Timer Limits:

Displaying:

To display timer limits, first push the TIME key. While still in this mode go on to push LIMITS key. The display will briefly show TR1 LT (for timer 1 Limit) and then the previously programmed value. Pushing the LIMITS key one more time will display TR2 LT followed by pre-programmed timer 2 value.

Programming of timer limit values is done during setup procedure (for details look under SETUP). Timer values are can also be displayed without pushing ‘TIME’ key. TR1 LT and TR2 LT is displayed following Process limit 4 (or deviation limit) value, as described above under Process Limits.

Resetting:

The two timer outputs will reset as soon as the time is reset to zero. Time is reset to zero by pushing TIME and RESET keys simultaneously.

ALARM OUTPUTS

Status:

The system has optional process and timer alarm outputs that are activated when the limit is achieved on each one of them. The alarms can be programmed as normally open or normally closed (see SETUP). The status of these is indicated on the front panel by the LEDs. When ever an alarm is activated the respective LED is turned on.

Electro-Mechanical Relay Option:

DP3600 units can be ordered with either open collector outputs or electro-mechanical relays. (Check model number printed on the unit for option). If ordered with relays, then these relays are programmed during Setup to operate as either Normally Open (NO) or Normally Closed (NC). The default setting is Normally Open. Each of these limit relays provides a switched output whenever a limit is reached. The maximum rating for a 120Vac unit is 120Vac @ 0.5 amp or 28 Vdc @ 1.0 amp.

Figure 1. Electro-mechanical Relays Hookup Example

Instrument

 

 

OUTPUT CONNECTOR

 

 

 

 

8

 

Switched Output

LIMIT # 4

 

7

 

120 VAC @ 0.5 AMPS

 

6

 

 

 

Switched Output

LIMIT # 3

 

5

 

120 VAC @ 0.5 AMPS

 

4

 

 

 

Switched Output

LIMIT # 2

 

3

 

120 VAC @ 0.5 AMPS

 

2

 

LIMIT # 1

 

Switched Output

 

1

 

120 VAC @ 0.5 AMPS

 

 

 

LIMIT RELAYS

 

 

 

14

Image 15
Contents Programmable Process Monitors SET UP Flow Chart MAX. and MIN. Readings Peaks Scaling Offset Tare Limits External Hold SpecificationsDescription SET UPSetup Entry Setup ExitHigh Scale ScalingProgramming Group Selection Decimal pointProgram Limits Relay Deadband Timers 1Configuring Limits Normally open/Normally Closed Selection of Limit 4 as Process or Deviation LimitProgram System Input Range Rate Time-BaseRemote Tare/Hold Input TypeSET UP Flow Chart Time ResettingMAX. and MIN. Readings Peaks RateOffset Process ChangeTare LimitsProcess Limits Electro-Mechanical Relay Option Alarm OutputsTimer Limits StatusOpen Collector Option PowerHold Function Saving ParameterPIN no Description Output Connector PIN AssignmentTrouble Shooting Factory default settings for voltage, current and millivoltError Messages Mounting Panel Cutout Dimensions

DP3600 specifications

Omega Engineering has long been a trusted name in the realm of industrial instrumentation, and their DP3600 series has set a high standard in differential pressure measurement. The DP3600 is celebrated for its robustness and versatility, making it a reliable choice for a variety of applications across industries such as HVAC, water treatment, and chemical processing.

One of the standout features of the DP3600 is its advanced microprocessor-based technology. This enables highly accurate measurements and ensures that the device can effectively manage multiple pressure inputs. The DP3600 operates on a wide measurement range, accommodating both high and low differential pressure readings with exceptional precision. It is designed to handle pressures from -500 to +500 inHg, making it suitable for even the most demanding environments.

The device is characterized by its user-friendly interface, which includes a clear digital display that shows real-time readings. This feature not only enhances usability but also ensures that operators can quickly interpret data without extensive training. Furthermore, the DP3600 offers a variety of output options including analog and digital signals, allowing for seamless integration with existing systems.

Durability is another key characteristic of the DP3600. Constructed to endure harsh conditions, it boasts an IP65 rating for dust and water resistance, making it suitable for use in outdoor and high-moisture environments. The unit is also designed for easy installation and maintenance, which helps reduce downtime and operational costs.

Moreover, the DP3600 series includes built-in safety features, such as over-range protection, ensuring that the device remains operational even in extreme conditions. With options for various materials and configurations, users can customize the DP3600 to better fit their application's requirements.

In summary, the Omega Engineering DP3600 series is an advanced differential pressure device that excels in accuracy, versatility, and durability. Its microprocessor-driven capabilities, broad measurement range, and user-friendly interface make it a valuable tool for professionals seeking reliable pressure measurement solutions in challenging environments. With these features, the DP3600 continues to be a preferred choice for industries requiring precise monitoring and control of differential pressure.