How to use the terminals of the ALARM connector
These terminals are used to connect the alarm devices, such as sensors, door switches, etc. |
| ||
The connector to be used should be compatible with the pin array. |
| ||
|
| 13 | 1 |
Pin array |
|
| |
The pin array is different from other digital disk recorders. Make sure |
| ||
that the connection is correct referring to the following. | Alarm | ||
|
|
| |
|
| 25 | 14 |
Pin No. | Signal | Operation | Remarks |
1 | Alarm input 1 | Event actions will be performed according to the | |
2 | Alarm input 2 | settings. | input/5 V |
3Alarm input 3
4Alarm input 4
5Alarm input 5
6Alarm input 6
7Alarm input 7
8Alarm input 8
9 | Alarm output 1 | Alarm signal will be supplied at an event occur- | Open collector output |
|
| rence | 24 V DC max., |
10 | Alarm output 2 |
11Alarm output 3
12Alarm output 4
13Signal ground
14Signal ground
15 | Alarm input 9 | Event actions will be performed according to the | |
|
| settings. | input/5 V |
16 | Alarm input 10 |
17Alarm input 11
18Alarm input 12
19Alarm input 13
20Alarm input 14
21Alarm input 15
22Alarm input 16
23 | Alarm output 5 | Alarm signal will be supplied at an event occur- | Open collector output |
|
| rence | 24 V DC max., |
24 | Alarm output 6 | ||
|
|
|
|
25 | Alarm output 7 |
|
|
|
|
|
|