Perle Systems DS1, TS2 manual Add Custom-IPv6, Set Custom-IPv6

Page 23

 

IPv6 Commands

 

 

Add Custom-IPv6

 

Description

Adds a custom IPv6 address to the IOLAN. You can specify either a complete IPv6

User Level

address or an IPv6 network address.

Admin

Syntax

add custom-ipv6 method auto network-prefix <network_prefix>

 

[prefix-bits <0-64>]

 

add custom-ipv6 method manual ipv6-address <ipv6_address>

 

[prefix-bits <0-128>]

Options

method auto

 

When this option is specified, the IOLAN will derive an IPv6 address from the entered

 

network prefix and the IOLAN’s MAC address. This is the default option.

 

network-prefix

 

Specify the IPv6 network prefix. The IOLAN will derive the complete IPv6 address

 

from the entered network prefix and the IOLAN’s MAC address.

 

prefix-bits (auto)

 

Specify the network prefix bits for the IPv6 address.

 

Range: 0-64

 

Default: 64

 

method manual

 

Specify this option when you want to enter a specific IPv6 address.

 

ipv6-address

 

Specify the complete IPv6 address.

 

Field Format: IPv6 address

 

prefix-bits (manual)

 

Specify the network prefix bits for the IPv6 address.

 

Range: 0-128

 

Default: 64

Set Custom-IPv6

 

Description

Configures custom IPv6 network and IP addresses.

User Level

Admin

Syntax

set custom-ipv6 <config_ipv6_address> method auto

 

network-prefix <network_prefix> [prefix-bits <0-64>]

 

set custom-ipv6 <config_ipv6_address> method manual

 

ipv6-address <ipv6_address> [prefix-bits <0-128>]

Options

method auto

 

When this option is specified, the IOLAN will derive an IPv6 address from the entered

 

network prefix and the IOLAN’s MAC address. This is the default option.

 

network-prefix

 

Specify the IPv6 network prefix. The IOLAN will derive the complete IPv6 address

 

from the entered network prefix and the IOLAN’s MAC address.

24

Image 23
Contents Iolan DS1/TS2 EN 55022 1998, Class A, Note Table of Contents User Commands Line Commands Network Commands Time Commands Statistic Commands Set IOChannel Digital Output Serial Pins Intended Audience PrefaceAbout This Book Making a Technical Support Query Contacting Technical SupportFeedback on this Manual Repair ProcedureCLI Conventions Command SyntaxIntroduction IntroductionCommand Options Command ShortcutsSet Server Server CommandsServer Commands Set Custom-AppDefault Interval 180 seconds. monitor-connection-timeout Bypass-passwordDhcp/bootp Default size 1500 bytes DomainnameDefault Buffer Size 4 KB TS1 Oem-loginPassword-limit TimeoutShow Server Set ServiceShow Custom-App Show ModbusOptions Auto10-half10-full100-half100-full Hardware CommandsSet Ethernet Show HardwareSet Modbus Gateway Modbus CommandsShow TruePort TruePort Baud CommandsSet TruePort Remap-Baud Show IPv6 IPv6 CommandsSet IPv6 Set Custom-IPv6 Add Custom-IPv6Field Format IPv6 address prefix-bits manual Range Default 64 method manualRange Default Delete Custom-IPv6Commands for Users Logged Into the Iolan User CommandsScreen MenuPing ResumeSet User Session Set UserShow Termtype Show Line UsersSyslog Console Show SessionsTcpport TelnetAdd User Configuring UsersSet Default User VersionLevel Hotkey-prefixPhone-number Line-accessService Sess-timerPassword Show User Show Default UserConfigureduser Set Line Line CommandsPort vs -Port Line Commands Line CommandsBreak-length Break-delayDial-timeout Options breakFlowout Default Buffer Size 4 KB DS1/TS1/STS8DDefault Disabled initial FlowinLine-name ResetInternet-address KeepaliveStop-bits Default Disabled Session stringsDefault 10 ms Sess-timer Send-nameSet Line Interface Confighost Set Line ServiceHostport ServerportInitstring Set ModemModemname Show Line Line Service CommandsOptions Program-command-line Options termtype Set Telnet-ClientEndipaddress Set UDPOutboundport StartipaddressSet Vmodem Set Vmodem-Phone Host Set Modbus-Slave LineSet Modbus-Master Line IpaddressSet Line Initiate-Connection Set Multihost LineShow Vmodem Show InterfaceShow Telnet-Client Show UDPShow Modems Modem CommandsAdd Modem Delete ModemSet Packet-Forwarding Line Packet Forwarding CommandsEnable-end-eof2 Enable-end-trigger1Enable-end-trigger2 Enable-end-eof1Show Packet-Forwarding Line Add Trap Network Commands ChapterSnmp Commands Add CommunitySet Snmp Delete CommunityDelete Trap Show Snmp Set Snmp inform-timeoutSet Snmp engine-id-string Set Snmp inform-retriesHosts Commands Tftp CommandsDelete Gateway Gateway CommandsShow Hosts Add GatewayDestinationip Description Configures the gateway User Level Admin SyntaxSet Gateway Show GatewaysShow Syslog Logging CommandsSet Syslog Time/Date Setting Commands Time CommandsTime Commands Show Date Bootup Commands Administration CommandsSet cli Set BootupShow Bootup Show ARPFilename Tftp File Transfer CommandsNetload Hostname/ipaddressTable or a DNS server Custom Factory DefaultOptions Factory-default-config NetsaveShow Motd Motd CommandsSet Set MotdShow Modbus Statistics Statistic Commands ChapterConfiguration Statistics Show NetstatRun-Time Statistics Set IO UDP O CommandsGlobal I/O Commands Set IO Modbus Set IO Temperature-ScaleSet Line Set IO FailsafeSet IOChannel Digital Input Set IOChannel ModeSet IOChannel Set IOChannel Digital I/OSet IOChannel Digital Input Serial Pins Will be displayed as active Current status. The default is disabledSet IOChannel Digital Output Description can be up to 20 charactersInactive-to-active-delay Active-signal-widthInactive-signal-width Active-to-inactive-delayRelaynumber Set IOChannel Digital Output Serial PinsSet IOChannel Relay Options descriptionOptions analogchannel Set IOChannel Analog True AnalogClear-level Trigger-typeTrigger-level Clear-modeSet IOChannel Analog Temperature Level Options channel EnabledDefault Disabled keepalive Set IOChannel IOExtensionLocal-connection inputchannel Client-initiated tcp-portClient-initiated multihost Server-initiated tcp-portChannel Set IOChannel MultihostShow IOChannel Status Kill IOChannelShow IOChannel Show IORelay Channel Control CommandsDigital Output Digital InputGlossary
Related manuals
Manual 246 pages 24.21 Kb Manual 224 pages 30.96 Kb Manual 122 pages 55.83 Kb

DS1, TS2 specifications

Perle Systems TS2 and DS1 are advanced serial-to-Ethernet devices designed to facilitate seamless integration of serial devices with modern IP networks. These devices serve as crucial tools for businesses looking to enhance their communication capabilities while leveraging existing infrastructure.

One of the standout features of the Perle TS2 and DS1 is their ability to support multiple serial protocols including RS232, RS422, and RS485. This versatile support allows businesses to connect various legacy devices to their networks, ensuring that critical equipment can still communicate effectively in an increasingly digital landscape.

The TS2 model is particularly noted for its dual serial ports, enabling simultaneous communication with multiple devices. This capability is invaluable for applications requiring real-time data transmission, such as remote monitoring and automated control systems. The DS1 model, on the other hand, is designed for single-port use, making it an ideal solution for smaller-scale operations or specific single-device connections.

Both the TS2 and DS1 incorporate advanced features such as configuration through a web interface, which simplifies setup and management. Users can easily access device settings and monitor performance metrics remotely, enhancing operational efficiency. These devices also support various network protocols such as TCP/IP, UDP, and ICMP, ensuring compatibility with a wide range of network architectures.

In terms of security, Perle Systems prioritize user data protection. The TS2 and DS1 offer features including SSL encryption and SSH protection, providing an added layer of security for sensitive information transmitted over the network. This is particularly important for industries where data integrity and security are paramount, such as healthcare and finance.

Additionally, the rugged design of both devices ensures reliable performance even in harsh environments. With extended temperature ratings and robust housing, the TS2 and DS1 can operate in diverse conditions without compromising functionality.

To summarize, the Perle Systems TS2 and DS1 provide a reliable and flexible solution for connecting legacy serial devices to modern networks. With their support for multiple serial protocols, web-based management, robust security features, and rugged design, these devices cater to a variety of industries looking to modernize their communication infrastructure while maintaining existing equipment. Whether for large-scale operations or smaller implementations, the TS2 and DS1 equip businesses with the tools needed for effective serial communication in an IP-driven world.