Connection for the auto time adjustment function (1)
When "Master" is set for "Auto time adjustment" on the [Time & date] tab under the "Basic" page of the setup menu "Time adjustment signal output" becomes available and the clock of this recorder will be applied to other devices.
The time adjustment signal output will be generated from pin no. 20 (time adjustment I/O) at the time set for "Activation time"
(Signal ground)
(Time adjustment signal output)
13 20
ALARM/CONTROL
Terminal of the other device
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| input |
|
|
|
|
|
|
|
|
|
| Output for the |
|
|
|
|
|
|
| output |
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| Series recording output |
|
|
|
|
|
|
|
|
|
| indicators on |
|
|
|
|
|
|
| Series recording output | |||||||||||||||
|
|
|
| Sensor signal input |
|
|
|
|
|
| Time adjustment signal |
|
|
|
|
|
|
|
|
|
| the front panel |
|
|
| System error output | Thermal error output | Time adjustment signal | |||||||||||||||||||
| Signal ground | Alarm input | Alarm reset input | Signal ground | Alarm output | Alarm reset output | Alarm recording | During recording | Disk | Buzzer output | |||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Connection for the auto time adjustment function (2)
When "Slave" is set for "Auto adjustment time" on the [Time & date] tab under the "Basic"page of the setup menu
"Time adjustment signal input" becomes available and the clock of the other device will be applied to this recorder.
When a signal output from the other device is supplied to the time adjustment I/O terminals (pin no. 20) 15 minutes before/after the time set for "Activation time", the clock of the recorder will be set to the time set for "Activation time".
Example:
When "15:00" is set for "Activation time"
•Signal is supplied at 2:50:00 (hour:minute:second) pm → Set at 3:00:00 pm
•Signal input supplied at 3:14:45 pm → Set at 3:00:00 pm
•Signal is supplied at 3:20:00 pm → Time will not be adjusted.
Terminal of the other device
(Signal ground)
(Time adjustment signal output)
13 20
Signal ground
Sensor signal input
Alarm input
Alarm reset input
Series recording output
Time adjustment signal input
Signal ground
Alarm output
Alarm reset output
Output for the indicators on the front panel
Disk
During recording
Alarm recording
Buzzer output
System error output
Thermal error output
Time adjustment signal output
Series recording output
ALARM/CONTROL
Important:
• When "Slave" is selected, the clock will not be adjusted during event recording or emergency recording.