Perle Systems DS1, TS2 manual Delete Community, Delete Trap, Set Snmp

Page 57

SNMP Commands

 

<config_host><ip_address>

 

Defines the hosts (by IPv4 or IPv6 address) that will receive trap messages generated by

 

the IOLAN. Up to four trap hosts can be defined.

 

<version>

 

Select the version of trap you want the IOLAN to send. Valid options are v1, v2c or v3.

 

<type>

 

Select between trap or inform. Inform requires the receiving host to acknowledge

 

receipt of the trap.

Delete Community

 

Description

Deletes an SNMP community (version 1 and version 2).

User Level

Admin

Syntax

delete community <config_community_number>

Option

<config_community_number>

 

When you add an SNMP community, it gets assigned to a number. To delete the SNMP

 

community, you need to specify the number of the community that you want to delete.

 

To see which community is assigned to what number, type the show snmp command.

Delete Trap

 

Description

Deletes an SNMP trap host.

User Level

Admin

Syntax

delete trap <config_trap_number>

Option

<config_trap_number>

 

When you add an SNMP trap host, it gets assigned to a number. To delete the SNMP

 

trap host, you need to specify the number of the trap that you want to delete. To see

 

which trap host is assigned to what number, type the show snmp command.

Set SNMP

 

Description

Configures SNMP settings.

User Level

Admin

Syntax

set snmp [contact <string>] [location <string>]

 

[readonly user <username>] [readwrite user <username>][trap user

 

<username>]

Options

contact

 

The name and contract information of the person who manages this SMNP node.

 

location

 

The physical location of the SNMP node.

 

readonly user

 

Specifies the name of the read only user.

 

readwrite user

 

Specifies the name of the read/write user.

 

trap user

 

Specify the name of the trap user.

58

Image 57
Contents Iolan DS1/TS2 EN 55022 1998, Class A, Note Table of Contents User Commands Line Commands Network Commands Time Commands Statistic Commands Set IOChannel Digital Output Serial Pins Preface About This BookIntended Audience Making a Technical Support Query Contacting Technical SupportFeedback on this Manual Repair ProcedureIntroduction Command SyntaxIntroduction CLI ConventionsCommand Options Command ShortcutsServer Commands Server CommandsSet Custom-App Set ServerDhcp/bootp Bypass-passwordDefault size 1500 bytes Domainname Default Interval 180 seconds. monitor-connection-timeoutPassword-limit Oem-loginTimeout Default Buffer Size 4 KB TS1Show Custom-App Set ServiceShow Modbus Show ServerSet Ethernet Hardware CommandsShow Hardware Options Auto10-half10-full100-half100-fullSet Modbus Gateway Modbus CommandsTruePort Baud Commands Set TruePort Remap-BaudShow TruePort IPv6 Commands Set IPv6Show IPv6 Set Custom-IPv6 Add Custom-IPv6Range Default Range Default 64 method manualDelete Custom-IPv6 Field Format IPv6 address prefix-bits manualCommands for Users Logged Into the Iolan User CommandsPing MenuResume ScreenSet User Session Set UserSyslog Console Show Line UsersShow Sessions Show TermtypeTcpport TelnetSet Default User Configuring UsersVersion Add UserLevel Hotkey-prefixService Line-accessSess-timer Phone-numberPassword Show Default User ConfigureduserShow User Port vs -Port Line Commands Line CommandsLine Commands Set LineDial-timeout Break-delayOptions break Break-lengthDefault Disabled initial Default Buffer Size 4 KB DS1/TS1/STS8DFlowin FlowoutInternet-address ResetKeepalive Line-nameDefault 10 ms Sess-timer Default Disabled Session stringsSend-name Stop-bitsSet Line Interface Confighost Set Line ServiceHostport ServerportSet Modem ModemnameInitstring Line Service Commands Options Program-command-lineShow Line Options termtype Set Telnet-ClientOutboundport Set UDPStartipaddress EndipaddressSet Vmodem Set Vmodem-Phone Set Modbus-Master Line Set Modbus-Slave LineIpaddress HostSet Line Initiate-Connection Set Multihost LineShow Telnet-Client Show InterfaceShow UDP Show VmodemAdd Modem Modem CommandsDelete Modem Show ModemsSet Packet-Forwarding Line Packet Forwarding CommandsEnable-end-trigger2 Enable-end-trigger1Enable-end-eof1 Enable-end-eof2Show Packet-Forwarding Line Snmp Commands Network Commands ChapterAdd Community Add TrapDelete Community Delete TrapSet Snmp Set Snmp engine-id-string Set Snmp inform-timeoutSet Snmp inform-retries Show SnmpHosts Commands Tftp CommandsShow Hosts Gateway CommandsAdd Gateway Delete GatewaySet Gateway Description Configures the gateway User Level Admin SyntaxShow Gateways DestinationipLogging Commands Set SyslogShow Syslog Time Commands Time CommandsTime/Date Setting Commands Show Date Bootup Commands Administration CommandsShow Bootup Set BootupShow ARP Set cliNetload Tftp File Transfer CommandsHostname/ipaddress FilenameOptions Factory-default-config Custom Factory DefaultNetsave Table or a DNS serverSet Motd CommandsSet Motd Show MotdConfiguration Statistics Statistic Commands ChapterShow Netstat Show Modbus StatisticsRun-Time Statistics O Commands Global I/O CommandsSet IO UDP Set Line Set IO Temperature-ScaleSet IO Failsafe Set IO ModbusSet IOChannel Set IOChannel ModeSet IOChannel Digital I/O Set IOChannel Digital InputSet IOChannel Digital Input Serial Pins Set IOChannel Digital Output Current status. The default is disabledDescription can be up to 20 characters Will be displayed as activeInactive-signal-width Active-signal-widthActive-to-inactive-delay Inactive-to-active-delaySet IOChannel Relay Set IOChannel Digital Output Serial PinsOptions description RelaynumberOptions analogchannel Set IOChannel Analog True AnalogTrigger-level Trigger-typeClear-mode Clear-levelSet IOChannel Analog Temperature Level Default Disabled keepalive EnabledSet IOChannel IOExtension Options channelClient-initiated multihost Client-initiated tcp-portServer-initiated tcp-port Local-connection inputchannelShow IOChannel Status Set IOChannel MultihostKill IOChannel ChannelShow IOChannel Show IODigital Output Channel Control CommandsDigital Input RelayGlossary
Related manuals
Manual 246 pages 24.21 Kb Manual 224 pages 30.96 Kb Manual 122 pages 55.83 Kb

DS1, TS2 specifications

Perle Systems TS2 and DS1 are advanced serial-to-Ethernet devices designed to facilitate seamless integration of serial devices with modern IP networks. These devices serve as crucial tools for businesses looking to enhance their communication capabilities while leveraging existing infrastructure.

One of the standout features of the Perle TS2 and DS1 is their ability to support multiple serial protocols including RS232, RS422, and RS485. This versatile support allows businesses to connect various legacy devices to their networks, ensuring that critical equipment can still communicate effectively in an increasingly digital landscape.

The TS2 model is particularly noted for its dual serial ports, enabling simultaneous communication with multiple devices. This capability is invaluable for applications requiring real-time data transmission, such as remote monitoring and automated control systems. The DS1 model, on the other hand, is designed for single-port use, making it an ideal solution for smaller-scale operations or specific single-device connections.

Both the TS2 and DS1 incorporate advanced features such as configuration through a web interface, which simplifies setup and management. Users can easily access device settings and monitor performance metrics remotely, enhancing operational efficiency. These devices also support various network protocols such as TCP/IP, UDP, and ICMP, ensuring compatibility with a wide range of network architectures.

In terms of security, Perle Systems prioritize user data protection. The TS2 and DS1 offer features including SSL encryption and SSH protection, providing an added layer of security for sensitive information transmitted over the network. This is particularly important for industries where data integrity and security are paramount, such as healthcare and finance.

Additionally, the rugged design of both devices ensures reliable performance even in harsh environments. With extended temperature ratings and robust housing, the TS2 and DS1 can operate in diverse conditions without compromising functionality.

To summarize, the Perle Systems TS2 and DS1 provide a reliable and flexible solution for connecting legacy serial devices to modern networks. With their support for multiple serial protocols, web-based management, robust security features, and rugged design, these devices cater to a variety of industries looking to modernize their communication infrastructure while maintaining existing equipment. Whether for large-scale operations or smaller implementations, the TS2 and DS1 equip businesses with the tools needed for effective serial communication in an IP-driven world.