Panasonic WJ-HD616K Connection for emergency recording, Signal ground Emergency recording input

Models: WJ-HD616K WJ-HD716K

1 156
Download 156 pages 35.47 Kb
Page 45
Image 45
Connection for emergency recording

Connection for emergency recording

When the external switch is turned on, emergency recording will start.

Emergency recording will differently be performed depending on the settings on the [Emergency rec.] tab under the "Basic" page of the setup menu. (Page 70)

(Signal ground)

(Emergency recording input)

13 12

External switch

ALARM/CONTROL

Connection for external recording mode changeover

When the external switch is set to "On", recording will start after changing the recording program.

The recording program can be set on "Time table setup(Ext.)" on the [Time table] tab under the "Schedule" page of the setup menu (Page 81).

(Signal ground)

(External recording mode changeover)

13 24

External switch

ALARM/CONTROL

Connection for synchronization of the sequence switchover

Camera channel of the sequence display will be switched upon the signal input to the sequence switchover input. When using multiple recorders, it is possible to synchronize the switchover timing.

The setting for the sequence switchover timing can be configured on "Sequence timing" on the [Monitor 1] tab (or "Monitor 2" tab) under the "Display" page of the setup menu (Pages 86 and 88).

When synchronizing the sequence switchover timing between multiple recorders, the setting for the sequence switchover timing is differently configured between the master recorder and the slave recorder as follows.

Master recorder: Set to "Int" (functions as the output terminal)

Slave recorder: Set to "Ext" (functions as the input terminal)

(Signal ground)

(Signal ground)

 

 

 

(Sequence switchover output)

(Sequence switchover input)

13

21

 

13

21

 

ALARM/CONTROL

 

 

ALARM/CONTROL

 

WJ-HD616K (First)

 

 

WJ-HD616K (Second)

45

Page 45
Image 45
Panasonic WJ-HD616K Connection for emergency recording, Connection for external recording mode changeover, Signal ground