S00=001 S01=000 S02=043 S03=013 S04=010 S05=008 S06=002 S07=060 S08=002 S09=006 S10=007 S11=070 S12=050 S13=000 S14=000 S15=000 S16=000 S17=000 S18=000 S19=000 S20=000 S21=010 S22=017 S23=019 S24=000 S25=005 S26=000 S27=000 S28=008 S29=020 S30=000 S31=000 S32=000 S33=000 S34=006 S35=000 S36=014 S37=000 S38=000 S44=015 S51=000

Figure 2: The Status Screen (Defaults Shown)

4. Installation

4.1. 48 Volt DC Power Option

The 48 Volt DC input is not polarity sensitive. Therefore, you can connect either positive or negative wires from your 48 volt power source to either input and the internal circuitry will adjust for the proper polarity.

Input Range: 40 - 60 Volts DC, 200 milliamps maximum.

Figure 3: 48 Volt DC Power Option

file:///C/WEBPAGE/guides/rmm/rmm_manl.htm (4 of 21) [2/7/2000 10:55:42 AM]

Image 4
Contents Table of Contents Users GuideUnit Description IntroductionStatus Meaning Operation Installation BAUD=9600 PARITY=N WORDLEN=8 DIAL=PULSE on HookSwitch Factory Function Command Summary Command Function/OptionsPulse Rotary Dial Mode Originates call using answer reverse frequenciesSets result code displayed. The default is Result CodesConnect Requires @ in dial string replaces no CarrierFixed in ARQ mode, variable in non-ARQ mode Controls Carrier Detect CD signalSwitch DTR override DTR toggle causes online Command Mode V42BIS/MNP5 data compressionResets on receipt of DTR Loads a read-only non-programmable factory configurationHz guard tone some European countries requires B0 setting Hz guard tone U.K. requires B0 settingRMM Rack Mount Modem Users Guide Enables Remote Digital Loopback Remote Digital with self test and error detectorAnalog Loopback with self test and error detector Modem controls DSRRegister Default Function RegistersBit Value Result Disable ARQ/MNP for Disable ARQ/MNP for .22 bisDisable ARQ/MNP for V.32 / V.32bis Disable MNP handshakeEnables ITU-T V.21 modulation at 300 bps Originates V.21 calls Default BellEnables un-encoded non-trellis coded Modulation in V.32 modeEnable V.8 Call Indicate Enable V.8 modeDisable V.34 modulation Disable 33.6 Kbps supportSpecifications Power Customer ServiceRinger Equivalence 0.9 B January Part Number 12548 Revision F