Vantec UGT-ST310R user manual Rebuilding a Failed Mirror Set, RAID 0+1 Mirroring + Striping

Page 9

9.Input the RAID size, press Enter.

10.Press Ctrl+E to exit the BIOS.

11.When asked Are you sure to exit(Y/N)?, press Y to exit and reboot.

Note: If during boot the RAID BIOS reports an RAID1 set is in

Rebuild status, The rebuild will continue after boot sequence is complete, disregard the message, continue

booting, and let the Mirror rebuild.

Rebuilding a Failed Mirror Set

When a failure to one member occurs, you will be notified either by the RAID BIOS during boot or by the SATARAID5 GUI while in Windows. The steps below will guide you in rebuilding a failed mirror set.

1.Replace the failed drive with one of equal or greater capacity, then start the computer.

2.During boot press Ctrl+S or F4 to enter the RAID BIOS.

3.Select Create RAID Set then press Enter.

4.Select SPARE DRIVE then press Enter.

5.Select the replacement drive then press Enter.

6.When asked Are You Sure(Y/N)?, press Y to confirm.

7.Press Ctrl+E to exit.

8.When asked Are you sure to exit(Y/N)?, press Y to exit.

RAID 0+1 (Mirroring + Striping)

This RAID array to be used on New/Blank hard drives, do not

UGT-ST310R

Page 9

Image 9
Contents Port Sata II 150 PCI Host Card w/RAID Table of Contents Connectors Package ContentsBus Interface Hardware Description System RequirementsDevice Connection Hardware InstallationSize, Manual Configuration is offered Auto configuration recommendedConfiguration RAID ArraysManual configuration Select Auto configuration, then press EnterSelect Manual configuration then press Enter RAID 1 Mirror For New/Blank Hard Drives Select Manual configuration, then press EnterFor Existing Hard Drives with Data Select Create with data copy, then press EnterRebuilding a Failed Mirror Set When asked Are you sure to exitY/N?, press Y to exitRAID 0+1 Mirroring + Striping Select Create RAID Set then press EnterAuto configuration recommended RAID 5 Parity EnterSelect Create without data copy then press Enter When asked Are you sure to exitY/N?, press Y to exit Deleting RAID Arrays Concatenation JbodResolving Conflicts Low Level FormatLogical Drive Info Bios Configuration Driver InstallationFor Windows For Windows XP/Server For Windows XP-x64/Server For Windows Vista For Windows Vista-x64 To Verify Windows InstallationSata RAID 5 Management Software Installation For Windows 2000/XP/Server 2003/VistaFor Windows XP-x64/Server 2003-x64/Vista-x64