Western Telematic RMM-288 Enable V.8 Call Indicate, Enable V.8 mode, Disable V.34 modulation

Page 18

RMM Rack Mount Modem; User's Guide

 

 

 

 

7

128

Software compatibility code. This setting

 

 

 

 

disables the codes and displays the 9600

 

 

 

 

code instead. The actual rate of the call can

 

 

 

 

be viewed on the ATI6 screen. Used for

 

 

 

 

unusual software incompatibilities. Some

 

 

 

 

software may not accept 7200, 12000 and

 

 

 

 

14400 bps or greater result codes.

S28

0

Eliminates the V.32 answer tones for a faster connection.

 

8

Default item, all times are in tenths of a second.

 

255

Disables all connections except V.32 at 9600 bps.

S29

20

Sets the duration (in tenths of a second) of the V.21 answer mode.

S30

0

Reserved

 

 

S31

128

Reserved

 

 

S32

2

Bit-mapped register setup for 28.8 modems only. To set the register,

 

 

see the instructions for S13.

 

 

Bit

Value

Result

 

 

0

1

Enable V.8 Call Indicate.

 

 

1

2

Enable V.8 mode.

 

 

3

8

Disable V.34 modulation.

 

 

4

16

Disable 33.6 Kbps support.

 

 

5 - 7

32 - 128

Reserved

S33

0

Bit-mapped register setup for 28.8 modems only. To set the register,

 

 

see the instructions for S13.

 

 

Bit

Value

Result

 

 

0

1

Disable 2400 symbol rate.

 

 

1

2

Disable 2743 symbol rate.

 

 

2

4

Disable 2800 symbol rate.

 

 

3

8

Disable 3000 symbol rate.

 

 

4

16

Disable 3200 symbol rate.

 

 

5

32

Disable 3429 rate.

 

 

6

64

Reserved

 

 

7

128

Disable shaping.

file:///C/WEBPAGE/guides/rmm/rmm_manl.htm (18 of 21) [2/7/2000 10:55:45 AM]

Image 18
Contents Table of Contents Users GuideIntroduction Unit DescriptionStatus Meaning Operation Installation BAUD=9600 PARITY=N WORDLEN=8 DIAL=PULSE on HookSwitch Factory Function Command Summary Command Function/OptionsPulse Rotary Dial Mode Originates call using answer reverse frequenciesSets result code displayed. The default is Result CodesConnect Requires @ in dial string replaces no CarrierSwitch DTR override DTR toggle causes online Command Mode Fixed in ARQ mode, variable in non-ARQ modeControls Carrier Detect CD signal V42BIS/MNP5 data compressionHz guard tone some European countries requires B0 setting Resets on receipt of DTRLoads a read-only non-programmable factory configuration Hz guard tone U.K. requires B0 settingRMM Rack Mount Modem Users Guide Analog Loopback with self test and error detector Enables Remote Digital LoopbackRemote Digital with self test and error detector Modem controls DSRRegister Default Function RegistersBit Value Result Disable ARQ/MNP for V.32 / V.32bis Disable ARQ/MNP forDisable ARQ/MNP for .22 bis Disable MNP handshakeEnables un-encoded non-trellis coded Enables ITU-T V.21 modulation at 300 bpsOriginates V.21 calls Default Bell Modulation in V.32 modeDisable V.34 modulation Enable V.8 Call IndicateEnable V.8 mode Disable 33.6 Kbps supportSpecifications Customer Service PowerRinger Equivalence 0.9 B January Part Number 12548 Revision F