Assign a program after setting the time zone [Time table]
Select the [Time table] tab on the "Schedule" page. (☞ Page 60)
A time table for program actions can be created for each day of the week, and programs can be assigned to each time table. Up to 6 time tables can be created for each day of the week.
When a signal is supplied from the ALARM/CONTROL connector (external recording changeover, pin no. 24), the recorder will work with the set timetable for "Ext." regardless of the days of the week.
At the default, 0:00 to 24:00, PROG1 has been set for "Daily".
Step 1
Select the desired day of the week.
→The time table of the selected day of the week will be displayed.
Step 2
Configure each setting item.
There are 2 setup pages. To move to another page, select the [k] or [l] button.
[Copy the other program]
To copy a time table set for another day of the week, select the day of the week to be copied, and select the [Copy] but- ton.
■New time table setup
Configure the settings of the following item for each time zone.
[Start]
Set the start time of the time zone.
[End]
Set the end time of the time zone.
Note:
•The time can be set in
However, the end time should be at least 15 minutes later than the start time.
•It is impossible to set "23:46" or later for the start time.
•Set "Start" and "End" in the
[Program]
Select the desired program (PROG1 to 4).
[Event]
Select "On" or "Off" to determine whether or not to perform event actions at an event occurrence.
[Alarm message]
Select "On" or "Off" to determine whether or not to display the
[FTP image transmission by alarm]
Select "On" or "Off" to determine whether or not to transmit the alarm image to the FTP server according to the settings of "Image transmission by alarm" (☞ page 96) on the "Server" page - the [FTP] tab.
81