[Unit address (system)]

Configure the settings relating to PS·Data [PS·Data setup]

Select the [PS·Data setup] tab on the "Communication" page. (Page 60)

The settings for PS·Data can be configured on this tab.

[Unit address (system)]

A unit address is a unique number to be assigned to each PS·Data compatible device. Each address of the system devices must be unique to identify them when connecting two or more PS·Data compatible devices.

For example, numbers "001" - "099" are assigned to unit addresses for system devices.

[Unit address (controller)]

The unit address (controller) is used to control a PS·Data device connected to this unit. Assign a number from "001" - "099" for a unit address.

[Baud rate]

Select a communication speed for data transmission with a connected device from the following:

2 400/4 800/9 600/19 200/38 400 (bps) Default: 9 600

[Data bit]

The data length for communication will be displayed. It is impossible to change the setting value.

[Parity]

Methods of error check for a transmission at communication will be displayed.

It is impossible to change the setting value.

[Stop bit]

Stop bit types will be displayed.

It is impossible to change the setting value.

[Retry timing]

When data reception is not confirmed, the interval to retrans- mit the same data is displayed.

It is impossible to change the setting value.

[Alarm data]

The method to notify the connected controller of an event occurrence is displayed.

It is impossible to change the setting value.

[Camera number setup]

Configure the settings for each camera channel to control cameras using the PS·Data compatible controller.

When the [Setup] button is selected, the following page will be displayed.

[No.]

Select the desired camera number (1 to 999) for each camera channel.

[Back] button

Closes the setup page and returns to the [PS.Data Setup] tab.