RACKMOUNT DOOR KIT INSTALLATION

The rackmount door kit (Option 60) provides the necessary hardware to install a 1/8” thick aluminum door in front of the rackmounted chassis. This option requires that the rackmount ear kit also be installed and configured for recessed mounting. The door may be customer modified to hold connectors, controls, indicators and similar components.

Required Tools

1.#2 Phillips Screwdriver

2.1/8" Flat Blade Screwdriver

3.11/32" Open Ended Wrench

Parts List

QTY

ITEM

VTI P/N

2

Screw, 6-32 x 1/2” Pan Head Ph, Sq Cone Sems Zinc

37-0028-050

2

Nut, Hex, 6-32, Zinc/Steel

37-0030-632

1

Latch, Vise Action, Know Style, Black

37-0065-000

2

Hinge, Adjustable Damping, Black

37-0066-000

8

Screw, 8-32 x 3/8” Pan Head Phil, M/S, Blk Zinc

37-0079-037

4

Screw, 8-32 x 3/8” Flat Head Phillips, Zinc

37-0080-037

1

Latch, Door, Rackmount, CT-100C

41-0133-000

1

Door, Front, Rackmount, CT-100C

41-0134-000

2

Brace, Rackmount, CT-100C

41-0136-000

Assembly Procedure

1.Lay the chassis on a protected work surface on its long side with the voltage monitor LEDs of the chassis facing front with the power switch toward the top.

2.Locate two rackmount (cross) braces. Install one each along the front of the flanges (one on top and one on the bottom) using four (two ea.) #8 flathead screws. The lip along the long edge of each brace goes toward the front and pointing inside. The braces fit over the flanges and the screws are placed from the inside going through the flange and then into the brace.

3.Locate the front door and two hinges. Install the two hinges to the front door using four black screws provided.

4.Locate the latch kit and install it into the door from the side where the hinges are mounted.

5.Locate the door latch bracket and install it on the rackmount ear opposite the end where the hinges will be installed. Use Figure 1-6as a reference.

6.Locate the four tapped holes on the front surface of the rackmount ear to which the door is to be attached.

7.Install the door by its hinges to the rackmount ear using four black screws provided with the option kit.

8.Test that the door opens and closes smoothly and adjust the latch as necessary to secure the door when latched close.

30

CT-100C Installation

Image 30
Contents CT-100C Series VXI Technology, Inc Table of Contents Certification WarrantyLimitation of Warranty Restricted Rights LegendC L a R a T I O N O F C O N F O R M I T Y EMCGeneral Safety Instructions Terms and SymbolsAvoid Electric Shock Support Resources CT-100C Preface Page Introduction IntroductionGeneral Description BackplanePerformance Flexibility 2CT-100CSIX-SLOT Chassis Covers OFFCT-100C Mainframe Features Mainframe Feature LocationsVoltage Monitor Leds Front Panel Voltage MonitorsJ201 Connector PIN Assignments J201 Connector PIN DetailCT-100C Specifications MtbfMttr Input Voltage / Freq Fan atH igh Speed Fan at Low S peed 7CT-100C Dimensional Diagram Installation Remote POWER-ON Option Remote POWER-ON Switch Wiring+5 V Standby Wiring Diagram +5 V Standby UsageFAN Speed Switch FAN Speed Switch LocationRackmount Option Installation OverviewRackmount KIT Installation Parts ListRackmount EAR Installation Diagram Rack Slide Installation 20 Assembly InstructionsRack Slide Installation Diagram Rackmount Door KIT Installation Rack Door Installation Diagram Acrylic Rackmount Door KIT Installation Acrylic Rack Door Installation Diagram Installation of VXI Modules Installation ProcedureDisconnecting the Mainframe VXI Technology, Inc CT-100C Installation Service Information Replicable Parts ListCT-100C Power Supply Replacement Power Supply Replacement Diagram Cleaning the Mainframe Index