VXI 82-0102-000, CT-100C Series Six-Slot VXIBus Chassis Rackmount KIT Installation, Parts List

Page 26

VXI Technology, Inc.

RACKMOUNT KIT INSTALLATION

The rackmount kit (Option 59) provides the basic hardware necessary to rack mount the CT-100C chassis. With the chassis being only 15” wide, standard rack support rails cannot provide mechanical support to the chassis. If the equipment mounted below the CT-100C cannot provide mechanical support to the chassis, either 20” or 24” rack slides will be required to support the chassis when installed into the rack. The rackmounting ears are designed to allow the chassis to be flush mounted in the rack or recessed 4”.

Required Tools

1.#2 Phillips Screwdriver

Parts List

QTY

ITEM

VTI P/N

4

Screw, 6-32 x 1/2", Phillips/Sems

37-0028-050

1

Bracket, Rack Flange w/ hinge mounting holes

41-0135-000

1

Bracket, Rack Flange

41-0135-001

Assembly Procedure

1.Remove the four (4) black plastic feet from the bottom of the chassis.

2.Lay the chassis on a protected work surface on its long side with the voltage monitor LEDs of the chassis facing front with the power switch toward the top.

3.Locate and remove four black plastic feet on the side of the chassis and four black plastic feet on the bottom of the chassis. Retain the feet if restoring the chassis to its original portable use is anticipated.

4.Find two threaded holes on each side of the chassis (the plastic feet were attached to two of these holes) towards the front of the unit.

5.Line up the rackmount ears with the threaded holes selecting the flush or recessed position as desired. Refer to the rackmount ear Figure 1-4for visual assistance.

6.Secure the rack ears using the supplied #8-32 hardware.

Before installing the chassis into an EIA switch rack, the chassis handle should be removed. This can be done by doing the following:

1.Remove the four screws located near the handle.

2.Remove the two black decorative covers at each end of the carrying handle using the flat blade screwdriver. Place a piece of paper under the screwdriver blade to prevent scratching the chassis cover.

3.Remove the four Phillips screws holding the handle in place and then remove the handle itself. Retain the carrying handle components if there may be some need to restore the chassis to its original portable use in the future.

26

CT-100C Installation

Image 26
Contents CT-100C Series VXI Technology, Inc Table of Contents Certification WarrantyLimitation of Warranty Restricted Rights LegendC L a R a T I O N O F C O N F O R M I T Y EMCGeneral Safety Instructions Terms and SymbolsAvoid Electric Shock Support Resources CT-100C Preface Page Introduction IntroductionPerformance General DescriptionBackplane Flexibility 2CT-100CSIX-SLOT Chassis Covers OFFCT-100C Mainframe Features Mainframe Feature LocationsVoltage Monitor Leds Front Panel Voltage MonitorsJ201 Connector PIN Assignments J201 Connector PIN DetailMttr CT-100C SpecificationsMtbf Input Voltage / Freq Fan atH igh Speed Fan at Low S peed 7CT-100C Dimensional Diagram Installation Remote POWER-ON Option Remote POWER-ON Switch Wiring+5 V Standby Wiring Diagram +5 V Standby UsageFAN Speed Switch FAN Speed Switch LocationRackmount Option Installation OverviewRackmount KIT Installation Parts ListRackmount EAR Installation Diagram Rack Slide Installation 20 Assembly InstructionsRack Slide Installation Diagram Rackmount Door KIT Installation Rack Door Installation Diagram Acrylic Rackmount Door KIT Installation Acrylic Rack Door Installation Diagram Installation of VXI Modules Installation ProcedureDisconnecting the Mainframe VXI Technology, Inc CT-100C Installation Service Information Replicable Parts ListCT-100C Power Supply Replacement Power Supply Replacement Diagram Cleaning the Mainframe Index