RACKMOUNT OPTION INSTALLATION

OVERVIEW

This section contains the procedures for installing a CT-100C chassis in a standard 19” relay rack. The available rackmounting options are:

Option 52 – Rackmount Ear Kit

Option 53 – Rackmount Door Kit

Option 57 – 20” Slide Kit

Option 58 – 24” Slide Kit

The rackmount ear kit provides the basic hardware necessary to rackmount the CT-100C chassis. Because the chassis is only 15” wide, standard rack support rails cannot provide mechanical support to the chassis. If the equipment mounted below the CT-100C cannot provide mechanical support to the chassis, either 20” or 24” slides will be required to support the chassis in the rack. The rackmounting ears are designed to allow the chassis to be flush mounted in the rack or recessed 4”.

The rackmount door kit provides the necessary hardware to install either a 1/8” thick aluminum door or a 1/8” thick acrylic door in front of the rackmounted chassis. These options require that the rackmount ear kit also be installed and configured for recessed mounting. The door may be customer modified to hold connectors, controls, indicators, and similar components.

The 20” and 24” slide kits provide the ability to easily remove the chassis from the rack for servicing and provides mechanical support for the chassis when installed in the rack. The 20” slide kit is used when the chassis is flush mounted in the rack. If the chassis is to be recess mounted, then the 24” slides are required.

CT-100C Installation

25

Image 25
Contents CT-100C Series VXI Technology, Inc Table of Contents Limitation of Warranty WarrantyCertification Restricted Rights LegendEMC C L a R a T I O N O F C O N F O R M I T YTerms and Symbols General Safety InstructionsAvoid Electric Shock Support Resources CT-100C Preface Page Introduction IntroductionBackplane General DescriptionPerformance 2CT-100CSIX-SLOT Chassis Covers OFF FlexibilityMainframe Feature Locations CT-100C Mainframe FeaturesFront Panel Voltage Monitors Voltage Monitor LedsJ201 Connector PIN Detail J201 Connector PIN AssignmentsMtbf CT-100C SpecificationsMttr Input Voltage / Freq Fan atH igh Speed Fan at Low S peed 7CT-100C Dimensional Diagram Installation Remote POWER-ON Switch Wiring Remote POWER-ON Option+5 V Standby Usage +5 V Standby Wiring DiagramFAN Speed Switch Location FAN Speed SwitchOverview Rackmount Option InstallationParts List Rackmount KIT InstallationRackmount EAR Installation Diagram Assembly Instructions Rack Slide Installation 20Rack Slide Installation Diagram Rackmount Door KIT Installation Rack Door Installation Diagram Acrylic Rackmount Door KIT Installation Acrylic Rack Door Installation Diagram Installation Procedure Installation of VXI ModulesDisconnecting the Mainframe VXI Technology, Inc CT-100C Installation Replicable Parts List Service InformationCT-100C Power Supply Replacement Power Supply Replacement Diagram Cleaning the Mainframe Index