VXI 82-0102-000, CT-100C Series Six-Slot VXIBus Chassis user manual Input Voltage / Freq

Page 18

VXI Technology, Inc.

POWER SPECIFICATIONS

USEABLE POWER

500 W to 50 °C, derated by 2.5%/ °C above 50 °C

DC SUPPLY VOLTAGE

 

 

Peak

Dynamic

 

 

Induced

 

 

 

Current

Current

 

Ripple/Noise

Ripple

 

 

Voltage

(IMP)

(IMD)

Allowed Variation

DC Load

Noise

 

 

+5 V

40 A

5 A

+0.25 V / -0.125 V

50 mV

50 mV

 

 

-5.2 V

10 A

5 A

-0.26 V / +0.125 V

50 mV

50 mV

 

 

-2 V

8 A

2 A

-0.10 V / +0.72 V

50 mV

50 mV

 

 

+12 V

8 A

2 A

+0.60 V / -0.36 V

50 mV

50 mV

 

 

-12 V

4 A

2 A

-0.60 V / +0.36 V

50 mV

50 mV

 

 

+24 V

4 A

2 A

+1.20 V / -0.72 V

150 mV

150 mV

 

 

-24 V

4 A

2 A

-1.20 V / +0.74 V

150 mV

150 mV

 

 

 

 

 

 

 

 

 

POWER INPUT

 

 

 

 

 

 

 

Input Voltage / Freq.

Minimum 100 V ac to a maximum 240 V ac, 50 Hz/60 Hz

 

 

Nominal AC

 

 

Inrush Current

< 40 A (cold start)

 

 

 

 

 

Input Power

10 A max

 

 

 

 

 

 

Input Leakage

< 1.24 MA @ 264 V ac, 53 Hz

 

 

 

 

Input Harmonics

Meets EN61000-3-2

 

 

 

 

 

Fuse

Internal and independent of line voltage (not user accessible)

 

 

POWER SUPPLIES

 

 

 

 

 

 

 

 

UL, CSA, TUV approved, CE marked

 

 

 

 

Shout circuit, over-voltage, reverse voltage and thermal shutdown protection

 

 

 

 

 

 

 

 

 

COOLING SPECIFICATIONS

 

 

 

 

 

 

 

COOLING REQUIREMENTS*

 

 

 

 

 

 

 

Low Fan Speed

56 W/slot for a 10°C Rise

 

 

 

 

 

84 W/slot for a 15°C Rise

 

 

 

 

High Fan Speed

80 W/slot for a 10°C Rise

 

 

 

 

120 W/slot for a 15°C Rise

*Calculated using VXI-8 Rev. 2.0 standards

COOLING MODES

High or low speed cooling modes can be selected by moving the Fan Speed switch at the rear of the chassis. The power supply and modules are cooled by separate fans.

AIR FLOW PATH

Air is drawn into the chassis from the rear and is pressurized below the cards. The air is then distributed across all slots along the total length of each slot and is exhausted through the top of the mainframe. When the mainframe is rack mounted, allow approximately 2 inches (50 mm) of clearance at the top and rear for proper airflow.

ACOUSTIC NOISE

High Speed Fan Mode < 40 dBA

Low Speed Fan Mode < 30 dBA

18

CT-100C Introduction

Image 18
Contents CT-100C Series VXI Technology, Inc Table of Contents Certification WarrantyLimitation of Warranty Restricted Rights LegendC L a R a T I O N O F C O N F O R M I T Y EMCGeneral Safety Instructions Terms and SymbolsAvoid Electric Shock Support Resources CT-100C Preface Page Introduction IntroductionGeneral Description BackplanePerformance Flexibility 2CT-100CSIX-SLOT Chassis Covers OFFCT-100C Mainframe Features Mainframe Feature LocationsVoltage Monitor Leds Front Panel Voltage MonitorsJ201 Connector PIN Assignments J201 Connector PIN DetailCT-100C Specifications MtbfMttr Input Voltage / Freq Fan atH igh Speed Fan at Low S peed 7CT-100C Dimensional Diagram Installation Remote POWER-ON Option Remote POWER-ON Switch Wiring+5 V Standby Wiring Diagram +5 V Standby UsageFAN Speed Switch FAN Speed Switch LocationRackmount Option Installation OverviewRackmount KIT Installation Parts ListRackmount EAR Installation Diagram Rack Slide Installation 20 Assembly InstructionsRack Slide Installation Diagram Rackmount Door KIT Installation Rack Door Installation Diagram Acrylic Rackmount Door KIT Installation Acrylic Rack Door Installation Diagram Installation of VXI Modules Installation ProcedureDisconnecting the Mainframe VXI Technology, Inc CT-100C Installation Service Information Replicable Parts ListCT-100C Power Supply Replacement Power Supply Replacement Diagram Cleaning the Mainframe Index