![Connection of the control output](/images/new-backgrounds/11621/1162193x1.webp)
Connection of the control output
When an alarm device such as a buzzer or a lamp is connected, the signal output from pin nos.15 - 18 can be used to notify the status by sounding a buzzer or lighting a lamp.
The following example is of a connection with the HDD error output (pin no. 16).
(Signal ground)
| (HDD error output) | |
13 | 16 | Alarming device |
|
|
| Relays, etc.* |
ALARM/CONTROL | * Attached when necessary |
|
Connection with the Uninterruptible Power System (UPS)
This is an example of a connection with the uninterruptible power system (UPS) to be installed to protect from a power outage. When a signal is supplied to the outage detection input terminals from the uninterruptible power system (UPS), internal process- ing (stops recording safely) will start to shut off the power supply for the recorder.
After completing the internal processing, a signal will be supplied from the outage processing end output terminal to the uninter- ruptible power system (UPS). Then, the power supply to the recorder can be suspended.
(Signal ground) | (Signal ground) |
(Outage detection input) | (Detection) |
(Outage processing end output) | (Shutdown) |
Recorder |
|
*Refer to the operating instructions of the UPS in use for how to connect the UPS.
13 | 23 | 19 |
Power cord
ALARM/CONTROL
Uninterruptible
Power System
(UPS)
To electric outlet
Important:
•Be sure to use an UPS that provides a sine wave output.
Do not use an UPS that provides a square wave. It may damage the recorder.