User/Host management
It is necessary to register users who operates the recorder and hosts (PC) that accesses the recorder via a network such as a LAN. Up to 32 users and up to 8 hosts can be registered.
The following information can be registered as user information and host information.
Item | Description | Remarks |
|
|
|
User name | User name is to be registered to log in to the recorder. | This setting item can be configured only in |
| It will be required to log in to the recorder. | the user registration. |
|
|
|
IP address | IP address of a PC is to be registered to access the | This setting item can be configured only in |
| recorder. When "On" is set for "Host registration", only | the host registration. |
| PCs with the registered IP addresses can access the |
|
| recorder. |
|
Password | Password is to be registered to log in to the recorder |
| together with the user name. It will be required to log in |
| to the recorder. |
This setting item can be configured only in the user registration.
Level | Level indicates availability of the functions for users. |
| Refer to page 112 for the operable functions for each |
| level. |
Priority level | Priority level indicates the operational priority. When |
| multiple users/hosts tried to operate the same, only a |
| user/host with a higher priority can operate. |
In the following cases, the operational right will be given to a user/host with a higher priority.
•When another user tried to log in while the other user is already being logged in.
•When another user tried to control a camera that is being controlled by the other user
Default screen | Camera channels from which live images are to be |
| displayed on Monitor 1, Monitor 2 and the PC monitor |
| just after the login can be determined. |
|
|
Camera partitioning | Operational range of each camera channel for users/ |
| hosts can be determined. |
|
|
Users and hosts will be handled differently depending on how to access the recorder (between when the recorder is directly operated and when the recorder is operated via a network).
When operating the recorder directly
Operate the recorder while monitoring the monitor connected to the recorder. There are 3 ways of how to operate the recorder directly.
•Operate using the buttons on the front cover of the recorder.
•Operate using a mouse connected to the front cover of the recorder.
•Operate from a PS·Data compatible system controller.
Note:
•When controlling a camera connected to a coaxial communication unit from a system controller compatible with PS·Data, the priority level configured on the recorder will not be applied since it is controlled directly from the system controller. (The priority will be given to the latest operation.)
It is impossible to log in to the recorder from the front cover (using the buttons or the mouse) and from the system controller at the same time (except logging in using the same user name).It is impossible to log in to the recorder regardless of the priority level even if a user tried to log in when another user is already logged in.